background image

User Manual

24 Port Gigabit Layer 2 Managed PoE Switch

10

SFP Port Connection

The IP16GESP2 only supports Gigabit fiber module. The process of installing a fiber 

module on a switch is as follows:

•  Firstly, grasp the optic fiber module from the side, insert it smoothly along the 

SFP port slot until the optic fiber module and switch are in close contact.

•  Secondly, confirm the Rx and Tx ports of the fiber module when connecting. 

Insert one end of the fiber into the Rx and Tx ports, ensuring that the Tx and Rx 

ends of the interface are connected correctly and the other end of the fiber is 

connected to another device.

•  Thirdly, please check the corresponding indicator light status after power on. 

If the light is blinking that means the link is properly connected, if the light is 

off , the link has failed to connect. Please check the line to confirm that the 

corresponding equipment is enabled.

Note: 

•  Do not allow excessive bending of the fiber, the radius of curvature should not 

be less than 10cm.

•  Ensure the cleanliness of the fiber surface.

•  Please do not look directly into the optical fiber connector with your eyes as 

this may cause eye injury.

Before Powering On

•  Check whether the outlet power supply meets the switch specifications.

•  Check the power, switches, racks and other equipment have been properly 

grounded.

•  Check whether the switch and other network devices are connected properly.

Device Initialisation

The switch automatically initialises when the power switch is turned on. Indicator 

will appear the following situation:

•  After the power is turned on, the power indicator remains on, the other 

indicator is off at this time.

•  After about 1 second, all lights except for the power light turn on for about 35 

seconds and then turn off.

•  When the SYS light flashes, the system runs normally.

•  Port LED’s indicates the connection status of each port, indicating that the 

switch has started to work normally

Содержание IP24GESP2

Страница 1: ...urther reference All the examples and pictures used here are for reference only The contents of this manual are subject to change without notice Please read these instructions carefully before operating the unit and keep for further reference 24 Port Gigabit Layer 2 Managed PoE Switch IP24GESP2 ...

Страница 2: ...arance 4 Back Panel Switch Appearance 5 2 0 Product Installation 6 Installation Safety Precautions 6 Product Installation 8 3 0 Hardware Connection 9 SFP Port Connection 10 Before Powering On 10 Device Initialisation 10 Web Login 11 4 0 Hardware Specifications 13 5 0 Software Specifications 14 ...

Страница 3: ...ons AI VLAN AI Extend 1 8 port 250m PoE distance AI PoE AI Q0S video priority Support based on the port number IP address MAC address and user access restrictions Supports PoE and settings for PoE port priority Supports L2 Layer 2 L4 Layer 4 packet filtering Supports multi cast suppression Supports loop protection root bridge protection TC protection BPDU protection and BPDU filtering Supports bro...

Страница 4: ...rove network performance AI Power Supply Detect PD power failure and restart dead equipment Indicator Title Colour Work State Description PWR Power indicator Red Solid Power is normal Off No power the power switch is not turned on power supply is abnormal PoE PoE power indicator Yellow Solid The corresponding RJ45 port is connected to the powered device and the power supply is normal Off The corre...

Страница 5: ... restarts When the switch is powered on press the button for 5 seconds or more to release the button device to enter the reset status when SYS lights up again the device resets successfully Console Port The Console port is used for connecting to the serial port of a computer or other terminal to manage or configure the switch Back Panel Switch Appearance Includes power socket and ground terminal a...

Страница 6: ...f it is not charged do not open it Before cleaning the switch pull out the power plug of the switch Do not wipe with a moist fabric and do not use liquid to clean Temperature and Humidity In order to ensure long term stable operation of the switch and prolong its working life please maintain a certain temperature and humidity in the environment it s placed in Excessively high or too low ambient hu...

Страница 7: ... high frequency high power high current equipment such as wireless transmitters Take electromagnetic shielding measures when necessary Lightning Protection When a lightning strike occurs a strong current is generated in an instant and the air in the discharge path is instantaneously heated to 20 000 degrees Celsius which can instantaneous cause a large current that is enough to cause fatal damage ...

Страница 8: ...ack and be supported by the bracket Screw the L shaped bracket to the guide groove fixed on both ends of the rack to ensure that the switch is stable and horizontally installed on the rack Note A good grounding rack is a piece of anti static anti leakage anti jamming and lightning protection equipment that is an important guarantee to ensure that the rack ground wire is properly installed Make sur...

Страница 9: ...be used for IEEE802 3af or IEEE802 3at standards powered devices such as APs bridges and network cameras Note When the switch is connected to workstations servers routers or other Ethernet devices the cable length should be within 100 meters The Auto MDI MDIX Ethernet interface is enabled by default Category 5 the standard network cable or crossover cable can be used for Ethernet connection Do not...

Страница 10: ...t the corresponding equipment is enabled Note Do not allow excessive bending of the fiber the radius of curvature should not be less than 10cm Ensure the cleanliness of the fiber surface Please do not look directly into the optical fiber connector with your eyes as this may cause eye injury Before Powering On Check whether the outlet power supply meets the switch specifications Check the power swi...

Страница 11: ...ged PoE Switch 11 Web Login Step 1 In the normal operation of the device connect the computer to the switch s RJ45 port by network cables Step 2 Manually changed the computer IP address to 192 168 254 X X is 2 254 subnet mask is 255 255 255 0 ...

Страница 12: ...uter s browser type 192 168 254 1 in the address box hit the Enter key Step 4 Enter the default username and password admin and then click Login Step 5 Entered the switch web management interface successfully when you see picture as below you can begin to configure the switch ...

Страница 13: ... port 2 gigabit SFP 1 Console PoE 24 10 100 1000Mbps RJ45 port support PoE Max 150W Single port max 46W LED s 26 Link Act LED s 24 PoE LED s 1 SYS LED 1 Power LED Performance Forwarding mode Store and forward Bandwidth 52Gbps Packet forwarding rate 38 688Mpps 8K MAC address table Lightning Protection 6KV Input 100 240V 50 60Hz Dimensions 440 180 44 mm ...

Страница 14: ...curity port isolation Supports CPU protection PoE Management Supports PoE power limit Supports PoE chip status view Supports setting PoE port priority Supports setting PoE power supply time period Access Control ACL Supports L2 Layer 2 L4 Layer 4 packet filtering Supports port mirroring port redirection flow rate limiting QoS re marking Quality of Service QoS Supports 8 port queue Supports port pr...

Страница 15: ...Sales 44 0 1707 330541 Enquiries sales genieproducts co uk Website www genieproducts co uk ...

Отзывы: