Zoom80
| 42
Technical Data
Automatic corrections
The following automatic corrections are made:
7.1.2
Angle Measurement
Accuracy
Characteristics
Absolute, continuous, diametric.
7.1.3
Distance Measurement with Reflectors
Range
Atmospheric conditions
Measurements can be made to reflector tapes over the entire range without external ancillary optics.
Accuracy
Accuracy refers to measurements to standard prisms.
Beam interruptions, severe heat shimmer and moving objects within the beam path can result in devia-
tions of the specified accuracy.
The display resolution is 0.1 mm.
Characteristics
•
Line of sight error
•
Vertical index error
•
Tilting axis error
•
Standing axis tilt
•
Earth curvature
•
Refraction
•
Circle eccentricity
•
Aim360 zero point error
•
Compensator index error
Type
std. dev. Hz, V, ISO 17123-3
Display least count
["]
[mgon]
["]
[mgon]
Zoom80 S/R
1
0.3
0.1
0.1
Zoom80 S/R
2
0.6
0.1
0.1
Zoom80 S/R
5
1.5
0.1
0.5
Reflector
Range A
Range B
Range C
[m]
[ft]
[m]
[ft]
[m]
[ft]
Circular prism
1800
6000
3000
10000
3500
12000
3 prisms
2300
7500
4500
14700
5400
17700
360° prism
800
2600
1500
5000
2000
7000
360° Mini prism
450
1500
800
2600
1000
3300
Mini prism
800
2600
1200
4000
2000
7000
Reflective tape
60 mm x 60 mm
150
500
250
800
250
800
Shortest measuring distance:
1.5 m
Range A:
Strong haze, visibility 5 km; or strong sunlight, severe heat shimmer
Range B:
Light haze, visibility about 20 km; or moderate sunlight, slight heat shimmer
Range C:
Overcast, no haze, visibility about 40 km; no heat shimmer
EDM
measuring mode
std. dev. ISO 17123-4,
standard prism
std. dev. ISO 17123-4,
tape
Measurement time,
typical [s]
Standard
1 mm + 1.5 ppm
5 mm + 2 ppm
2.4
Fast
3 mm + 1.5 ppm
5 mm + 2 ppm
0.8
Tracking
3 mm + 1.5 ppm
5 mm + 2 ppm
< 0.15
Principle:
Phase measurement
Type:
Coaxial, visible red laser
Carrier wave:
658 nm
Measuring system:
System analyser basis 100 MHz - 150 MHz
Содержание Zoom80 R