![Geotech Shallow Well Probe Scavenger Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/geotech/shallow-well-probe-scavenger/shallow-well-probe-scavenger_installation-and-operation-manual_2215610011.webp)
9
Place the Intake Assembly and Product Probe in the well
Use a Geotech Interface Probe to determine the product layer thickness, depth, and recharge rate. Use this
measurement to properly place the intake (with probe attached) into the well or collection point. Prior to
installing the intake assembly, determine if any adjustments are needed to the PCM’s potentiometer to match
the recharge rate of the well. See Float Time Delay later in this section.
Water Table Depression Pump (WTDP)
If the water table continues to fluctuate as such that water float rises and turns off the PCM often, then it may
be necessary to install a WTDP pump with probe to keep the water table level. Contact Geotech to discuss
alternatives to well recovery with a fluctuating water table.
PCM Controls
The SWPS controls consist of the electronics in the control module (Figure 2-1), the product pump and motor,
the product probe and the Tankfull probe (see also Figure 7-1 for an example of a standard system
configuration.)
Figure 2-1
: SWPS Control Module with Pump and Motor
The control system provides the user with many options for optimal recovery. It is rated explosion proof for
class I, division I, Group D hazardous locations and meets with intrinsic safety standards.
Содержание Shallow Well Probe Scavenger
Страница 1: ...Rev 7 12 2018 Part 16030005 Shallow Well Probe Scavenger Installation and Operation Manual...
Страница 2: ......
Страница 20: ...18 Figure 6 1 Intake Specifications...
Страница 21: ...19 Section 7 System Schematic Figure 7 1 Standard System Assembly...
Страница 30: ...28 NOTES...