4. MAINTENANCE AND TROUBLE SHOOTING 

 

4.1  Battery 

 
The GK-401 uses one 12-volt rechargeable, lead acid type battery to run the Readout.  
This battery has an extremely long shelf life and will lose approximately 2% of it’s 
charge per month sitting on the shelf.  At 60

°

F (15

°

C) the box will operate continuously 

for a minimum of 20 hours; at -20

°

F (-30

°

C) this period is cut to less than 10 hours.  At 

higher temperatures the capacity goes up however, the useful service life decreases. 
 
This battery can be expected to last 3 to 5 years, or between 250 and 500 discharge and 
recharge cycles. 
 
Recharging is accomplished by a charger which is included with each readout.  Overnight 
(10 to 12 hours) is usually long enough to bring the battery to full charge.  The charger 
can be left plugged in whenever the Readout is not is use (recommended) to ensure full 
charge on the battery at all times.  As the battery ages, the on-time will be reduced, and at 
some point, will be very short and recharging will not help.  At this point the battery will 
need to be replaced.  Battery packs are available from Geokon, or a battery can be 
purchased locally (see Appendix A for battery specifications) and installed by the user 
(see Appendix D for battery replacement instructions). 
 
In cases where the battery will no longer operate in the field Geokon should be contacted 
for remedial measures. 
 

4.2  Readout System 

 
If the readout system fails to operate properly, and the cause is not the battery, Geokon 
should be contacted.  The unit should not be opened in the field.  A few checks can be 
made, however: 
 

 If zeros appear in the display with gages connected, patch cords should be checked 

for continuity between contacts and clip leads (see Appendix B). 

 The gage itself should be checked; see gage manual. 

 The processor may need to be reset, which can be accomplished by turning the unit 

off and on. 

 The selector position may be incorrect (see Table 1). 

 Noise levels may be excessive; try reading a gage in a different area; try connecting 

the ground lead (white or green clip) to the shield drain wire. 

 

4.3 Calibration 

 

The readout should be sent periodically (every 12 months) back to the manufacturer for 
inspection, cleaning, and calibration.  A nominal fee will be charged for the service, but it 
is highly recommended. 

Содержание GK-401

Страница 1: ... contained herein is believed to be accurate and reliable However Geokon Inc assumes no responsibility for errors omissions or misinterpretation The information herein is subject to change without notification Copyright 1987 1995 2000 2003 by Geokon Inc Doc Rev D 11 03 Instruction Manual Model GK 401 Vibrating Wire Readout ...

Страница 2: ......

Страница 3: ...re are no warranties except as stated herein There are no other warranties expressed or implied including but not limited to the implied warranties of merchantability and of fitness for a particular purpose Geokon Inc is not responsible for any damages or losses caused to other equipment whether direct indirect incidental special or consequential which the purchaser may experience as a result of t...

Страница 4: ......

Страница 5: ...ION 4 APPENDIX A GK 401 SPECIFICATIONS 5 APPENDIX B CONNECTOR PINOUTS 6 APPENDIX C BATTERY PACK REPLACEMENT INSTRUCTIONS 7 APPENDIX D THERMISTOR LINEARIZATION 8 APPENDIX E READING OTHER MANUFACTURERS SENSORS 9 TABLES TABLE 1 GK 401 DISPLAY POSITION VS GEOKON MODEL NUMBER 2 TABLE 2 THERMISTOR RESISTANCE VS TEMPERATURE 8 TABLE 3 VIBRATING WIRE LENGTH VS FREQUENCY RANGE 9 ...

Страница 6: ......

Страница 7: ...se of varying frequency is generated by the Readout Box and is applied to an electromagnetic coil assembly which is located close to the sensing wire When a frequency corresponding to that of the wire is generated the wire is plucked and vibrates at that frequency The wire continues to vibrate after the pluck ends and a signal primarily the resonant frequency is induced in the coil assembly and tr...

Страница 8: ...62 D 4200 µstrain 450 1200 Hz 3 304 E 4100 µstrain 1500 3500 Hz 0 391 F 4300EX f2 10 3 digits 2500 6000 Hz 1 000 Notes General position for all gages possibility of harmonics in 4000 and 4200 gages at very low strain levels The period readings can be very useful for greater resolution of strain measurements Also measurements as low as 0 1 µstrain can be made see individual manuals Factor multiplie...

Страница 9: ...be limited to temperature barometric pressure weather conditions water levels fill levels nearby construction activity etc Initial readings properly obtained are the baseline for all further measurements 2 Always obtain stable readings if a reading fluctuates be sure to note it 3 Compare current readings with previous readings while at the site numbers sometimes get transposed in notebooks 4 Use p...

Страница 10: ...e replaced Battery packs are available from Geokon or a battery can be purchased locally see Appendix A for battery specifications and installed by the user see Appendix D for battery replacement instructions In cases where the battery will no longer operate in the field Geokon should be contacted for remedial measures 4 2 Readout System If the readout system fails to operate properly and the caus...

Страница 11: ...r 80C85 CPU operating 3 072 MHz 256 Bytes SRAM 2048 Bytes EPROM Oscillator Frequency 6 144 MHz Display 5 digit LCD 7 high Battery 1 12 volt Panasonic lead acid LC SD122EU Battery Capacity 2 0 Amp Hour Operating Current 110 mA Operating Time minimum 20 hours 60 F Quiescent Current 20 µA Input Connector Gage Lemo FGG 1K 303 CNAC470 Input Connector Charger Lemo FGG 0K 303 CNAC37 Dimensions 6 4 8 165 ...

Страница 12: ...ad Old Style Gage Connector 6 pin Lemo ERA 1E 306 CNL Pin Description To 1 Ground Green Clip Lead 2 No Connection NA 3 Gage Positive Red Clip Lead 4 No Connection NA 5 Gage Negative Black Clip Lead 6 No Connection NA Charger Connector Pin Description To 1 Charger Negative Charger Black Lead 2 No Connection NA 3 Charger Positive Charger Striped Lead ...

Страница 13: ...k from the box it is a tight fit 5 If a new pack has been supplied connect the leads to the readout assembly and reverse the above steps If just the battery has been purchased the old battery must be removed from the pack and the new one wired in the same manner and glued into the pack before putting the pack into the case RTV holds it in place very nicely NOTE The only screws that should be remov...

Страница 14: ...8 120 94 48K 39 9310 1 1535 41 364 9 81 113 8 121 88 46K 38 8851 2 1475 42 353 4 82 110 8 122 82 87K 37 8417 3 1418 43 342 2 83 107 9 123 77 66K 36 8006 4 1363 44 331 5 84 105 2 124 72 81K 35 7618 5 1310 45 321 2 85 102 5 125 68 30K 34 7252 6 1260 46 311 3 86 99 9 126 64 09K 33 6905 7 1212 47 301 7 87 97 3 127 60 17K 32 6576 8 1167 48 292 4 88 94 9 128 56 51K 31 6265 9 1123 49 283 5 89 92 5 129 53...

Страница 15: ...ad them Gage factors need to be known in order to convert readings to engineering units The readings can be taken in the period mode Position A and conversions to strain pressure etc can be made using the manufacturers factors supplied with the gages The table below lists approximate operating frequency ranges for different wire lengths for reference Wire Length Frequency Range 1 2500 5000 Hz 2 12...

Отзывы: