background image

11

40

V

id

e

W

ir

e

CM-02NLRV or
CM-02NLRV-C

Electrical Lock

2

MONITOR

CALL

UNLOCK

BUSY
POWER

TALK

UNI-TALK

CALL

MONITOR

UNLOCK

MIC

BUSY

TALK

CM-02NLRI

CM-02NLRG or
CM-02NLRG-C

MONITOR

CALL

UNLOCK

BUSY

POWER

CM-02NLRM or
CM-02NLRM-C

2

4

4

2

Video Wire

6

6

6

6

PS-5E Power

2

PS-5E Power

Indication

CM-03NLCH-162

Setup

A+18V AFOUT DATA AGND MONI V+18V VGND TVOUT

T&R

MONI AGND V+18V VGND TV

A+18V GND

T&R

MONI AGNDV+18V VGND TV

A+18V

A+18V AFIN

DATA AGND MONI V+18V VGND TVIN

T&R

MONI AGNDV+18V VGND TV

A+18V GND

T&R

MONI AGNDV+18V VGND TV

A+18V

Indication

CM-03NLCH-162

Setup

A+18V AFOUT DATA AGND MONI V+18V VGND TVOUT

T&R

MONI AGND V+18V VGND TV

A+18V GND

T&R

MONI AGNDV+18V VGND TV

A+18V

A+18V AFIN

DATA AGND MONI V+18V VGND TVIN

T&R

MONI AGNDV+18V VGND TV

A+18V GND

T&R

MONI AGNDV+18V VGND TV

A+18V

6

¡

System diagram 

1.

£

Non-Network system diagram

(1)Non-Network video system diagram

£

Door Station

+DC-

¡

AC

¡

TRANSFORMER

Model

£

PS-5E

Input

£

230V

¡

50Hz

Output

£

18V     800mA

Notes:Used in indoor

+DC-

¡

AC

¡

TRANSFORMER

Model

£

PS-5E

Input

£

230V

¡

50Hz

Output

£

18V     800mA

Notes:Used in indoor

9

¡

Wiring Material

Mo-
del

Wire material requirements(vertical square)

Remarks

V

id

e

o s

y

st

e

m

Diagram

Between door 
station and 
module

Between door
station and power 
supply

¡

30M

RVV6

¡

0.75mm 

2

¡

100M

RVV2

¡

1.0mm

2

¡

10M

RVVP6

¡

0.75mm 

       

RVVP5

¡

1.0mm 

              

2

2

Between 
module
and 
indoor 
phone

RVV4

¡

0.5mm  +SYV75-5/96

2

¡

30M

¡

100M

Hand-set

indoor 

phone

Hand-free

indoor

phone

RVV6

¡

0.75mm +SYV75-5/96

2

RVV4

¡

1.5mm  +SYV75-5/96

2

RVV6

¡

1.5mm +SYV75-5/96

2

¡

10M

¡

100M

¡

800M

¡

200M

Between 
Conformity unit 
and management 
unit

Between door 
station and module

¡

30M

RVV4

¡

0.5mm 

2

¡

100M

RVV4

¡

1.0mm 

2

¡

30M

¡

100M

¡

100M

¡

200M

RVV2

¡

0.3mm 

RVVP4

¡

0.75mm 

2

2

RVV2

¡

1.0mm 

2

Among switch ,
door station and 
module

Between Network
switch and 
Conformity unit s
BUS board

'

When 4 rout ways

three wires are data wire and eight wires are audio 

wire in the 11-core wire
When 3 rout ways

three wires are data wire and six wires are audio 

wire in the 9-core wire
When 2 rout ways

three wires are data wire and four wires are audio 

wire in the 7-core wire
When 1 rout ways

three wires are data wire and two wires are audio 

wire in the 5-core wire

£RVVP11¡1.0mm

SYV75-7/128

(

£RVVP9¡1.0mm

 +

3 video wires

 

SYV75-7/128

)

(

£RVVP7¡1.0mm

 +

2 video wires

 

SYV75-7/128(

(

£RVVP5¡1.0mm

 +

1 video wires

 

SYV75-7/128

)

(

 +

4 video wires

 

)

Between Network 
switch and 
Conformity unit s 
BUS board

'

When 4 rout ways RVVP11¡1.0mm shield wire three wires are 
    data wire and eight wires are audio wire in the 11-core wire
When 3 rout ways RVVP9¡1.0mm shield wire  three wires are 
    data wire and six wires are audio wire in the 9-core wire  
When 2 rout ways RVVP7¡1.0mm shield wire  three wires are 
    data wire and four wires are audio wire in the 7-core wire  
When 1 rout ways RVVP5¡1.0mm shield wire  three wires are 
    data wire and two wires are audio wire in the 5-core wire  

£

(

)

£

 

)

(

 

£

 

)

(

£

 

)

(

             

¡

800M

RVVP5

¡

1.0mm 

2

RVVP4

¡

1.0mm 

2

SYV75-5/96 PCS

¡

       

RVVP6

¡

1.0mm 

       

2

SYV75-5/96 PCS

¡

       

SYV75-7/128 PCS

¡

       

SYV75-5/96 PCS

¡

RVV6

¡

1.5mm 

2

SYV75-5/96 PCS

¡

Note:(1)in this charts, R

VVP

 represent the shield-wire

         (2)Actual wire depended on capacity of the project! 

When exceed the ordered distance, please enlar

ge the square accordingly

         (3)when network, if the total distance is exceed 200M, please add one video amplifier and repeaters.

         (4)the parameter in this chart is only for reference, our company reserve the right to change and explain.

Between door
station and 
electrical lock

RVV2

¡

1.0mm

2

Between 
conformity and 
management unit

A

u

d

io s

y

st

e

m

Among switch ,
door station and 
module

RVV4

¡

0.3mm 

2

RVV4

¡

1.0mm 

2

Between
module
and 
indoor 
phone

Hand-set

indoor 

phone

Hand-free

indoor phone

12V
 Power

Содержание CM-03NL

Страница 1: ...WL CM 03NL E crust Network video doorphone system Edition V1 00 Please don t abandon the products as wastes at will It should be recycled and disposed separately Thanks...

Страница 2: ...r VM 01R video receiver 1 VM 01T video sender 12V GND terminal connect respectively with DC12V power s positive negative polarity VIDEO GND connect with camera VIDEO VIDEO connect with VM 01R s VIDEO...

Страница 3: ...equipment attachments Attached supplemental manual for network video door phone s relay equipments Relay equipment features VM 03N video amplifier amplifies the video signal for long distances VM 01T...

Страница 4: ...her it is right or wrong All users of whole building can not unlock Check whether the wire from door station to power and power to electrical lock is correct or not whether the electrical lock is comp...

Страница 5: ...e screws with the attached inner hexagon wrench and then take off the door station back cover Fix the back cover on the iron door Then lock the door station from the back cover with the attached two M...

Страница 6: ...et for calling management unit otherwise for emergency call 2 For main indoor phone internal call broadcase among extra indoor phones in the same apartment 3 Management Power Indicator Busy Indicator...

Страница 7: ...er 5 Voice volume Slide cover 13 14 1 7 9 8 14 5 6 12 13 10 11 2 3 4 201 0 67 8 mm WL 02NLFD 4 Audio indoor phone 144 5mm Installation diagram 216 94 59 mm WL 02NLFH Size Model 3 Installation size and...

Страница 8: ...18V VGND TVIN T R MONI AGNDV 18V VGND TV A 18V GND T R MONI AGNDV 18V VGND TV A 18V Setup CM 03NLCH Indication DC AC TRANSFORMER Model PS 5E Input 230V 50Hz Output 18V 800mA Notes Used in indoor 12 I...

Страница 9: ...the door station and unlock the door 3 Broadcasting between the indoor phones Pick up the handset the indoor phone s Talk indicator will light press the Call button for seconds and release then broad...

Страница 10: ...ing press and input the room No that s all For example If you want to call NO 102 family when room number is three digits press Room No 102 When room number is four digits press Room No 0102 If the Ro...

Страница 11: ...wrong password more than 5 times at one time then the door station will give an alarm to the management unit automatically Change unlock password Press 3 F3 the door station displays Addr enter the r...

Страница 12: ...unlock password the door station will display Pd p If you input wrong unlock password more than five times at the same time the door station will shut down automatically Note when the system operate...

Страница 13: ...T button on the module if the indicate light is flickering slower then you can quit the setting Put the pin cap to the COM position to avoid the losing of the room number Please note one module can se...

Страница 14: ...oor station and module Between Network switch and Conformity unit s BUS board When 4 rout ways three wires are data wire and eight wires are audio wire in the 11 core wire When 3 rout ways three wires...

Страница 15: ...unit s PORT board and management unit LA Data A LB Data B COM Common terminal AF AF OR BK BL GR YL Audio Audio GND Wiring among switches Network Switch Audio GND input for No 1 route way Audio input f...

Страница 16: ...ER Model PS 5E Input 230V 50Hz Output 18V 800mA Notes Used in indoor PS 5E PS 5E DC AC TRANSFORMER Model PS 5E Input 230V 50Hz Output 18V 800mA Notes Used in indoor DC AC TRANSFORMER Model PS 5E Input...

Страница 17: ...NLRJ Wiring instruction from module to i Video system Wiring from module to audio indoor phone 4 Wiring between switches and among switch door station and conformity unit Wiring between switch and doo...

Страница 18: ...o module POWER Audio power AF DATA GND MONI Monitor 18V TV TV A 18V AFIN DATA AGND MONI V 18V VGND TVIN 3 Wiring instruction from module to indoor phone Audio Monitor Audio cortrol GND Video T R MONI...

Страница 19: ...GND T R MONI AGNDV 18V VGND TV A 18V A 18V AFIN DATA AGND MONI V 18V VGND TVIN T R MONI AGNDV 18V VGND TV A 18V GND T R MONI AGNDV 18V VGND TV A 18V TVIN VGND V 18V MONI AGND DATA AFIN A 18V MONI AGN...

Страница 20: ...l button Only for CM 02NLRM1 DC AC TRANSFORMER Model PS 5E Input 230V 50Hz Output 18V 800mA Notes Used in indoor DC AC TRANSFORMER Model PS 5E Input 230V 50Hz Output 18V 800mA Notes Used in indoor AI1...

Страница 21: ...Wiring among switch module and door station Wires between network switches the audio output AO of the first network switch are connected with the corresponding audio input AI of the next network swit...

Страница 22: ...l phone AF1 AF1 AF2 AF2 LA LB COM AF1 AF1 AF2 AF2 AF3 AF3 AF4 AF4 in the BUS board of conformity unit are connected to AI1 AI1 AI2 AI2 AI3 AI3 AI4 AI4 in the network switch correspondingly TV1 TV1 TV2...

Страница 23: ...3 AF3 and AF4 AF4 in the bus board of the conformity unit should be connected with AI1 AI1 AI2 AI2 AI3 AI3 and AI4 AI4 of the network switch accordingly Video line TV1 TV1 TV2 TV2 TV3 TV3 and TV4 TV4...

Страница 24: ...ch should be correspondingly connected PS 9 Power AI1 VI1 AI2 VI2 AI3 VI3 AI4 VI4 COM LB LA AO1 VO1 AO2 VO2 AO3 VO3 AO4 VO4 POWER GND AF DATA TV TV MONI 18V 18V GND AF DATA TV TV MONI POWER MONI TV TV...

Страница 25: ...ER GND AF DATA TV TV MONI 18V GND AF DATA TV TV 18V GND 18V TV TV Electrical Lock Input terminal from conformity unit CM 03NQH2 162 Network Switch Conncet with next network switch a 03NQH2 162 03NLCH...

Страница 26: ...2 CN3 CN4 POWER GND AF DATA TV TV MONI 18V 18V MONI TV TV DATA AF GND POWER PS 5E Power GND AF DATA TV TV 18V PS 5E Power Input terminal from conformity unit Extra Door Station Door Station CM 03NLCH...

Страница 27: ...ly c Wiring among CM 03NQH switch CM 03NLCH 162 module and door station Note The genenal wiring should be done with loose wires If you can not use a cable but only loose wires then you need a repeater...

Страница 28: ...ct with next network switch AFOUT A 18VAFIN DATA AGND MONIV 18VVGND TVIN TVOUT AFOUT A 18V AFIN DATA AGND MONI V 18V VGND TVIN TVOUT 1 T R 2 MONI 3 AGND 4 18V 5 VGND 6 TV CN1 CN2 CN3 CN4 CM 03NLCH Mod...

Отзывы: