Section 2: System Installation
The Geotech Filter Bucket is placed in a sump, pond, or other body of water. It is easily
deployed by holding the circumferential handle. The bucket and cartridge will float as
shown in Figure 3-1. As it progressively fills, the bucket will sink into the water while the
cartridge will remain at the water/product interface (Figure 3-3).
When the bucket is full, remove it by its handle. Unscrew the cover and pour the product
into a suitable receptacle. Clean any debris off the cartridge exterior if necessary.
The cartridge surface is best cleaned with a soft brush and clean
fuel. Care should be taken to remove debris without pushing it
through the screen. Never clean with detergents, surfactants, or
unknown solvents.
If the Filter Bucket is left floating on water with little or no hydrocarbon
present; the screen may eventually pass water and cause the bucket to
sink. As a precaution against this possibility, tether the bucket by
attaching a cord to the lifting handle. Attach the other end of the cord to
the edge of the well or pond.