2.  To connect the sensor to the GV-AS400, connect the 

Red

 wire of the sensor to the 

Input

 

of the GV-AS400, and connect the 

Black 

wire of the sensor to the 

Ground

 of the GV-

AS400. 

      

 

 

3.  On the Web interface of the GV-AS400, select 

Input Setting

, and select an input type 

and input function for the connected sensor from the electromagnetic lock.      

Input Type

Input Function

 

4.  On the Web interface of the GV-AS400, select 

Output Setting

, and select an output type 

and output function for the connected electromagnetic lock.      

 

For details on configuring the input and out devices, see 

3.4.3.D Input Function

 and 

3.4.3.E 

Output Function

 on the GV-AS Controller User’s Manual. 

 

 

 

 

May 13, 2011 

 

6

Specifications 

Voltage 

DC 12V / 24V 

Current  

500mA at 12V / 250mA at 24V 

Holding Force 

272.15 kg / 600 lb 

Dimension (L x W x H) 

250 x 47.2 x 26.6 mm / 9.84 x 1.86 x 1.05 in                     

Armature Plate Dimension      
(L x W x H) 

185 x 38 x 12.5 mm / 7.28 x 1.50 x 0.49 in 

Certification 

CE and UL 

 