Gerni 240A Hi-flow Скачать руководство пользователя страница 6

OPERATING AND 

STARTING GUIDE

High pressure hose

Your new high pressure cleaner is equipped with a heavy duty
high pressure hose. Do not attempt to pull at the high pressure
hose when moving the high pressure cleaner. Be careful not to
run over or in any other way damage the high pressure hose. The
warranty does not cover broken hoses or hoses which have been
run over.

Fine sand filter

If you use water containing floating sand, we recommend that you
mount a fine sand filter. The filter element is changed according to
need. If a fine sand filter is not mounted, the fine sand may get in
the valves of the pump and cause damages on the safety valve,
cylinder head and possibly the Turbo Laser. This is not covered
by the guarantee.

Adjustable nozzle (N/G-230A/240A/250A)

The nozzle has three important functions:

1.

Operation at low pressure (with fluid detergent). 

To choose low pressure the head of the lance is pushed
away from the pistol (fig. a).

2.

Operation at high pressure (for powerful wash and rins-
ing).

To choose high pressure the head of the lance is pulled
towards the pistol (fig. b).

3.

Adjustment of the fan from concentrated (c) to fan-
shaped (d).    

Turbo Laser (N/G-250)  (N/G-230A 100/110V)

The high pressure cleaner is also equipped with a Turbo Laser
lance for highly improved cleaning efficiency (see technical data).

SPECTRUM

(N/G-270)

The high pressure cleaner is provided with a lance with a high
efficient high pressure 

SPECTRUM

nozzle which performs a

cleaning efficiency higher than traditional flat jet nozzles. Further-
more, the N/G-270 is provided with a handle for pressure regula-
tion and for application of detergents.

Starting

If you require the high pressure cleaner to work with an action
radius larger than its standard, you should lengthen the high pres-
sure hose and not the electric cable. If you still wish to extend the
electric cable the dimensions should be as follows: 

Length of cable

cross-sectional area

max. 12 m

min. 1.5 mm2

max. 20 m

min. 2.5 mm2

max. 30 m

min. 4.0 mm2

The high pressure cleaner must be situated as far away from the
cleaning site as possible.

1. 

Connect the electric cable. Note the rated voltage and
amperage of the high pressure cleaner :

Model

230

240

250

270

1x100V, 50/60Hz

14A

1x110V, 50Hz

13A

1x230/240V, 50Hz 10A

9,5

13/12A

1x230/240V, 60Hz

13/12A

3x230V, 50Hz

10.5A

3x400/415V, 50Hz

6A

2.

Connect the high pressure hose to the pressure outlet
(2.5). Flush the water supply hose through and connect it
to the water inlet (2.3). The hose must be min. 1/2”(N/G-
270: min. 3/4”).
The water supply pressure must be max. 10 bar during
operation.
Make sure the dosing valve (2.15) is in position “0”
(closed).
Turn on the water.

3..

Start the machine and let water run through the pistol.
Activate the pistol a few times and check that no air is
present in the system (when the water flow is steady and
not knocking). Then mount the lance on the pistol.

4

Activate the pistol (2.7) and let the high pressure cleaner
run till stable pressure is obtained (complete bleeding).
Now the high pressure cleaner is ready for use and by
means of the adjustable nozzle the raditation angle can
be adjusted (please see fig. c+d, page 8).
On the 

SPECTRUM

lance (N/G-270) and the Turbo Laser,

the pressure is regulated on the handle to the double
lance.

30

a

b

c

d

Содержание 240A Hi-flow

Страница 1: ...svejledning side 2 DK Operating guide side 11 N Bruksanvisning Bruksanvisning sida 19 S page 27 GB Betreibsanleitung Seite 35 D Mode d emploi page 43 F Gebruiksaanwijzingen pagina 51 NL Instrucciones...

Страница 2: ...s R glementation machine 98 37 CEE R glementation CEM 89 336 CEE R glement basse tension 73 23 CEE R glement la mission acoustique 2000 14 EC NL Type 200 230 240 250 270 Deze machine is vervaardigd ov...

Страница 3: ...cessories To secure full benefit from your high pressure cleaner we ask you and other possible operators to study the following operating guide The operating guide should be regarded as an integral pa...

Страница 4: ...Use only Gerni A S Nilfisk high pressure hoses Do not use non Gerni Nilfisk high pressure hoses as they do not comply with the safety standards required by Gerni A S Never attempt to repair defective...

Страница 5: ...of the concentration continues on the dosing valve 2 15 NB When the high pressure cleaner is supplied with hot water above 30 C the pump must not suck water from a tank or the like but should be fed w...

Страница 6: ...more the N G 270 is provided with a handle for pressure regula tion and for application of detergents Starting If you require the high pressure cleaner to work with an action radius larger than its st...

Страница 7: ...ge of the oil filling hole for oil type and quantity please see the technical data Water filter Clean the water filter 2 4 as needed Dismount the hose screwed connection and remove the water filter Tu...

Страница 8: ...ervice engineer 32 FAULTFINDING SYMPTOMS CAUSE CORRECTIVE ACTION High pressure cleaner Switch not Turn switch to pos 1 does not start activated High pressure cleaner not Insert the plug switch on conn...

Страница 9: ...er Detergent filter dirty Clean filter Nozzle does not tilt Turbo Laser dirty Take apart and clean Turbo Laser Turbo Laser filter Clean change the filter see dirty maintenance Wrong nozzle Change nozz...

Страница 10: ...3 96 83 96 82 95 82 95 84 97 84 97 Dobbelt 1503 5 1503 1503 1503 5 1503 5 1504 1504 Dobbelt spuler 4040 4040 4040 4040 4040 4040 4040 4040 Dobbelt spul 15 40 15 40 15 40 15 40 15 40 15 40 15 40 El kab...

Отзывы: