18
10)
Check continuity from each end of a signal wire, or to a transducer, and ensure there are no
shorts to each other, or to the stainless steel cable housing.
11)
Slide the 13 mm (0.5") diameter tube section of the splice so that it is centered on the solder
joint.
12)
Using the two 12 mm (0.5") wrenches, tighten the 4 mm (0.16") Swagelok onto this piece
until it is approximately 270 degrees past finger tight. (See Appendix C for Swagelok
instructions.)
13)
Slide the other piece of the splice (the one that has the 13 mm (1/2") Swagelok), until it
comes to a positive stop on the 13 mm (1/2") tube.
14)
Using the 5 mm and 23 mm (13/16" and 7/8") wrenches, tighten the 13 mm (1/2") Swagelok
450 degrees past finger tight.
15)
Using the two 12 mm (0.5") wrenches, tighten the remaining 4 mm (0.16") Swagelok until it
is approximately 270 degrees past finger tight.
16)
Perform a continuity and short check to verify a successful splice was made.