10
NEPTUNE 7 FA
1)
Options / model variants
Original instructions
EN
Connect the high pressure hose
quick connector to the high
pressure nipple located at right
rear of machine above chemical
tank.
1. Attach quick connect
adapter found with Owners
Manual to the water supply
hose.
2. Rinse the water supply
hose briefly in order to
prevent sand an other dirt
particles entering into the
machine.
3. Attach water supply hose
with adapter to inlet quick
connector.
4. Open water supply faucet.
3.9.2 Machines
without
high pressure hose
reel
1)
3.10
Connecting the water
supply
The machine is flushed with anti-freeze at the factory to protect it
against freezing; this mixture (approx. 5 l) may be captured in a
suitable container for reuse.
3.11
Antifreeze - before
first use
NOTE
•
See chapter 9.4 Technical Data for required quantity of water
and water pressure.
•
In the case of poor water quality (sand, etc.), it is recommen-
ded that an inlet water filter be installed.
•
Water supply hose should be a reinforced hose and have a
minimum inside diameter of 3/4” (19 mm).
CAUTION
•
Never operate the cleaner without water. Even brief shorta-
ges of water result in severe damage to the pump seals.