Gerni 240A Hi-flow Скачать руководство пользователя страница 5

DESCRIPTION

29

Your new high pressure cleaner is constructed as shown in the
functional diagram and drawing No. 2. The machine consists of
an electric motor (2.1), which drives the high pressure pump
(2.2).
Through the water filter (2.4) the pump sucks the water from the
water inlet (2.3) into the cylinder head. The pump pressurises the
water and forces it out through the pressure outlet (2.5), into the
high pressure hose (2.6), to the pistol (2.7), and out through the
Turbo Laser nozzle (2.8).

The pressure of the high pressure cleaner can be read on the
pressure gauge (230A/250A/270A) (2.10). If the water pressure
exceeds the normal working pressure, the built-in safety valve
(2.12) will open the by-pass and thereby prevent damage to the
high pressure cleaner. 

When the pistol trigger is released, the motor will stop.
Detergent is added through the detergent hose from an external
tank. Adjustment of the concentration continues on the dosing
valve (2.15).

NB! When the high pressure cleaner is supplied with hot water
above 30°C, the pump must not suck water from a tank or the like,
but should be fed with pressure. At temperatures between 30 and
40°C, this pressure should be min.1 bar - between 40 and 60°C:
min. 3 bar.

2.1   Electric motor
2.2   Pump
2.3   Water inlet
2.4   Water filter
2.5   Pressure outlet
2.6   High pressure hose
2.7   Pistol
2.8   High pressure nozzle
2.9   Lance head
2.10  Pressure gauge (230A/250A/270A)
2.11  Micro switch
2.12  Safety valve
2.13  Detergent injector
2.14  Non-return ball valve
2.15  Dosing valve for detergent
2.16  Detergent hose
2.17  Switch (start/stop)

Placing of high pressure

hose/electric cable

Placing of detergent tank

Placing of additional lance

(Turbo Laser)

Placing of additional lance

(standard lance)

Placing of additional lance

(double lance)

FUNNCTIONS OF

THE DRIVING HANDLE

Besides functioning as holder for pistol and lance, more
holders are carrying for extra equipment on the driving
handle.

The holders can be used according to the illustrations
below.

Содержание 240A Hi-flow

Страница 1: ...svejledning side 2 DK Operating guide side 11 N Bruksanvisning Bruksanvisning sida 19 S page 27 GB Betreibsanleitung Seite 35 D Mode d emploi page 43 F Gebruiksaanwijzingen pagina 51 NL Instrucciones...

Страница 2: ...s R glementation machine 98 37 CEE R glementation CEM 89 336 CEE R glement basse tension 73 23 CEE R glement la mission acoustique 2000 14 EC NL Type 200 230 240 250 270 Deze machine is vervaardigd ov...

Страница 3: ...cessories To secure full benefit from your high pressure cleaner we ask you and other possible operators to study the following operating guide The operating guide should be regarded as an integral pa...

Страница 4: ...Use only Gerni A S Nilfisk high pressure hoses Do not use non Gerni Nilfisk high pressure hoses as they do not comply with the safety standards required by Gerni A S Never attempt to repair defective...

Страница 5: ...of the concentration continues on the dosing valve 2 15 NB When the high pressure cleaner is supplied with hot water above 30 C the pump must not suck water from a tank or the like but should be fed w...

Страница 6: ...more the N G 270 is provided with a handle for pressure regula tion and for application of detergents Starting If you require the high pressure cleaner to work with an action radius larger than its st...

Страница 7: ...ge of the oil filling hole for oil type and quantity please see the technical data Water filter Clean the water filter 2 4 as needed Dismount the hose screwed connection and remove the water filter Tu...

Страница 8: ...ervice engineer 32 FAULTFINDING SYMPTOMS CAUSE CORRECTIVE ACTION High pressure cleaner Switch not Turn switch to pos 1 does not start activated High pressure cleaner not Insert the plug switch on conn...

Страница 9: ...er Detergent filter dirty Clean filter Nozzle does not tilt Turbo Laser dirty Take apart and clean Turbo Laser Turbo Laser filter Clean change the filter see dirty maintenance Wrong nozzle Change nozz...

Страница 10: ...3 96 83 96 82 95 82 95 84 97 84 97 Dobbelt 1503 5 1503 1503 1503 5 1503 5 1504 1504 Dobbelt spuler 4040 4040 4040 4040 4040 4040 4040 4040 Dobbelt spul 15 40 15 40 15 40 15 40 15 40 15 40 15 40 El kab...