German pool GPS13 Series Скачать руководство пользователя страница 7

5

Operation Manual

14

Operation Manual

Cautions for using hot water

使用熱水注意事項

使用花灑沐浴前,請先用
手測試熱水溫度。

當使用熱水時,除使用者外,切勿讓
其他人調校熱水溫度。

When hot water is used, make sure 

that hot water temperature will not be  

changed by  persons other than user.

使用熱水器途中改變熱水溫度,有可能被熱水燙傷,
若熱水器使用途中被關掉,有可能導致受傷。

lf the hot  water temperature is changed in 

the middle of the use, you may get  burnt. lf 

the heater is  turned off in the middle  of the 

use,  you may have the risk to be injured.

當使用混合式水龍頭而同一個熱水系統
之另一個熱水龍頭開啟時,你可能會被
燙傷。

When the mixing tap is used, there 

may be a case that you will  get burnt 

if the other hot water tap in the same 

hot water piping system is opened.

If a mixing tap is used, close the hot water 

tap first.

若使用混合式水龍頭,切記將冷熱水選
擇杆推回原來位置。

When a mixing tap is used, make sure

to return the change over lever to the 

original position.

切勿在熱水器附近使用易燃物品,
如汽油、苯。

Do not use inflammable like gasoline and 

benzen near the heater.

可能引致生火。

A fire may be caused.

Make sure to check 

hot water temperature 

by hand before taking 

a shower.

可能被熱水燙傷。

You may be scalded by the hot water.

若使用混合式水龍頭,請先關掉熱水掣。

小心被熱水燙傷。

Caution: Prevent from getting burnt.

小心被熱水燙傷。

Caution: Prevent from getting burnt.

熱水供應可能隨時到達,請先用手測試後才使用。

Hot water may be supplied suddenly. Make sure to 

wait for a while and to check hot water temperature

by hand before use.

切勿為熱水器安裝檔冚。

Do not install a covering around the heater.

不正常燃燒可能導致生火或產生問題。

A fire or trouble of the heater may be caused by an

abnormal combustion.

Cautions for safety operations

安全操作注意事項

Please make sure to follow.

請確定遵從。

熱水掣關掉後,熱水管內仍存著熱水。
下次使用時,熱水管內熱水可能令你燙傷。

If a water tap is closed first, hot water will 

remain in the water piping system.You 

may get burnt by the hot water remained 

in the piping system in your next use.

若冷熱水選擇杆置於半開位置時,你可能
會被熱水燙傷。

You may get burnt by hot water if the lever 

is positioned in the half way.

WARNING

警告

檢查

1  

從泄壓閥拆除過濾網和磁鋼。

2  

用牙刷清洗過濾網,用清水沖洗磁鋼。

3  

安裝泄壓閥於入水口。

熱水器外表是否改變?

熱水器周圍是否有易燃物品?

Disassemble filter and magnetic steel 

from the pressure relief valve.

Use  toothbrush to clean the filter and

clean water for magnetic steel.

Install the pressure relief valve onto

the  water inlet.

Any abnormal operation sound?

Any changes on the appearance of 

the heater?

Any inflammables around the heater?

Inspection

保養

濾水器

Maintenance

Water filter

是否有異常之操作聲音?

數碼恒溫熱水爐具有兩種排氣方式,頂排式和背排式,其內部結構及使用性能相同,供客戶
選用。如上圖所示。

The water heaters have two types of gas exhaust  methods, top flue and back flue, the structures 

and operations of  the  heater is the same for customers choice. As shown in the above drawings.

依照下列程式定期進行日常檢查及保養。

保養前

預備工作

注意

關掉主氣體及冷熱水閥門,切斷電源供應及待熱水
器冷卻。

1  

關掉主開關。

2  

關掉主氣體及冷熱水閥門。

3  

切斷電源。

4  

熱水器冷卻後,進行下列步驟。

保養

熱水器

注意:切勿用苯或稀釋劑。

Carry out the daily inspection and maintenance regularly following the procedure described below.

Before maintenance

Preparations

Cautions

Close main gas and water valves, plug out power 

supply and wait until the heater is cooled down.

Turn off the main switch.

Close main gas and water valves.

Plug out power supply.

Carry out the following after the 

heater is cooled down.

Maintenance

Heater

Wipe the heater with swab or towel using 

a kitchen cleanser.

Note: Do not use benzen and thinner.

用刷掃或毛巾加廚房清潔液揩抹熱水器。

Daily inspection and maintenance

日常檢查及保養

13

Operation Manual

6

Operation Manual

緊固地插入。

熱水器可能有問題。

間中清潔電源插的塵埃。

若電源插積聚塵埃,潮濕導致絕緣降低而可能引致生火。

切勿破壞電源線及電源插。

若使用損壞的電線及電源插,可能導致觸電,短路及生火。

確定電路不超載。

若超載,可能生熱而導致生火。

手部帶有水份切勿觸摸電插頭。

可能導致觸電。

當插入或拔出電源,確定拿緊電插頭。

若拔出或拉出電源線,電源線可能脫離而導致生火或觸電。

若使用不正確安裝或搬遷的熱水器,損壞的電源線及電源插,
可能導致觸電,短路及生火。

Plug in firmly.

The heater may be malfunctioned.

Remove dusts on the plug occasionally.

If any dust gathered on the plug, the electrical insulation 

becomes poor due to humidity and may cause a fire.

Do not damage power cord and plug.

If damaged cord or plug is used, electric shock, 

short-circuit and a fire may be caused.

Make sure that wiring equipment should 

not be overloaded.

If overloaded, it may generate heat to cause a fire.

Do not touch an electric plug with wet 

hands.

An electrical shock may be caused.

When power supply is plugged in or out, make 

sure to do so by holding the plug firmly.

If you plug out by pulling the power cord, power cord 

may be disconnected to cause a fire or an electric shock.

Installation or relocation of the heater must 

be done by a Registered Gas Installer.

If the heater is not installed properly,electric 

shock, short-circuit or a fire or a trouble may 

be caused.

熱水器之安裝或搬移,必須由註冊氣體
技工進行。

WARNING

警告

Содержание GPS13 Series

Страница 1: ...Instantaneous Gas Water Heater...

Страница 2: ...ooting of the heater 17 Specifications 18 Repair service 9 Parts identifications 51 For Use in Hong Kong It is an offence under the Gas Safety Registration of Gas lnstallers and Gas Contractors Regula...

Страница 3: ...ry is expected This marking is labeled on those items that any injury and material damage is expected The below listed markings are used in the operation manual This marking is given to those items to...

Страница 4: ...mpany Do not turn on off the electrical switches or ignite fire No fire A fire or an explosion may be caused Do not install the heater outdoors When the flue duct is removed or clogged the exhaust air...

Страница 5: ...If one of above 1 5 devices is activated close main gas and water valves and call the dealer Error Code E0 Outlet Water Detector Failure E1 Ignition Failure E2 False Fire Failure E3 Temperature Contr...

Страница 6: ...l position Do not use inflammable like gasoline and benzen near the heater A fire may be caused Make sure to check hot water temperature by hand before taking a shower You may be scalded by the hot wa...

Страница 7: ...the plug occasionally If any dust gathered on the plug the electrical insulation becomes poor due to humidity and may cause a fire Do not damage power cord and plug If damaged cord or plug is used el...

Страница 8: ...ire or an injury Make sure to close main gas and water valves to plug out the heater and to confirm the heater is cooled down before inspection and maintenance Make sure to confirm that the heater is...

Страница 9: ...n or off the heater which according to the setting temp Main and vice controller both with the self memory function and could showing the last set temp When the controller get the priority it will sho...

Страница 10: ...are auto regulating gas flow effect of water flow to achieve automatic thermostat So at the time of testing the load may fall short of the maximum heat load Methods for detection of maximum heat load...

Страница 11: ...tap is opened when the lever is up explanation as follows To operate the heater for the first time 10 Operation Manual To confirm gas supply and power supply Open hot water tap Open to flow out water...

Страница 12: ...e by pressing or button of the control panel the water flow out will gradually reach the temperature you desired after 10 seconds Operating Instructions ON OFF button HOTTER button Error code display...

Страница 13: ...n or off the heater which according to the setting temp Main and vice controller both with the self memory function and could showing the last set temp When the controller get the priority it will sho...

Страница 14: ...valves plug out power supply and wait until the heater is cooled down Turn off the main switch Close main gas and water valves Plug out power supply Carry out the following after the heater is cooled...

Страница 15: ...the power cord power cord may be disconnected to cause a fire or an electric shock Installation or relocation of the heater must be done by a Registered Gas Installer If the heater is not installed pr...

Страница 16: ...as valve opened fully Is main water valve opened fully Is there a suspension of the water supply Is there a power failure Is there air left in the piping system Repeat ignition procedures Is main gas...

Страница 17: ...l This happens when water in the exhaust air becomes vapor Fan rotating sound is heard after hot water supply is stopped Hot water becomes cloudy when hot water tap is closed slightly It is only becau...

Страница 18: ...al lnstallation manual Screws 0 02 0 8MPa 0 2 8kgf cm2 25kPa 0 25kgf cm2 heater heater Maximum AC220V 50Hz Flame failure device Lightening surge protector Overheat prevention device Hot water hi limit...

Страница 19: ...ry is expected This marking is labeled on those items that any injury and material damage is expected The below listed markings are used in the operation manual This marking is given to those items to...

Страница 20: ...757 2980 8318 3 F Takshun Plaza Nanguo East Road Shunde Foshan Guangdong 263 15 I Alameda Dr Carlos D Assumpcao No 263 Edif China Civil Plaza 15 Andar I Macau Tel 853 2875 2699 Fax 853 2875 2661 Macau...

Отзывы: