2.  Mounts the armature plate to the door. 

      

 

Typical Installation of the electromagnetic lock: 

 

      

 

 

Note: 

To make the armature plate adjust its proper position to the magnet automatically, 

do not fix the armature plate too tightly and make the rubber washer more flexible. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

May 13, 2011 

 

4

Contacts 

Unscrew the cover of electromagnetic lock and you will see the diagram as below: 

 

 

1. 

Power Terminal Block:

 Connects to the DC 12V / 24V power source.  

2. 

Power Switch Jumper:

 Plug the power jumpers to 

Pins 1, 2

 and 

Pins 3, 4

 for a 12V 

DC power source. Plug the power jumper to 

Pins 2, 3

 for a 24V DC power source. 

3. 

Sensor: 

Connects to the access control system by using the black and red wires. For 

details, see Connecting Sensor to the Access Control System later in this installation 
guide. 

 

Connecting to the GV-AS Controller 

To connect the electromagnetic lock to the GV-AS Controller, follow the steps below. Here 

we use the GV-AS400 Controller for example. 

 

1.  To connect the power between the electromagnetic lock and the GV-AS400, refer to the 

diagram as below. 

      

 

Connect the (+) point on the electromagnetic lock to 

COM

 on GV-AS400, connect the 

two (-) points of the electromagnetic lock and the external power supply together, and 

connect the (+) point on the external power supply to 

NC

 on GV-AS400. 

 

 