Part No. 33424
Genie AWP
9
Operator’s Manual
Fourth Edition
Function Tests
1 Select a test area free of obstructions.
2 Connect appropriate power source.
3 Turn the key switch to the
ON
position.
Result: The power light should come on.
4 Pull out the red Emergency Stop button to
the
ON
position.
5 Select an outrigger
and slide it into a
base socket until the
outrigger lock pin
snaps into place.
Bring the outrigger
leveling jack into firm
contact with ground.
6 Check the interlock
display lights at the
ground controls.
Confirm that the
corresponding light
is on.
7 Repeat procedure for
each of the remaining
outriggers.
Test Emergency Stop
8 Use the bubble level and adjust leveling jacks
until the machine base is level.
9 Twist to release the red Emergency Stop button
at the platform controls.
10 Push in the red Emergency Stop button at the
ground controls to the
OFF
position.
PRE-OPERATION INSPECTION & FUNCTION TESTS
11 Push in the control activate button and rotate
the up/down switch in the direction of intended
travel.
Result: Up/Down
functions should not
operate.
12 Push in the red
Emergency Stop
button at the platform
controls to the
OFF
position.
13 Pull out the red Emergency Stop button at the
ground controls to the
ON
position.
14 Push in the control activate button and rotate
the up/down switch in the direction of intended
travel.
Result: Up/Down functions should not operate.
Test Outrigger Interlock
15 Twist to release the red Emergency Stop button
at the platform controls.
16 Pull out the red Emergency Stop button at the
ground controls to the
ON
position.
Result: Up/Down functions should operate.
17 Unscrew one leveling jack until the
corresponding interlock display light turns off.
Result: Up/Down functions should not operate.
18 Return the leveling jack to previous setting and
check the bubble level.
19 Repeat procedure for each outrigger.
Test Manual Lowering
20 Raise platform slightly.
21 Activate the manual lowering valve located on
the hydraulic power unit.
Result: Platform should descend.