![Gerni 240A Hi-flow Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/gerni/240a-hi-flow/240a-hi-flow_operating-manual_2217228008.webp)
CHECK LIST
ACTION
WHAT/WHO
WHEN/HOW OFTEN
HOW
Instruct
New operator
Before operator uses
Let operator read
high pressure cleaner
instruction guide
Check
High pressure hose
During daily use
Leaks? - call
service engineer
Check
Pressure gauge
During daily use
Too high/too low? -
call service engineer
Check
Detergent suction
Daily - by means of
Lack of suction/leaks? -
detergent
call service engineer
Clean
Water filter
Weekly/as needed
See maintenance
Check
Gaskets
Every other month
Leaks? - call
service engineer
32
FAULTFINDING
SYMPTOMS
CAUSE
CORRECTIVE ACTION
High pressure cleaner
Switch not
Turn switch to pos. “1”.
does not start.
activated.
High pressure cleaner not
Insert the plug, switch on
connected to the power.
the main power supply.
Fuse burnt out.
Change fuse. If fuse burns out again,
contact service department.
High pressure cleaner
Fuse burnt out.
Change fuse. If fuse burns out again,
stops suddenly.
contact service department.
Low voltage.
Extension cable too long, or the
cable is underdimensioned
(please see survey).
Motor too warm.
Turn switch to pos. “0”
and wait 15 min. Restart the machine.
Operating pressure too high
Clean/change nozzle (see technical data).
(nozzle dirty, wrong nozzle).