Check & Adjust
Combined adjustment
procedure step-by-step
The following table explains the most common settings.
Next step
Step
Description
1.
Main Menu: Tools...
\
Check & Adjust...
2.
TOOLS Check & Adjust Menu
Select the option: Combined (l,t,i,c,Aim)
3.
TOOLS Combined I
<Aim Adjust: On> Includes the determination of the Aim360 Hz and V adjustment errors.
It is recommended to use a clean GeoMax circular prism as target. Do not use a 360°
prism.
4.
Aim the telescope accurately at a target at about 100 m
distant. The target must be positioned within ± 9°/± 10 gon
of the horizontal plane.
The procedure can be started in any telescope face.
5.
MEAS
(F1) to measure and to continue to the next screen.
Instruments change automatically to the other face.
The fine pointing has to be performed manually in both
faces.
6.
TOOLS Combined II
MEAS
(F1) to measure the same target in the other face and to calculate the instrument
errors.
If one or more errors are bigger than the predefined limits, the procedure has to be repeated.
All measurements of the current run are rejected and none of them is averaged with the
results from previous runs.
7.
TOOLS Adjustment Accuracy
<No.of Meas:> Shows the number of runs executed. One run consists of a measurement in
face I and face II.
<
l Comp:> and similar lines show the standard deviations of the determined adjustment
errors. The standard deviations can be calculated from the second run onwards.
It is recommended to measure at least two runs.
8.
MEAS
(F5) if more runs have to be added. Continue with step 3.
OR
CONT
(F1) to accept the measurements and to proceed to TOOLS Adjustment Results. No
more runs can be added later.
± 9°
~ 100 m
180°
180°
IF the results are
THEN
to be stored
CONT
(F1) overwrites the old adjustment errors with the new ones, if the Use
status is set to Yes.
to be determined again
REDO
(F2) rejects all new determined adjustment errors and repeats the
whole procedure. Refer to step 3. of paragraph "Combined adjustment proce-