Maintenance 

SPARE PARTS

 Code

Description

TFT9010

Cartridge to fit TFT1010

TFT9069

Adjustable Cartridge

TFT9300

Knee Operated Wand 

TFT9304

Knee Operated Cartridge

TFT9050

Flow Cup 4 - 6

TFT9052

Flow Cup 8 - 12

TFT9053

Flow Cup 12 - 16

TFT9054

Flow Cup 40 sec

O Ring Kit service 

For the following steps, a qualified plumber 
must be in charge of the maintenance and 
handling of the tapware in order to keep 
product Warranty.  The damage on parts after 
dismantling a product would not be covered 
by the warranty.

First start by 

shutting off the main water 

supply.

1.

Remove the head valve using a shifter
on the flats and remove the cartridge.

2.

Undo the stopper

3.

Set aside the crown ring

4.

Set aside the head valve from the stem

5.

Remove the washer Gaco from the head
valve and replace with the new washer
gaco.

6.

Remove the Gaco from the stopper and

replace it with the new washer Gaco

7.

Remove the “O” Ring and replace it with
the new “O” Ring

8.

Remove the “o” Ring and replace it with
the new “O” Ring

9.

Using the existing crown ring place it
back into the head valve

10. Place the stem through the head valve
11.

Apply a drop of Loxeal to the thread of
the stem

12. Replace the stopper, ensure the “O” Ring

is in place, then tighten the stopper. Do
not overtighten.

13. Fit the handle and cartridge back into

the body and tighten.

Do not overtighten.

Important note

Over thightening

 might cause the 

crown ring to move, this could cause 
malfunction of the cartridge.

Gaco

Содержание TFT1010

Страница 1: ...ve TFT3500 Foot Operated Valve TFT3600 TFT3700 Straight Shower Valve TFT1010 Adjustable Shower Valve TFT1010ADJ Shower Control Valve TFT1015KIT Shower Mixer Control Valve TFT1016KIT INSTALLATION MANUA...

Страница 2: ...chnical Drawings 6 Unit Components 8 Wall Mounted Showers Installation 10 Outlet Installation 12 Knee Valve Installation 13 Pedal Valve Installation 14 Single Temp Straight Valve 15 Time Adjustment In...

Страница 3: ...me complies with food preparation regulations Installation and servicing For durability please ensure to install all parts including strainers flow regulators Usage features Hands Free products availa...

Страница 4: ...uct Range TFT3600 TFT3600 KIT FLOOR WALL MOUNTED FOOT OPERATED VALVE KIT WITH SPOUT AVAILABLE TFT1010 TFT1010ADJ SINGLE TEMPERATURE STRAIGHT VALVE SINGLE TEMPERATURE STRAIGHT VALVE WITH ADJUSTABLE CAR...

Страница 5: ...alia com au TFT3500 TFT3500KIT KNEE OPERATED VALVE KIT WITH SPOUT AVAILABLE TTFT1016KIT TFT1015 KIT SHOWER MIXER VALVE WITH IN WALL STAINLESS STEEL BOX SINGLE TEMPERATURE SHOWER VALVE WITH IN WALL STA...

Страница 6: ...J SINGLE TEMPERATURE STRAIGHT SHOWER VALVE SINGLE TEMPERATURE STRAIGHT SHOWER VALVE WITH ADJUSTABLE CARTRIDGE GENTECH AUSTRALIA PTY LTD 68 61 45 5 6 5 G1 2 30 5 37 5 64 5 325 G1 2 33 37 5 G1 2 95 37 5...

Страница 7: ...ERATURE SHOWER VALVE WITH IN WALL STAINLESS STEEL BOX SHOWER MIXER VALVE WITH IN WALL STAINLESS STEEL BOX GENTECH AUSTRALIA PTY LTD 54 42 30 36 35 50 5 G 1 2 17 15 41 53 5 236 182 5 G 1 2 GENTECH AUST...

Страница 8: ...8 KNEE OPERATED VALVE TFT1015KIT Unit components Pressure exceding 450 kPa will void warranty...

Страница 9: ...nt Note For the Maintenance Instructions see Pag 17 OPERATION REQUIREMENTS Pressure Temperature Value Min Continuous Flow Working Pressure 150kPa Max Continuous Flow Working Pressure 450kPa Optimum Fl...

Страница 10: ...x into the wall firmly 2 Screw the main valve into the box and locate the outlet in the vertical position Product performs best at 350kPa Note Ensure the button on the valve body is aligned with the w...

Страница 11: ...FT1016KIT only screw in levers for hot and cold controls and use Lockseal to secure Connect hot left and cold right water on each side of the mixer Compliance The mixer handle is a blender valve only...

Страница 12: ...led to the requirements of AS NZS 3500 by a qualified plumber Your mixer comes to you already factory assembled and tested We do not recommend the dismantling of any internal part of the mixer The mix...

Страница 13: ...ace using the necessary screws to mount firmly onto the wall Ensure the arrow on the knee valve body figure 2 is facing up when connected to the water inlet and outlet 6 Place the filter in the water...

Страница 14: ...r or wall to prevent any movement while operating the valve 4 Use the 4 mounting screws to screw the pedal valve into place How to adjust timing For time delay adjustment see page 17 Important note We...

Страница 15: ...is facing the dicrection of the outlet 6 Connect the water inlet and outlet 7 Push into the button the colour indicator for hot or cold water Note The difference between the TFT1010 and the TFT 1010A...

Страница 16: ...xed timing options These options are available upon request and are factory installed Refer to the chart below Changing the flow cup yourself may void the product warranty ADJUSTABLE CARTRIDGE 0 TO 40...

Страница 17: ...nd remove the cartridge 2 Undo the stopper 3 Set aside the crown ring 4 Set aside the head valve from the stem 5 Remove the washer Gaco from the head valve and replace with the new washer gaco 6 Remov...

Страница 18: ...a reasonable time 2 2 8 completed credit card authorisation in the form set out in Schedule 2 to these conditions accepting liability in accordance with clause 2 6 if the product is not faulty 2 3 The...

Страница 19: ...tent permitted by law the Principal 4 2 1 excludes all implied warranties and conditions under statute or general law as to merchantability description quality suitability fitness for purpose or other...

Страница 20: ...by the machine from which that fax is sent and which confirms transmission of that fax in its entirety unless that local time is not a Business Day or is after 5pm on a Business Day in which case tha...

Отзывы: