Read and follow all U.L. and Safety Standards before installing any access device.  Please refer to this manual and 
qualified personnel for assistance.  DO NOT install this device unless all entrapment and pinch points are eliminated. 

Revision 1.6A   

DL1000 

Standalone Digital Lock 

Product Manual 



Installation Instructions 



Program Instructions 

Summary of Contents for DL1000

Page 1: ...cess device Please refer to this manual and qualified personnel for assistance DO NOT install this device unless all entrapment and pinch points are eliminated 1 Revision 1 6A DL1000 Standalone Digita...

Page 2: ...e Entry Codes 6 Add Single Customized Codes 7 Delete Single Entry Codes 8 Add Simple Block Entry Codes 8 Add Block Customized Codes 8 Delete Block Entry Codes 9 Auxiliary Input Programming 9 Entry Cod...

Page 3: ...feature to prevent unauthorized use 8 Mount all operating devices clearly out of reach of through gates 9 DO NOT install this device unless all potential hazards and pinch points have been eliminated...

Page 4: ...the system to a gate operator 1 Connect NO1 to Gate Open Input 2 Connect COM1 to Gate Common 3 Use at least 18AWG or larger wire 4 Important Follow all safety guidelines and precautions when using the...

Page 5: ...ol To connect to the Auxiliary Override inputs To activate Relay 1 1 Connect COM to the open device 2 Connect EXIT 1 to the open device To activate Relay 2 1 Connect COM to the open device 2 Connect E...

Page 6: ...number and PAC Serial Number Program Access Code PROGRAMMING Time Clock Programming The DL1000 has a built in 7 Day Plus time clock for time control of individual codes and relay open schedules Codes...

Page 7: ...Press or for active days of week All days Example 1 Sunday 246 MWF PROGRAMMING Add Single Customized Code Cont 21 Press or for start time 12 00 00 Time is 12 hour format 22 Press for AM PM setting 1...

Page 8: ...ize an entry code settings program each step as needed To program a customized block of codes 1 Press and hold for 3 seconds STATUS 2 Press PAC PROGRAM 3 Press CODE 4 Press START 5 Press starting code...

Page 9: ...nput Programming This programming will set the Relay Functions Event Control and Do Not Disturb DND control of the Auxiliary Inputs All external devices fire boxes key boxes pushbuttons connected to t...

Page 10: ...ET 5 Press to confirm All codes will be cleared 6 Press to exit Turn power off on to reset PROGRAMMING Strikes Lockout Programming Strikes Lockout helps prevent unauthorized users from using multiple...

Page 11: ...AM 2 PM 14 Press or for end time 12 00 00 Time is 12 hour format 15 Press for AM PM setting 1 AM 2 PM 16 Press or 1 6 for Relay 2 Function None 17 Press or 1 2 for Relay 2 Event Control Off 18 Press o...

Page 12: ...lock Time Date 1 Press Displays Clock Date Time 2 Press to return to Welcome screen WELCOME OPERATING INSTRUCTIONS Do Not Disturb DND Feature The Do Not Disturb DND mode puts the system into a sleep m...

Page 13: ...uts 1 Strikes Lockout feature may be active Wait 3 minutes and retry 2 Make sure the keypad is plugged in correctly Entry Codes will not activate relay 1 Enter the entry code slower A beep should soun...

Page 14: ...can cause serious injury or death Read and follow all installation manuals reference manuals and warning label instructions 2 Vehicular gates are for vehicles only Pedestrians must use a separate entr...