7. OPERATIONAL PARAMETERS

All programmable functions of the board depend on the DIP-SWITCHES “

DP

”. The following table shows the different options.

Dip-switch

Description

Deceleration speed:

 use this dip-switch to adjust the motor speed during the deceleration phase.

High speed

Low speed

Length of the decelerated section: 

use this dip-switch to adjust the length of the decelerated section on two steps.

The decelerated section corresponds to 5% of the memory stored opening, it is recommended for gates 

having a length over 3 meters.

The decelerated section corresponds to 15% of the memory stored opening, it is recommended for gates 

with a length below 3 meters.

Automatic closure: 

you can select between two options: automatic gate re-closure or gate closure after a closing pulse. The 

pause time is defined during the board programming phase.

Automatic closure disabled

Automatic closure enabled

Safety device operation:

 use this dip-switch to select if the safety devices connected to the “

FSW

” input must be only active 

during the gate closing phase or during the closing and opening phase of the gate. 

Safety devices only active during gate closing phase

Safety devices active during both closure and opening

OPENA  input:

  use  this  dip-switch  to  select  between  two  operations  of  the  devices  connected  to  the  “

OPENA

”  

command.

Every pulse of the command reverses the gate movement: Opens/Closes/Opens/...

The  reversal  of  the  gate  movement  is  spaced  by  STOP  commands:  Opens/Stops/Closes/Stops/

Opens/...

Reversal at closure:

 if you activate this function, at the end of the closing phase, the gate performs a brief reversal of motion. 

In this way it discharges the release device, making its operation easier, if necessary.

Reversal at closure disabled

Reversal at closure enabled

  Set the DIP-SWITCHES only after having cut power. Otherwise you can jeopardize the operation of the control unit.

8. VIRTUAL ENCODER OPERATION

Thanks to the motor control circuit (virtual encoder) this control unit, if correctly installed and adjusted, reduces the number of 

accessories necessary for an installation conforming to current safety standards.

The motor control is always active during gate movement and operates according to the following procedures:

Gate at opening

If the encoder operates during the gate opening movement, the consequence is a brief reversal of movement, then the control 

unit goes into STOP condition, disabling thus any automatic functions to make the obstacle removal possible. To resume normal 

memory-stored cycle, send an OPEN impulse after having removed the obstacle.

Содержание SPRINT 11 SW

Страница 1: ...SPRINT 11 SW Istruzioni per l uso Instructions for use Instructions pour l usager Instrucciones para el uso Gebrauchsanleitung Gids voor de gebruiker...

Страница 2: ...ct underwent a test in a typical uniform configuration all products manufactured by GENIUS S p A Grassobbio October 22 2009 Managing Director D Gianantoni INDEX 1 GENERAL CHARACTERISTICS page 13 2 TEC...

Страница 3: ...trimmer adjustable Terminal board inputs Mains power supply Travel limit device at opening Travel limit device at closing STOP Safety devices OPEN A OPEN B Batteries Rapid connector Battery charger Ra...

Страница 4: ...LED for OPEN B radio input status JP3 Quick fit connector for battery kit on board the machine FSW LED for FSW input status DP Programming dip switch STOP LED for STOP input status POWER Trimmer for...

Страница 5: ...nnected in series If safety devices are not connected these two terminals must be jumper connected 5 2 4 Stop Terminals STOP COM Normally closed contact Connect any pulse generator i e push button key...

Страница 6: ...T Only common lead batteries can be used having a capacity not exceeding 4Ah The operation of the battery kit is described in the following paragraph The compartment housing the remote batteries must...

Страница 7: ...e Safety devices active during both closure and opening OPENA input use this dip switch to select between two operations of the devices connected to the OPENA command Every pulse of the command revers...

Страница 8: ...top gate motion pressing the RESET push button and reverse the two power cables of the motor connected to terminals OP CL of terminal board CN2 When the closing travel limit device has been reached th...

Страница 9: ...Put the two radio controls frontally into contact On the memory stored radio control press and hold down the push button relating to the channel you wish to transfer the radio control LED lights up o...

Страница 10: ...Ds LED ON OFF OPA OPEN A radio command active OPEN A radio command inactive OPB OPEN B radio command active OPEN B radio command inactive FSW Safety devices free Safety devices engaged STOP STOP comma...

Страница 11: ...ffect No effect Stops operation No effect Stops operation and resumes after release STEP BY STEP AUTOMATIC LOGIC DIP SWITCH 3 ON DIP SWITCH 5 ON GATE STATUS INPUTS OPEN A OPEN B STOP PHOTOCELLS DIP SW...

Страница 12: ...ffect Stops operation No effect Stops operation and resumes after release STEP BY STEP MANUAL LOGIC DIP SWITCH 3 OFF DIP SWITCH 5 ON GATE STATUS INPUTS OPEN A OPEN B STOP PHOTOCELLS DIP SWITCH 4 OFF D...

Отзывы: