Page
E - 4
Document 57.0008.7200 - 05/2007
Handler with telescopic boom
GTH-3512
PROBLEMS AND TROUBLESHOOTING
THE BOOM DOES NOT MOVE
CHECKING THE MICRO-
SWITCHES WHEN THE DLE IS IN
ALARM, THE BOOM IN/OUT
MOVEMENTS, THE OUTRIGGER
UP-MOVEMENT AND THE
MACHINE SWAY FUNCTION
REMAIN ACTIVATED
CHECKING THE MICRO-
SWITCHES WITH THE BOOM
RAISED 2 METRES ABOVE THE
GROUND THE OUTRIGGER UP-
MOVEMENT AND THE MACHINE
SWAY FUNCTION REMAIN
ACTIVATED
THE DLE MOMENT LIMITING
SYSTEM IS IN ALARM
ALARM MESSAGES OF THE DLE
MOMENT LIMITING SYSTEM
SHOWN ON THE DISPLAY
• Fuse blown (
F19 - 10 A
)
• “ROAD/JOBSITE” switch set to
“ROAD”
• Check that the connectors are
correctly plugged in the actuator
• Check that the connectors are
correctly plugged in the actuator
• Fuse blown (
F25 - 10 A
)
• System fault
1
E2PROM error
2
Value read from
CELL 1
higher than
the maximum permissible
3
Value read from
CELL 2
higher than
the maximum permissible
• Check the fuse and replace if
necessary
• Switch to “JOBSITE”
• If the connectors are plugged in
correctly, contact the GENIE
Technical Assistance.
• If the connectors are plugged in
correctly, contact the GENIE
Technical Assistance.
• Check the fuse and replace if
necessary.
• Turn power off and on and RESET
the system. If the error message is
still shown, contact GENIE to re-
calibrate the unit.
• Check the wiring between control
panel and load cell
• Check that the load cell is fixed
correctly
• Check the connecting cable or the
connectors is/are not shorted
• If the error message is still shown,
contact the GENIE Service Centre and
have the load cell be checked.
• Check the wiring between control
panel and load cell
• Check that the load cell is fixed
correctly
• Check the connecting cable or the
connectors is/are not shorted
• If the error message is still shown,
contact the GENIE Service Centre and
have the load cell be checked.