19
9
MOD. CS 240/5+5
9
MOD. CS 240/03
2
3
4
1
9
MOD. CS240/24 - CS240/50
EN
Rev. 00 - 12/2013 - Cod. CM31710 - Instruction manual
Compressor Mod. CS240
STANDARD MAINTENANCE TABLE
FREQUENCY
INTERVENTION AREA
INTERVENTION TYPE
ONCE A DAY
Safety devices.
Ensure they are intact, correctly installed and functioning.
Electrical cable and plug.
Visual check of usage status.
Tank.
Upon termination of each work cycle, rest the appliance on
the ground and drain the tank condensate pump opening the
condensate pump
(9)
.
EVERY WEEK
Wheels.
Wheel pressure check. Subsequently pump up with compressed
air up to a maximum of 2.5 bar.
N. 2 air filters.
Unscrew the screws
(1)
.
Remove the cover
(2)
.
Remove the seal
(3)
.
Extract the filters
(4)
and clean them using compressed air.
After re-insertion of the filters, correctly replace the cover.
notE: REPlaCE tHE FiltERS in tHE inStanCE WHERE it
iS WoRn.
Содержание C 330/50