12
Option A: With no water pump:
This situation will produce very slow recovery rates unless there is considerable product layer. The best
location for the probe is slightly below the middle of the product layer.
To deploy and start the system, lower the intake/probe assembly into the well, confirm that the output hose is
secured at the recovery tank and turn the control switch to AUTO. Assuming that sufficient product is present
in the well, the SWPS will begin pumping.
Option B: With independent water pump:
In this option, the water pump is used to depress the water table and thereby concentrate product in the well.
Since the water and product pumps are operating independently, any change in the level of the water table will
require adjustment of the pump intakes in the well.
The water alarm indicator is useful in determining when adjustment of the intake is necessary. When the intake
assembly is set too deep, the red light will illuminate indicating that the water float is under water. If set too
shallow, there will be no signal.
When using a water pump with the SWPS, the water pump must be deployed first. Follow the instructions
found in the Water Table Depression Pump User Manual (included with WTDP assemblies). After the water
pump has been deployed and a pumping level established, deploy the SWPS as described in Option A.