Genquip Gi2000 Digital Inverter Petrol Generator

Activity/Procedure

If you do this ... 

Potential Hazards

This could happen ... 

Risk

Corrective Action

You can prevent by ... 

Operating generator in 
unventilated or enclosed 
area. 

Generator may over heat.
Carbon Monoxide (CO) 
poisoning from the toxic 
engine exhaust.

2
1

Operate generator in a well-
ventilated area. Do not operate 
in an enclosed location. 

Operate the generator in a 
careless/reckless manner. 

Unsafe operation could 
lead to serious injUry to 
you & others.

2

Review and understand all 
the operating instructions 
and warnings supplied by 
manufacture 

Refueling the generator 
while engine IS running.

Petrol vapors are highly 
fl ammable & could cause 
a fi re or explosion, which 
can cause serious injury. 

2

Always shut down engine 
and allow engine to cool 
suffi ciently. Open fuel 
cap slowly and have an 
appropriate fi re extinguisher 
present.

Over fi lling with fuel or fuel 
spillage while refueling. 

Fuel that is spilled whilst 
refueling can cause fi re or 
explosion. 

2

Open fuel cap slowly. Do 
not over fi ll fuel tank. If fuel 
spillage has occurred during 
refueling, clean the spillage 
completely and allow suffi cient 
time for any fuel vapors to 
dissipate. 

Tampering with the 
factory preset engine 
settings. 

Generator could over heat 
and engine could over 
speed, which may result 
in a fi re causing injury. 

2

Never attempt to tamper with 
factory settings, if in doubt 
contact Genquip. 

Failure to use the 
generator grounding point 
and correctly ground the 
generator. 

Generator unit could 
become electrically 
charged and could cause 
electrocution.

1

Make sure the generator 
is connected /grounded 
correctly. 

Exceeding the load 
capacity of the generator 
by attaching to many 
items, or items with very 
high load ratings.

Could overheat some 
items or their attached 
wiring causing fi re or 
electrical shock. 

1
2

Understand load ratings. 
Make sure that the total 
of electrical loads for all 
attachments does not 
exceed the load rating of the 
generator. Refer to a licensed 
electrician if in doubt. 

Operating generator 
with guards or protective 
covers removed. 

Exposed moving parts 
and hot surfaces could 
cause injury.

2

Never operate the generator 
without the factory fi tted 
guards or protective covers. 

Содержание Gi2000

Страница 1: ...page 1 Genquip Gi2000 Digital Inverter Petrol Generator Genquip Gi2000 Digital Inverter Petrol Generator Owners Manual...

Страница 2: ...page 2 Genquip Gi2000 Digital Inverter Petrol Generator Notes...

Страница 3: ...Maintenance 8 Spark Plugs 9 Engine Oil Replacement 10 Air Filter 11 Fuel Tank Filter 11 Genquip Safety 12 Operating Procedure 13 Visual Inspection Start Up Shutdown Potential Hazards 14 15 and Risk As...

Страница 4: ...5 Front Side Maintenance Cover 6 Recoil Starter 7 Engine Switch 8 Fuel Drain Hose 1 9 Fuel Drain Hose 2 10 240 Volt Sockets 11 Carry Handles 12 DC Circuit Protector 13 DC Socket 14 Fuel Saver Switch...

Страница 5: ...d the fuel tank capacity is 4 litres Check the Fuel Level 1 Make sure the generator is turned off by rotating the engine switch 7 to the off position Fig D 2 Check the fuel by a visual check Remove th...

Страница 6: ...m If the oil level falls below the safe operating level the engine will stop automatically Unless you re ll with oil the engine will not start again Note If the engine stalls or does not start turn th...

Страница 7: ...To start a cold engine move the choke lever to the start position In order to restart a warm engine leave the choke lever in the run position Fig I 5 Slowly pull the recoil starter 6 until you feel i...

Страница 8: ...ster Screen Recoil Starter Check operation Choke Handle Check operation Fuel System Check hose condition look for leaks Fittings Fasteners Check and Tighten Cooling System Air Check for obstructions E...

Страница 9: ...eposits using a wire brush 7 Check for discolouration of the top of the spark plug The standard colour should be tan colour 8 Check the spark plug gap Fig V Acceptable gap should be between 0 6mm 0 7m...

Страница 10: ...the oil ller neck 5 Once emptied tilt the generator back up and place into the generator up right position 6 Re ll with recommended oil Fill to the upper limit of the ller neck Fig W NOTE The recomme...

Страница 11: ...gine wear NOTE ALWAYS keep the lter clean at all times Fuel Tank Filter 1 Remove the fuel tank cap and lter 2 Clean the lter with solvent if damaged replace 3 Wipe the lter and insert it WARNING Be su...

Страница 12: ...r in a well ventilated area Keep all ammable materials and fuel away from the operating generator Caution of the hot exhaust must be observed as a generator can easily start a re always locates your g...

Страница 13: ...el level Air lter is not dusted and is free of debris Generator grounded Fuel cap on Start up Disconnect any electrical devices from the generator Generator is on a level surface Exhaust is free from...

Страница 14: ...n fuel cap slowly Do not over ll fuel tank If fuel spillage has occurred during refueling clean the spillage completely and allow suf cient time for any fuel vapors to dissipate Tampering with the fac...

Страница 15: ...Electrocution 1 Never operate the generator whilst wet or expose to damp conditions Clean the generator only when shut down and cooled down completely Do not spray water directly on or near any electr...

Страница 16: ...pressure air or vacuum system CAUTION DO NOT use a forceful spray of water to clean the generator Water can penetrate generator s electrical system which could reduce insulation resistance Possible g...

Страница 17: ...1600 Watts MAX OUTPUT 2000 Watts RUN TIME AT 1 2 RATED LOAD 7 hours RUN TIME AT RATED LOAD 4 5 hours RATED VOLTAGE 240 V RATED FREQUENCY 50 Hz RATED CURRENT 7A DC OUTPUT 12V 8A ENGINE TYPE 158F OHV A...

Страница 18: ...om the carburettor by loosening the drain screw on the carburettor oat chamber 3 Turn the fuel cock lever to OFF Start the engine and leave it run until it stops This will burn any remaining fuel in t...

Страница 19: ...may be ooded Leave the generator rest for 5 10 minutes and then try again following the instructions when doing so Alternatively if the choke lever is in full choke position start switch the choke to...

Страница 20: ...lied DC cables with the actual generator Mixed polarity Check to make sure that the DC cables are connected to the correct battery polarity terminals That is positive to positive and negative to negat...

Страница 21: ...sition Generator air lter may need cleaning Remove the air lter Check to make sure that the air lter is clean If required clean dry and re install the air lter Generator fuel lter may be blocked The i...

Страница 22: ...e caused by use of alternate or contaminated fuel 4 Damage to equipment caused by excessive vibration 5 Damage to engine due to surging from allowing fuel to run out 6 Damage to engine parts caused by...

Страница 23: ...page 23 Genquip Gi2000 Digital Inverter Petrol Generator Notes...

Страница 24: ...page 24 Genquip Gi2000 Digital Inverter Petrol Generator www genquip com au Genquip Warehouse 45 Riverside Road Chipping Norton NSW Call 1300 730 716...

Отзывы: