APPENDIX 1
DMX Addressing Chart
Value
DMX
256
128
4
6
32
6
1
8
4
2
1
9
8
7
6
5
4
3
2
1
Switch
Dip
DMX512 Dip switches and values have the following relationship:
SHIVA
Unit 14
Unit 13
Unit 12
Unit 11
Unit 10
Unit 9
Unit 8
Unit 7
Unit 6
Unit 5
Unit 4
Unit 3
Unit 2
Unit 1
Address
79
73
67
61
55
49
43
37
31
25
19
13
7
1
9
8
7
6
5
4
3
2
1
N
O
9
8
7
6
5
4
3
2
1
N
O
9
8
7
6
5
4
3
2
1
N
O
9
8
7
6
5
4
3
2
1
N
O
9
8
7
6
5
4
3
2
1
N
O
9
8
7
6
5
4
3
2
1
N
O
9
8
7
6
5
4
3
2
1
N
O
9
8
7
6
5
4
3
2
1
N
O
9
8
7
6
5
4
3
2
1
N
O
9
8
7
6
5
4
3
2
1
N
O
9
8
7
6
5
4
3
2
1
N
O
9
8
7
6
5
4
3
2
1
N
O
9
8
7
6
5
4
3
2
1
N
O
9
8
7
6
5
4
3
2
1
N
O
9
8
7
6
5
4
3
2
1
N
O
9
8
7
6
5
4
3
2
1
N
O
9
8
7
6
5
4
3
2
1
N
O
9
8
7
6
5
4
3
2
1
N
O
9
8
7
6
5
4
3
2
1
N
O
9
8
7
6
5
4
3
2
1
N
O
9
8
7
6
5
4
3
2
1
N
O
9
8
7
6
5
4
3
2
1
N
O
9
8
7
6
5
4
3
2
1
N
O
9
8
7
6
5
4
3
2
1
N
O
9
8
7
6
5
4
3
2
1
N
O
9
8
7
6
5
4
3
2
1
N
O
9
8
7
6
5
4
3
2
1
N
O
9
8
7
6
5
4
3
2
1
N
O
Dip Switches
SHIVA
Address Dip Switches
Unit 15
Unit 16
Unit 17
Unit 18
Unit 19
Unit 20
Unit 21
Unit 22
Unit 23
Unit 24
Unit 25
Unit 26
Unit 27
Unit 28
85
91
157
151
145
139
133
127
121
115
109
103
97
163
11
This means, for instance, that the first DMX dip switch has a DMX value of 1,
and the fifth DMX dip switch has a value of 16.
TM
TM
Since each Shiva-150R/200R/250R has 6 channels, starting
addresses would be set as follows: First scanner starting address
= 1; Second scanner starting address = 7, etc.
Use a ball-point pen or toothpick to set dip switch addresses
appropriately. See the guide DMX512 Basics for more
information. For convenience, Shiva-150R/200R/250R starting
addresses for 28 units and corresponding DMX dip switch settings
are listed below.
4
2. Remove lamp from
packagin g. Re ad
lamp instructions. D
o n ot to uch la mp bu lb
with bare hands, as this could damage
the lamp. Grasp the lamp stem and
wear lint-free gloves.
1. Loosen two screws (B6) on the slide-ou t
lamp holder ( B2). D on't lo osen th e m iddle
screw (B3). Pull the lamp holder (B2) out
as far as possible, about 10 cm.
Caution! Lamp and meta l componen ts g et hot du ring operat ion. Alw ays
disconnect power and allow unit to cool before opening the unit cover.
Lamp Installation
B11
B10
B9
B8
B7
B6
B5
B4
B3
B2
B1
For the sake of brevity, this manual refers to "Shiva-
TM
TM
150R/200R/250R " scanner. Actually, "Shiva-150R/200R/250R "
TM
refers to the three scanners with similar functions: Shiva-200R
scanner uses HSD-200 lamp which has a 2000-hour lamp life.
TM
Shiva-250R scanner uses EHJ 64655 G6.35 24V/250W (50-hour)
TM
or EHJ 64657 G6.35 24V/250W (300-hour) lamp. Shiva-150R
uses PHILIPS CDM-SA/T 150W/942 . Always use the correct lamp
for your unit.
TM
3a. For Shiva-150R scanner: Note that the CDM-SA/T
150W/942 lamp stem has two pegs, one thicker than the other.
Match the pegs with the holes in the lamp socket. Insert the
pegs into the lamp socket.
TM
3b. For Shiva-200R scanner: Use HSD-200 lamp ,Same as
above procedure.
TM
3c. For Shiva-250R scanner: Use either EHJ 64655 G6.35
24V/250W (50-hour) or EHJ 64657 G6.35 24V/250W (300-
hour) lamp. Both of these lamps have two pegs of the same
size. Insert pegs into the lamp Socket.
4. Make sure the lamp is in straight. Push the lamp mechanism (B2)
straight back into place and fasten screws (B6) on the lamp
holder (B2). If you feel strong resistence when pushing the lamp