Programmable Presets

Normal Default Mode

Presets Mode

Edit Preset Temp

Edit Preset Pressure/Height

Programmable presets are stored

programs where commonly used
Temperature, Time and Height
(pressure) settings can be stored and
retrieved.

Presets can be recalled simply by

pressing the PRG key, selecting the
program desired with the arrow keys,
and pressing the PRG key again. This
will update the current settings on the
press with the settings in the preset.

Presets can be edited by pressing the

TEMP key while inside the programs.
When the display shows “SEt”, press the
TEMP key to change the temperature,
time and PRS (height) settings for that
preset. The TEMP key moves the
flashing value from Temp to Time to
PRS and back to “SEt”. The arrow keys
change the value.

So... the PRG key enters into the

presets, and also exits the presets. When
exiting the presets, the press’
temperature & time is updated with the
values that were stored in the preset, and
the PRS display tells the operator what
height level to adjust the pressure to.

Press   PRG

○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

Edit Preset Time

Press   TEMP

Press   PRG

Press   TEMP

Press   TEMP

Press   TEMP

Содержание Digital Knight K20S

Страница 1: ...1 Digital Knight Digital Knight Digital Knight Digital Knight Digital Knight 16x20 Digital Swinger 16x20 Digital Swinger 16x20 Digital Swinger 16x20 Digital Swinger 16x20 Digital Swinger...

Страница 2: ...rogrammable Presets 8 User Options Menu 9 Fahrenheit Celsius 9 Timer Counter 9 Recorded Pressings 9 Pressure Height Gauge Calibration 10 Height Gauge High Point 10 Height Gauge Low Point 10 Pressure H...

Страница 3: ...effort in using this press and in your heat pressing applications Throughout this manual many areas and components of this machine will be referred to by specific names Please refer to the illustratio...

Страница 4: ...n use Basic Use Setting Time The time setting is always editable in the default operating mode of the controller The left two digits of the time display are minutes The right two digits are seconds Th...

Страница 5: ...ange of the controller is from 150 F to 550 F 65 C to 288 C During the first heat up cycle of the press the controller will display 150 F 65 C until the heat platen temperature rises above that temper...

Страница 6: ...e display will change to the pressure gauge display The units of measure are a relative scale from 0 00 to 10 00 with 02 increments The top will always display PRS To view the current pressure display...

Страница 7: ...reduce the life of the silicone pad When pressing rigid substrates plastics metals woods etc be sure that any protective films or laminates are removed before heating Always check that the transfer i...

Страница 8: ...preset Presets can be edited by pressing the TEMP key while inside the programs When the display shows SEt press the TEMP key to change the temperature time and PRS height settings for that preset The...

Страница 9: ...renheit Celsius The Current Set Point and Preset temperature values can be displayed in Fahrenheit or Celsius To change the value to F or C use the arrow keys Press PRG to move to the next menu item T...

Страница 10: ...The digital pressure height gauge is calibrated from the factory to recognize the lowest and highest pressure points settable on the press By defining the highest and lowest points of adjustment the c...

Страница 11: ...he pressure Conversely sometimes the operator may adjust the pressure knob but the PRS value does not display unless the knob is turned very quickly By lowering the value the display will activate bas...

Страница 12: ...erent alarms available to choose from These alarms are sounded at the end of the timing cycle as well as if the Drop Sense feature is enabled Use the arrow keys to change the values or to turn the ala...

Страница 13: ...ure proper operation The clamp linkage assembly is the greatest area of wear and friction on the press The posts that connect to the heat platen should be lubricated with SuperLube a clear high temper...

Страница 14: ...head for the machine is lowered the lever of the timer switch should move down and the contact button click out The timer switch may need to be loosened and moved along the bracket to a position that...

Страница 15: ...can be obtained in any auto parts or hardware store Lower the heater but do not clamp the press Thoroughly clean the posts that come out of the heat platen as well as the pins the holes the pins pass...

Страница 16: ...to recall the defective press to the factory for repairs if on site component replacement is deemed not possible by Geo Knight Co A return authorization must be granted by Geo Knight Co prior to its r...

Отзывы: