3. Check for proper function of the probe. Using an ohm meter on the R x 1 scale, the following pins
should read electrically as follows:
A-B
Closed when Tankfull float is down.
A-B
Open when Tankfull float is up.
E
From pin E to any metal part of the probe there should be continuity.
Any deviation from this test means the probe is faulty. Contact Geotech (1-800-833-7958) for
assistance.
Additional problems can occur if the intake is not checked for blockage and the probes are not regularly
cleaned.