11
Parameter
Unit
190L
260L
Electrical data
Power supply
V/Hz
230/50
Fuse
A
13 (10)
Electric connections
-
L1, N, G
Electric heater power
W
1500
Cooling and water circuit
Refrigerant type
-
R134a
Refrigerant quantity
g
1200
1280
GWP
-
1430
CO2 equivalent
ton
1,7
1,8
Cooling circuit
-
Hermetically sealed
Protection rating
-
IP21
Water connections - Enameled
in
¾
- BSPT (ISO 7-1)
Water connections – Stainless*
mm
22 – Compression fittings
Water condensate connection
mm
Ø19
Nominal insulation thickness
mm
50
50
Corrosion protection
-
Magnesium anode / Stainless steel
Performance data
Outdoor air at 7°C (EN16147)
COP
-
3.57
3.69
Heat up time
hh:mm
06:28
09:12
Stand-by heat losses
W
17
20
Sound
power
dB(A)
49
49
Indoor air at 20°C (EN16147)
COP
-
4,13*
4.20
Heat up time
hh:mm
05:15*
07:09
Stand-by heat losses
W
17*
21
Sound
power
dB(A)
55.6
55.6
Volume at 40°C
L
247
347
Auxiliary power
W
1.61
1.61