![GeoVision GV-POE0812 Скачать руководство пользователя страница 266](http://html1.mh-extra.com/html/geovision/gv-poe0812/gv-poe0812_user-manual_2216057266.webp)
this server.
Status
The current status of the server. This field takes one of the following values:
Disabled:
The server is disabled.
Not Ready:
The server is enabled, but IP communication is not yet up and
running.
Ready:
The server is enabled, IP communication is up and running, and the
RADIUS module is ready to accept accounting attempts.
Dead (X seconds left):
Accounting attempts were made to this server, but it
did not reply within the configured timeout. The server has temporarily been
disabled, but will get re-enabled when the dead-time expires. The number of
is enabled.
seconds left before this occurs is displayed in parentheses. This state is only
reachable when more than one server
Buttons
Auto-refresh:
Check this box to refresh the page automatically. Automatic
refresh occurs every 3 seconds.
Refresh:
Click to refresh the page immediately.
258