![Geometrics G-877 Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/geometrics/g-877/g-877_operation-manual_2214706038.webp)
fid display position(0=none,1=1st, 2=2nd, .. etc) : 0
fid display format :#####
signal display position(0=none,1=1st, 2=2nd, .. etc) : 2
signal display format :####
depth display position(0=none,1=1st, 2=2nd, .. etc) : 3
depth display format :###.##
input voltage display position(0=none,1=1st, 2=2nd, .. etc) : 5
input voltage display format :##.#
temperature display position(0=none,1=1st, 2=2nd, .. etc) : 0
temperature display format :####
polarize voltage display position(0=none,1=1st, 2=2nd, .. etc) : 0
polarize voltage display format :####
tuning display position(0=none,1=1st, 2=2nd, .. etc) : 4
tuning display format :###.#
Status display position(0=none,1=1st, 2=2nd, .. etc) : 0
Status display format :##
Postamble :\N
Baud rate : 9600
Cable length in feet : 2.0
Capacitance per foot in pF : 25.0
Sensor inductance in mH : 55.8
(the following sections are under factory password control. Contact Factory
if you need to access these parts of the firmware)
Password :
Gate time as percent of cycle time : 50.0
Maximum gate time in seconds : 0.5
Maximum pol time : 5.0
auto tuning search increment in Kgammas : 2.0
Bad readings before auto tuning searches : 3
Max change in auto tuning per reading in kilo gammas : 5.0
Minimum accepted signal for auto tuning :200
When in configure mode turn pol. (0=OFF,1=ON) : 0
Trigger character :=
Lump capacitance in nF : 26.5
C[01] in nF : 3.0
C[02] in nF : 5.5
C[04] in nF : 13.9
C[08] in nF : 24.0
C[10] in nF : 54.5
C[20] in nF :114.4
C[40] in nF :218.1
C[80] in nF :442.3
Pol to connect delay in mS : 5.0
Connect to damp delay in mS : 4.0
Damp to deQ delay in mS : 2.0
de-Q to gate delay in mS : 40.0
IPP Time-out delay in mS : 20.0
signal scale factor : 1
signal bias sign (0 = add, 1=subtract) :0
signal bias : 0
signal decimals :0
depth scale factor : 595
depth bias sign (0 = add, 1=subtract) :1
depth bias : 832
depth decimals :4
input voltage scale factor : 145
input voltage bias sign (0 = add, 1=subtract) :0
input voltage bias : 0
38
G–877 MARINE MAGNETOMETER OPERATION MANUAL
Содержание G-877
Страница 2: ...2 G 877 MARINE MAGNETOMETER OPERATION MANUAL...
Страница 4: ...4 G 877 MARINE MAGNETOMETER OPERATION MANUAL...
Страница 8: ...NOTES 8 G 877 MARINE MAGNETOMETER OPERATION MANUAL...
Страница 17: ...NOTES G 877 MARINE MAGNETOMETER OPERATION MANUAL 17...
Страница 32: ...NOTES 32 G 877 MARINE MAGNETOMETER OPERATION MANUAL...