27
24
+
PS-5E
Door Station
Electrical
Lock
+AI1- +VI1- +AI2- +VI2- +AI3- +VI3- +AI4- +VI4-
COMLB LA
+AO1-+VO1- +AO2-+VO2- +AO3-+VO3- +AO4-+VO4-
POWERGND
AF
DATA TV+
TV-
MONI +18V
+18V
GND
AF
DATA
TV+
TV-
MONI
POWER
MONI
TV
-
TV+
+18V
DA
T
A
AF
GND
COM
LB
LA
AI1+
AI1-
VI1+
VI1-
AI2+
AI2-
VI2+
VI2-
AI3+
AI3-
VI3+
VI3-
AI4+
AI4-
VI4+
+AI1- +VI1- +AI2- +VI2- +AI3- +VI3- +AI4- +VI4-
COMLB LA
+AO1-+VO1- +AO2-+VO2- +AO3-+VO3- +AO4-+VO4-
POWERGND
AF
DATA TV+
TV-
MONI +18V
+18V
GND
AF
DATA
TV+
TV-
MONI
POWER
MONI
TV
-
TV+
+18V
DA
T
A
AF
GND
COM
LB
LA
VI4-
POWER
GND
AF
DA
T
A
TV+
TV
-
MONI
+18V
+18V
MONI
TV
-
TV+
DA
T
A
AF
GND
POWER
GND
AF
DATA
TV+
TV-
+18V
PS-5E
Power
Input terminal from conformity unit
Extra Door Station
CM-03NQH Network Switch
CM-03NQH Network Switch
CM-03NLCH-162 Module
Indication
CM-03NLCH-162
Setup
A+18V AFOUT DATA AGND MONI V+18V VGND TVOUT
T&R
MONI AGND V+18V VGND TV
A+18V GND
MONI AGNDV+18V VGND TV
A+18V
A+18V AFIN
DATA AGND MONI V+18V VGND TVIN
T&R
MONI AGNDV+18V VGND TV
A+18V GND
T&R
MONI AGNDV+18V VGND TV
A+18V
T&R
A+18V
AFIN
DA
T
A
AGND MONI
V+18V
VGND
TVIN
Electrical
Lock
Wires between network switches :the audio output(AO) and
video output(VO) of the first network switch are connected
with the corresponding audio input(AI) and video input(VI)
of the next network switch. The data wire COM¡LA¡LB should be connected accordingly.
c)Wiring among
CM-03NQH switch,CM-03NLCH-162 module and door station
£
Note
£
The genenal wiring should be done with loose wires . If you can not use a cable but only
loose wires, then you need a repeater. If the distance is less than 100 meters,(if it is more than 100
meters you will need a repeater)one network switch can connect with 100 modules, and one module
can connect with 4 indoor phones.
+DC-
¡
AC
¡
TRANSFORMER
Model
£
PS-5E
Input
£
230V
¡
50Hz
Output
£
18V 800mA
Notes:Used in indoor
-
GND
LK-
POWER
POWER
LK+
AF
DA
T
A
GND
MONI
+18V
TV
-
TV+
GND
LK-
POWER
POWER
LK+
AF
DA
T
A
GND
MONI
+18V
TV
-
TV+
POWER
AF
DATA
GND
MONI
+18V
TV-
TV+
POWER
GND
POWER
GND
AF
DATA
GND
+18V
TV-
TV+
T&R
MONI
AGND
V+18V
VGND
TV
Indication
CM-03NLCH-162
Setup
A+18V AFOUT DATA AGND MONI V+18V VGND TVOUT
T&R
MONI AGND V+18V VGND TV
A+18V GND
T&R
MONI AGNDV+18V VGND TV
A+18V
A+18V AFIN
DATA AGND MONI V+18V VGND TVIN
T&R
MONI AGNDV+18V VGND TV
A+18V GND
T&R
MONI AGNDV+18V VGND TV
A+18V
TV
VGND
V+18V
AGND
MONI
T&R
MONI
AGND
V+18V
VGND
TV
T&R
MONI
AGND
V+18V VGND
T&R
MONI
AGND
V+18V
VGND
TV
CM-02NLRJ Indoor Phone
1
A+18V
2
T&R
3
MONI
4
GND
5
6
VGND
V+18V
7
AGND
8
TV
A+18V
GND
1
A+18V
2
T&R
3
MONI
4
GND
5
V+18V
6
VGND
7
AGND
8 TV
T&R
MONI
GND
TV
AGND
VGND
A+18V
V+18V
A+18V
GND
A+18V
GND
CM-02NLRI Indoor Phone
CM-02NLRM or
CM-02NLRM-C
TV
T&R
CM-03NLCH-162
Module
102
104
103
b)Wiring between
CM-03NLCH-162 module and indoor phone
£
Connect to
door bell button
Only for
CM-02NLRM1
12V
Power
12V