GeoMax Zoom80 R Скачать руководство пользователя страница 4

Zoom80

 | 4

Table of Contents

6.7

Electromagnetic Compatibility EMC

37

6.8

FCC Statement, Applicable in U.S.

38

7

Technical Data

40

7.1

Instrument

40

7.1.1

General Technical Data of the Instrument

40

7.1.2

Angle Measurement

42

7.1.3

Distance Measurement with Reflectors

42

7.1.4

Distance Measurement without Reflectors

43

7.1.5

Distance Measurement - Long Range (LO mode)

43

7.1.6

Aim360

44

7.1.7

Scout360

45

7.1.8

Scale Correction

45

7.1.9

Reduction Formulas

47

7.2

Conformity to National Regulations

48

7.2.1

Instrument

48

7.2.2

ZRT81

49

8

Software Licence Agreement

50

Index

51

Содержание Zoom80 R

Страница 1: ...GeoMax Zoom80 Series User Manual Version 2 2...

Страница 2: ...t avoided could result in death or serious injury CAUTION Indicates a potentially hazardous situation or an unintended use which if not avoided may result in minor or moderate injury NOTICE Indicates...

Страница 3: ...actFlash Card 19 3 6 1 Instrument 19 3 7 Accessing Survey Application Program 20 3 8 Guidelines for Correct Results 21 4 Check Adjust 22 4 1 Overview 22 4 2 Preparation 23 4 3 Combined Adjustment l t...

Страница 4: ...ument 40 7 1 2 Angle Measurement 42 7 1 3 Distance Measurement with Reflectors 42 7 1 4 Distance Measurement without Reflectors 43 7 1 5 Distance Measurement Long Range LO mode 43 7 1 6 Aim360 44 7 1...

Страница 5: ...e measuring modes are available IR mode This mode refers to the ability to measure distances to prisms RL mode This mode refers to the ability to measure distances without prisms LO mode This mode ref...

Страница 6: ...ower Concept General Use the GeoMax batteries chargers and accessories or accessories recommended by GeoMax to ensure the correct functionality of the instrument Power options Model Description Zoom80...

Страница 7: ...sh card and GGO in two ways From the CompactFlash card directly via a serial interface to a project in GGO on a PC From the CompactFlash card using for example a card reader to a project in GGO on a P...

Страница 8: ...360 transmitter f Scout360 receiver g Coaxial optics for angle and distance measurement and exit port of visible laser beam for distance measurements h CompactFlash card compartment i Horizontal drive...

Страница 9: ...the current menu or dialog without storing changes made USER Calls the user defined menu PROG ON If the instrument is off to turn instrument on If the instrument is on press at any time to select an...

Страница 10: ...th touch screen Same functionality as the fixed key ESC The last operation will be undone CAPS The caps mode for upper case letters is active The caps mode is activated and deactivated by pressing UPP...

Страница 11: ...and overwrite are available 1 For the touch screen Highlight the characters to be changed 1 Type numeric and or alphanumeric characters 1 ENTER or tap outside of the field Step Description 1 Highlight...

Страница 12: ...g editing and deleting of items Listbox dialogs are explained in detail at appropriate places in the manuals Step Description The instrument can only be turned off in the Main Menu 1 Press and hold bo...

Страница 13: ...splayed Remote control Remote control is turned on Bluetooth The status of each Bluetooth port and any Bluetooth connection is displayed Line area The number of lines and areas currently open in the a...

Страница 14: ...ield the instrument from direct sunlight and avoid uneven temperatures around the instru ment 1 Extend the tripod legs to allow for a comfortable working posture Position the tripod over the marked gr...

Страница 15: ...simultaneously pressing and holding in the four push buttons 1 Place the ZRT81 onto the instrument by simultaneously pressing and holding in the four push buttons Ensure that the interface connection...

Страница 16: ...he instrument responds with two short beeps Whenever a device is removed the instrument responds with one long beep ZRT81 ZRT81 is automatically detected by the instrument when it is attached and the...

Страница 17: ...or a long time three months it is effectual to make only one charge discharge cycle For Li Ion batteries a single discharging and charging cycle is sufficient We recommend carrying out the process whe...

Страница 18: ...from the battery housing 4 A pictogram of the battery is displayed inside the battery housing This is a visual aid to assist in placing the battery correctly 5 Place the battery into the battery housi...

Страница 19: ...CompactFlash card compartment 3 Pull the front of the CompactFlash card up and take the card out of the lid 4 Place the lower end of the CompactFlash card at the lower end of the CompactFlash card com...

Страница 20: ...elists can be selected Output Codes have already been stored in the selected Job If codes had been copied from a System RAM codelist then the name of the codelist is displayed If codes have not been c...

Страница 21: ...nly allowed to prisms that are more than 1000 m 3300 ft away Accurate measurements to prisms should be made in IR mode When a distance measurement is triggered the EDM measures to the object which is...

Страница 22: ...on tripod Precise measurements To get precise measurements in the daily work it is important To check and adjust the instrument from time to time To take high precision measurements during the check...

Страница 23: ...n one process Before determining the instrument errors the instrument has to be levelled using the elec tronic level SHIFT F12 to access STATUS Level Laser Plummet Level page The tribrach the tripod a...

Страница 24: ...late the instrument errors If one or more errors are bigger than the predefined limits the procedure has to be repeated All measurements of the current run are rejected and none of them is averaged wi...

Страница 25: ...ruments change automatically to the other face The fine pointing has to be performed manually in both faces 5 TOOLS Tilting Axis Adjustment II MEAS F1 to measure the same target in the other face and...

Страница 26: ...tered no adjustments are necessary b If one or both circular levels are not centered adjust as follows Instrument If it extends beyond the circle use the supplied allen key to centre it with the adjus...

Страница 27: ...out on a bright smooth and horizontal surface like a sheet of paper 4 Mark the centre of the red dot on the ground 5 Turn the instrument through 360 slowly carefully observing the movement of the red...

Страница 28: ...djustment After long periods of storage inspect the field adjustment parameters given in this user manual before using the product Li Ion batteries Refer to 7 Technical Data for information about stor...

Страница 29: ...ance Motorisation An inspection of the motorisation in motorised instruments must be done in a GeoMax authorised service workshop Following conditions After about 4000 hours operation Twice a year in...

Страница 30: ...ns Modification or conversion of the product Use after misappropriation Use of products with recognisable damages or defects Use with accessories from other manufacturers without the prior explicit ap...

Страница 31: ...l installations and follow their instructions NOTICE With the remote control of products it is possible that extraneous targets will be picked out and measured Precautions When measuring in remote con...

Страница 32: ...d which may impair health If batteries are damaged or are heated strongly they can explode and cause poisoning burning corro sion or environmental contamination By disposing of the product irresponsib...

Страница 33: ...ht conditions The risk of injury for laser class 3R products is limited because of a unintentional exposure would rarely reflect worst case conditions of e g beam alignment with the pupil worst case a...

Страница 34: ...s classified as laser class 1 in accordance with IEC 60825 1 2007 03 Safety of laser products EN 60825 1 2007 10 Safety of laser products Class 1 laser products are safe under reasonably foreseeable c...

Страница 35: ...e No 50 dated June 24 2007 This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device mu...

Страница 36: ...ion is excluded from the scope of IEC 60825 1 2007 03 Safety of laser products The product described in this section is classified as exempt group in accordance with IEC 62471 2006 07 and does not pos...

Страница 37: ...to the information about electromagnetic compatibility provided by the manu facturer CAUTION Disturbances caused by electromagnetic radiation can result in erroneous measurements Although the product...

Страница 38: ...equipment Labelling Zoom80 Labelling internal battery ZBA400 This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC rules These...

Страница 39: ...s 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Type ZRT81 Art No 804597 Power 7 4V...

Страница 40: ...20 x 240 pixels colour graphics capable LCD illumination touch screen Keyboard 34 keys including 12 function keys and 12 alphanumeric keys illumi nation Angle Display 360 360 decimal 400 gon 6400 mil...

Страница 41: ...mum rotating speed 45 50 gon s External supply voltage Nominal voltage 12 8 V DC Range 11 5 V 13 5 V Type Li Ion Voltage 7 4 V Capacity ZBA400 4 4 Ah Type Operating temperature C Storage temperature C...

Страница 42: ...nt mgon mgon Zoom80 S R 1 0 3 0 1 0 1 Zoom80 S R 2 0 6 0 1 0 1 Zoom80 S R 5 1 5 0 1 0 5 Reflector Range A Range B Range C m ft m ft m ft Circular prism 1800 6000 3000 10000 3500 12000 3 prisms 2300 75...

Страница 43: ...in strong sunlight severe heat shimmer E Object in shade sky overcast F Underground night and twilight Standard measuring std dev ISO 17123 4 Measure time typical s Measure time maximum s 0 m 500 m 2...

Страница 44: ...nge Track360 mode m ft m ft Circular prism 1000 3300 800 2600 360 prism 800 2600 600 2000 360 Mini prism 350 1150 300 1000 Mini prism 500 1600 400 1300 Reflective tape 60 mm x 60 mm 55 175 not qualifi...

Страница 45: ...ed with an accuracy of 1 ppm The following parameters must be redetermined Air temperature to 1 C Air pressure to 3 mbar Relative humidity to 20 Air humidity The air humidity influences the distance m...

Страница 46: ...scale factor is not unity this formula cannot be directly applied Atmospheric correc tions C Atmospheric corrections in ppm with temperature C air pressure mb and height m at 60 relative humidity Form...

Страница 47: ...0 F 70 F 60 F 50 F 40 F 30 F 20 F 10 F 0 F 10 F 20 F 130 F 120 F 110 F 100 F 90 F 80 F 70 F 60 F 50 F 40 F 30 F 20 F 10 F 0 F 10 F 20 F 16 ft 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 inch Hg 16...

Страница 48: ...an of all meas urements Di Single slope distance measurement n Number of distance measurements Standard deviation of the arithmetic mean of the distance s Standard deviation of a single measurement n...

Страница 49: ...rovisions of Directive 1999 5 EC The declaration of conformity is available from GeoMax AG Class 1 equipment according European Directive 1999 5 EC R TTE can be placed on the market and be put into se...

Страница 50: ...conditions of the GeoMax Software Licence Agreement Such agreement is provided together with all products and can also be referred to and downloaded at the GeoMax home page at http www geomax positio...

Страница 51: ...ntents For instrument 7 Control unit 40 Conversion of data 7 Corrections Automatic 42 Scale 45 D Data conversion 7 Data Conversion 7 Data Storage 7 Data transfer to GGO 7 Definition of Use 30 Descript...

Страница 52: ...ng 41 Reduction Formulas 47 Reflectors 41 Responsibilities 31 S Safety Directions 30 Screen 10 Scroll bar description 10 Setup For remote control 15 Instrument 14 SHIFT 9 13 Software Application progr...

Страница 53: ...Index Zoom80 53...

Страница 54: ...GeoMax Zoom80 Series GeoMax AG www geomax positioning com 794008 2 2 0en Original text 2013 GeoMax AG Widnau Switzerland...

Отзывы: