Page
D - 12
Document 57.0008.7200 - 05/2007
Handler with telescopic boom
GTH-3512
MAINTENANCE
■
D-3.8
CHECKING THE OIL LEVEL IN THE
TANK
DANGER
Fine jets of hydraulic oil under pressure can
penetrate the skin. Do not use your fingers, but a
piece of cardboard to detect oil leaks.
Check the hydraulic oil level (visually) through the
special level
fitted into the tank.
When necessary, add new oil through filler
.
CAUTION
Check the oil level with handler set to transfer position
(lowered boom and retracted telescopic element).
If oil must be changed, proceed as follows:
1
Stop the machine on a level ground and make sure
the parking brake is engaged.
2
Release the pressure from the hydraulic circuit.
3
Place a container of suitable size under the drain
plug, placed in the lower part of the reservoir, and
collect any oil leaks.
4
Remove the drain plug and allow oil to flow out into
the container.
5
Remove the inspection cover of tank
.
6
Carefully wash the tank with Diesel oil and blow a
jet of compressed air.
7
Refit the drain plug and the inspection cover.
8
Add new oil by making sure that it matches the
recommended type indicated in paragraph D-5.2.2.
until it is level with
.
PROTECT THE
ENVIRONMENT
The handling and disposing of used oils can be
ruled by local or national regulations. Address to
authorised centres.
SERVICE INTERVAL
Running-in _________
Within the first
10
hours
Ordinary ____________________
Every
50
hours
SERVICE INTERVAL
Running-in ____________________________
None
Ordinary ________________
Every
1000
hours
Содержание GTH-3512
Страница 2: ...Courtesy of Crane Market...