Engine Oil Replacement
1. Place the generator on a level surface and warm up the engine for several minutes.
Then stop the engine.
2. Loosen the side maintenance cover screw and remove the side maintenance cover.
3. Remove the oil fi ller cap.
4. Drain dirty oil into a container thoroughly by tilting the engine toward the oil fi ller neck.
5. Once emptied, tilt the generator back up and place into the generator up right position.
6. Refi ll with recommended oil. Fill to the upper limit of the fi ller neck
(Fig. W)
.
NOTE:
The recommended 4 stroke engine oil is 10W30 (multi viscosity) 4 stroke oil.
CAUTION:
Check that no foreign material, debris, dust
enters the crankcase.
7. Reinstall the oil fi ller cap.
CAUTION:
Be sure to install securely to prevent from
falling off during operation.
8. Reinstall the side maintenance cover and tighten the cover screw.
Oil Filler
Cap
Full Oil
Level
Low Oil
Level
Figure W.