Geotech EcoSense EC300A Скачать руководство пользователя страница 2

WARRANTY

The EcoSense® EC300A/EC300M Instrument is warranted for one year 
from date of purchase by the end user against defects in materials 
and workmanship. EC300A/EC300M probes and cables are warranted 
for one year from date of purchase by the end user against defects in 
material and workmanship. Within the warranty period, YSI will repair 
or replace, at its sole discretion, free of charge, any product that YSI 
determines to be covered by this warranty. 

To exercise this warranty, write or call your local YSI representative, 
or contact YSI Customer Service in Yellow Springs, Ohio. Send 
the product and proof of purchase, transportation prepaid, to the 
Authorized Service Center selected by YSI. Repair or replacement will 
be made and the product returned, transportation prepaid. Repaired 
or replaced products are warranted for the balance of the original 
warranty period, or at least 90 days from date of repair or replacement. 

Limitation of Warranty 

This Warranty does not apply to any YSI product damage or failure 
caused by: (i) failure to install, operate or use the product in accordance 
with YSI’s written instructions; (ii) abuse or misuse of the product; 
(iii) failure to maintain the product in accordance with YSI’s written 
instructions or standard industry procedure; (iv) any improper repairs 
to the product; (v) use by you of defective or improper components or 
parts in servicing or repairing the product; or (vi) modification of the 
product in any way not expressly authorized by YSI.

THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED 
OR IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY 
OR FITNESS FOR A PARTICULAR PURPOSE. YSI’s LIABILITY UNDER 
THIS WARRANTY IS LIMITED TO REPAIR OR REPLACEMENT OF THE 
PRODUCT, AND THIS SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY 
FOR ANY DEFECTIVE PRODUCT COVERED BY THIS WARRANTY. 
IN NO EVENT SHALL YSI BE LIABLE FOR ANY SPECIAL, INDIRECT, 
INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM 
ANY DEFECTIVE PRODUCT COVERED BY THIS WARRANTY

Contact Information

YSI
1725 Brannum Lane
Yellow Springs OH, 45387, USA
Tel: 800-897-4151 • 937-767-7241; Fax: 937-767-1058
E-mail: [email protected]
Web: ysi.com

606042REF-B-EC300A-EC300M-Manual-English.indd   2

12/11/2017   10:07:39 AM

Содержание EcoSense EC300A

Страница 1: ...USER MANUAL English Fran ais Espa ol Portugu s EcoSense EC300A EcoSense EC300M Portable Conductivity Salinity and Temperature Instruments User Manual DOCUMENT 606042REF...

Страница 2: ...amage or failure caused by i failure to install operate or use the product in accordance with YSI s written instructions ii abuse or misuse of the product iii failure to maintain the product in accord...

Страница 3: ...t Modes 6 Calibration 7 TDS 7 CELL 7 Temperature Coefficient 8 Temperature Reference 8 Conductivity Calibration 8 Conductivity Measurements 8 Saving Viewing and Deleting Data 9 Downloading Data to a C...

Страница 4: ...Accessories Part Numbers 14 Technical Services 14 Specifications 14 606042REF B EC300A EC300M Manual English indd 4 12 11 2017 10 07 39 AM...

Страница 5: ...l contaminants that may affect probe connections 3 Wait for unit and all connections to dry before reinstalling the battery and resuming operation 4 If the unit does not function correctly after step...

Страница 6: ...attery cover and o ring Figure 1 Replace the 9V battery Replace the battery cover and o ring be sure to align the o ring correctly to prevent a bad seal and fasten the two battery cover screws Battery...

Страница 7: ...vailable with a single four electrode cell Other features include automatic conductivity ranging automatic temperature compensation long battery life and 50 60 Hz AC noise rejection This meter is univ...

Страница 8: ...ction indicator EC300M only 8 Displays when measuring salinity 9 Calibration mode indicator 10 Data set number 11 Temperature display 12 Indicates TDS measurement 13 Indicates conductivity measurement...

Страница 9: ...oSense Mode CAL Recal Timer Date Time Up and down arrow keys Increases or decreases the display value as desired 3 DO200M INPUT EcoSense Mode CAL Recal Timer Date Time Calibration key Press to enter t...

Страница 10: ...confirms calibration steps and confirms data deletion On the EC300M this key confirms recal timer entry and date time selections 8 YSI EcoSense Handheld Overlay 12 19 2016 DO200M colors Black backgrou...

Страница 11: ...quentially display the following sections Note Press Enter to accept any values changes in each section and automatically advance to the next section If there are no changes the unit accepts the curre...

Страница 12: ...in a standard of known conductivity preferably a standard in the middle range of the solutions to be measured Completely submerge the probe without touching the sides of the calibration container Shak...

Страница 13: ...ice to return to the measurement mode If Each is selected the Up and Down arrow keys will allow you to scroll through the saved data records Press Enter to delete the selected record All records after...

Страница 14: ...urn to the run screen Any value between 0 and 60 days can be selected Set the value to 0 to disable the Recal Timer Date Time Settings EC300M Only A short press i e key is not held of the Date Time ke...

Страница 15: ...for service Undr Temperature 10 0 C Opening the Data File with Excel Depending on the region and language setting of your PC measurement data might be formatted incorrectly by Excel when the data fil...

Страница 16: ...t Wizard choose Delimited 5 Under Step 2 of the Text Import Wizard choose Semicolon 6 Under Step 3 click on the column with the incorrectly formatted data This column should be highlighted in black Ch...

Страница 17: ...1 Dip the cell in cleaning solution and agitate for two to three minutes Any foaming acid tile cleaner such as Dow Chemical Bathroom Cleaner should clean adequately For a stronger cleaner use a soluti...

Страница 18: ...com S P E C I F I C AT I O N S These specifications represent typical performance and are subject to change without notice For the latest product specification information please visit YSI s website a...

Страница 19: ...ure 0 to 50 C 32 to 122 F Operating Range Relative Humidity Up to 95 Instrument Casing Waterproof IP 67 with cable connector cap installed Weight with battery 272 grams 6 lbs Dimensions L x W x H 18 7...

Страница 20: ...2013 IEC 61326 1 2012 IEC 61000 3 2 2005 IEC 61000 3 3 2008 IEC 61000 4 2 2008 IEC 61000 4 3 2006 IEC 61000 4 4 2004 IEC 61000 4 6 2008 IEC 61000 4 8 2009 Item 606042REF Revision B December 2017 For t...