German pool GPS13 Series Скачать руководство пользователя страница 10

9

Operation Manual

10

Operation Manual

確定氣體供應及
電力供應。

開啟熱水掣。

開啟讓水排出。

關掉熱水掣。

插入電源插。

To confirm gas supply 

and power supply.

Open hot water tap.

Open to flow out water.

Close the tap.

Plug in power plug.

1

2

開啟主水閥門。

開啟主氣體閥門。

Open main water 

valve.

Open  main gas 

valve.

確定有水流出。

To confirm water 

comes out.

1

2

通電顯示幕中“         ”燈亮,開水時機器點火及風機轉動,顯示幕中的“              ”
燈亮,機械正常工作。

When there is power supply, the lamp of "                    " at display will be on.Then turn on the water,
and the heater ignition and the blower running will be started at same time, then the "                           " 
on display will be on.

以下解釋推捍拉起後熱水掣便開啟。

Hot water tap is opened when the lever is up, explanation as follows.

Parts identifications

各部份名稱

To operate the heater for the first time

第一次使用熱水器

顯示幕

Temperature display

出水口

Water outlet

進水口

Water inlet

泄壓閥

Pressure relief valve

熱水爐最大熱負荷檢測方法

開關鍵

ON/OFF button

熱鍵

HOTTER button

冷鍵

COOLER button

因GPS13恒溫式燃氣快速熱水爐是自動調節燃氣流量、水流量以達到自動恒溫的效果,所以,在檢
測時,其負荷可能達不到最大熱負荷。

檢測最大熱負荷的方法:按“開/關”鍵,關機,自動調水閥自動重定至最大水流量狀態。打開面
殼,拔除自動調水閥接外掛程式,使其停止工作。然後蓋上面板,按恒溫機檢測方法檢測最大熱
負荷。

Water heater maximum heat load measurement method

Thermostat type gas instantaneous hot water heaters in this series are auto-regulating gas flow, 

effect of water flow to achieve automatic thermostat. So, at the time of testing, the load may fall 

short of the maximum heat load.

Methods for detection of maximum heat load:

Press the on/off switch, shutdown, automatic water valve automatically reset to the maximum water 

flow condition. Open the panel, removal of auto-valve connectors, make it stop working. Then close 

the Panel. Constant temperature detection method for detection of maximum heat load.

Содержание GPS13 Series

Страница 1: ...Instantaneous Gas Water Heater...

Страница 2: ...ooting of the heater 17 Specifications 18 Repair service 9 Parts identifications 51 For Use in Hong Kong It is an offence under the Gas Safety Registration of Gas lnstallers and Gas Contractors Regula...

Страница 3: ...ry is expected This marking is labeled on those items that any injury and material damage is expected The below listed markings are used in the operation manual This marking is given to those items to...

Страница 4: ...mpany Do not turn on off the electrical switches or ignite fire No fire A fire or an explosion may be caused Do not install the heater outdoors When the flue duct is removed or clogged the exhaust air...

Страница 5: ...If one of above 1 5 devices is activated close main gas and water valves and call the dealer Error Code E0 Outlet Water Detector Failure E1 Ignition Failure E2 False Fire Failure E3 Temperature Contr...

Страница 6: ...l position Do not use inflammable like gasoline and benzen near the heater A fire may be caused Make sure to check hot water temperature by hand before taking a shower You may be scalded by the hot wa...

Страница 7: ...the plug occasionally If any dust gathered on the plug the electrical insulation becomes poor due to humidity and may cause a fire Do not damage power cord and plug If damaged cord or plug is used el...

Страница 8: ...ire or an injury Make sure to close main gas and water valves to plug out the heater and to confirm the heater is cooled down before inspection and maintenance Make sure to confirm that the heater is...

Страница 9: ...n or off the heater which according to the setting temp Main and vice controller both with the self memory function and could showing the last set temp When the controller get the priority it will sho...

Страница 10: ...are auto regulating gas flow effect of water flow to achieve automatic thermostat So at the time of testing the load may fall short of the maximum heat load Methods for detection of maximum heat load...

Страница 11: ...tap is opened when the lever is up explanation as follows To operate the heater for the first time 10 Operation Manual To confirm gas supply and power supply Open hot water tap Open to flow out water...

Страница 12: ...e by pressing or button of the control panel the water flow out will gradually reach the temperature you desired after 10 seconds Operating Instructions ON OFF button HOTTER button Error code display...

Страница 13: ...n or off the heater which according to the setting temp Main and vice controller both with the self memory function and could showing the last set temp When the controller get the priority it will sho...

Страница 14: ...valves plug out power supply and wait until the heater is cooled down Turn off the main switch Close main gas and water valves Plug out power supply Carry out the following after the heater is cooled...

Страница 15: ...the power cord power cord may be disconnected to cause a fire or an electric shock Installation or relocation of the heater must be done by a Registered Gas Installer If the heater is not installed pr...

Страница 16: ...as valve opened fully Is main water valve opened fully Is there a suspension of the water supply Is there a power failure Is there air left in the piping system Repeat ignition procedures Is main gas...

Страница 17: ...l This happens when water in the exhaust air becomes vapor Fan rotating sound is heard after hot water supply is stopped Hot water becomes cloudy when hot water tap is closed slightly It is only becau...

Страница 18: ...al lnstallation manual Screws 0 02 0 8MPa 0 2 8kgf cm2 25kPa 0 25kgf cm2 heater heater Maximum AC220V 50Hz Flame failure device Lightening surge protector Overheat prevention device Hot water hi limit...

Страница 19: ...ry is expected This marking is labeled on those items that any injury and material damage is expected The below listed markings are used in the operation manual This marking is given to those items to...

Страница 20: ...757 2980 8318 3 F Takshun Plaza Nanguo East Road Shunde Foshan Guangdong 263 15 I Alameda Dr Carlos D Assumpcao No 263 Edif China Civil Plaza 15 Andar I Macau Tel 853 2875 2699 Fax 853 2875 2661 Macau...

Отзывы: