7
APPENDIX A. SPECIFICATIONS
A.1 CR800 Measurement and Control Module
Power requirements: 9.6 to 16 VDC
Analog measurement current drain: 27.6 mA
Processing current drain: 16.2 mA
Quiescent current drain: .6 mA
Operating temperature: -25
to +50
C
Processor: Hitachi H8S 2322
Memory: 2Mb ROM, 4Mb RAM
Storage capacity: 2,000,000 Final Storage Locations
Real time clock accuracy:
3 minutes per year
Expansion capability: up to 2 x 32 channel multiplexers (single ended)
System battery: 12 V, 7 Ahr lead acid
Communication: RS-232 115200 baud, eight data bits, no parity, one stop bits
A.1.1 Analog Inputs
Configuration: Three differential or six single-ended
Voltage measurement accuracy: 0.06% of FSR for 0
to 40
C
Voltage measurement ranges and resolution:
Range
Resolution
5.0 V
1330
V
2.5 V
667
V
250 mV
66.7
V
25 mV
6.7
V
7.5 mV
2
V
2.5 mV
.67
V
Common mode range:
5 VDC
DC common mode rejection (CMRR): >100 dB
Maximum input voltage: 16 VDC
A.1.2 Excitation Outputs
Configuration: Two switched output channels
Excitation range:
2.5 V
Excitation resolution: 0.67 mV
Excitation accuracy: 0.06% of FSR for 0
C to 40
C
Output current: 25 mA @ 2.5 VDC
A.1.3 Pulse Inputs
Configuration: two 24 bit
Maximum count rate: 16.7x10^6
Maximum input voltage: ±20 VDC
Modes: Switch closure, high frequency pulse, low level AC