3. Dispose lamps properl y. Ke ep u sed la mps away from c hildren and
animals.
2. With one hand on the lamp socket and the other on the stem of the lamp
bulb, pull the lamp stem away from the socket.
Lamp Removal
To remove lamps , follo w t he directio ns bel
ow. Alw ays a llow un it to cool
before changing lamps or opening the unit cover.
1. Loosen two screws (B6) on the slide-out lamp holder (B2). Do no t loose n
the middle screw (B3) . Pu ll th e lam p hold er (B 2) out as fa r as possi ble,
about 10 cm.
Maintenance
8
Warning: Disconnect power and let unit cool before handling. Never open
unit cover when in use. Keep away from water and other liquids.
Lamps have special characteristics that should be observed to prolong
their use. Wait about ten minutes after disconnecting electric power to
TM
Shiva-150R/200R scanner before supplying power again. The
CDM-
SA/T 150W/942 and HSD-200 lamp will not relight immediately after
being turned off. Wait about one minute after disconnecting power to
TM
Shiva-250R scanner before supplying power again. Even though
halogen lamps, like EHJ 64657 G6.35 24V/250W, restart quickly after
being extinguished, wait one minute to protect scanner electronics.
To maintain maximum brightness, clean the unit regularly with a damp
cloth or glass cleaner.
1. Wipe lens clean regularly.
2. Keep internal optical path free from dust or cobwebs.
3. Clean internal parts once a year with a brush and strong vacuum
#4 On
#5 Off
X-axis (pan) movements
progress from left to right.
X-axis (pan) movements progress from
right to left.
#5 On
#6 Off
Y-axis (tilt) movements progress
from low to high.
Y-axis (tilt) movements progress from
high to low.
#6 On
#7 Off
Exterior control mode. For use
with any DMX controller.
#7 On
Focus assistance is activated; a gobo
appears for easy focusing.
Function Dip Switch Diagram (Cont.)
6
5
4
3
2
1
N
O
7
6
5
4
3
2
1
N
O
8
6
5
4
3
2
1
N
O
7
6
5
4
3
2
1
N
O
8
6
5
4
3
2
1
N
O
7
6
5
4
3
2
1
N
O
8
6
5
4
3
2
1
N
O
7
6
5
4
3
2
1
N
O
8
6
5
4
3
2
1
N
O
7
6
5
4
3
2
1
N
O
8
6
5
4
3
2
1
N
O
7
6
5
4
3
2
1
N
O
8
6
5
4
3
2
1
N
O
7
6
5
4
3
2
1
N
O
8
6
5
4
3
2
1
N
O
7
6
5
4
3
2
1
N
O
8
6
5
4
3
2
1
N
O
7
6
5
4
3
2
1
N
O
8
6
5
4
3
2
1
N
O
7
6
5
4
3
2
1
N
O
8
#8 Off
Exterior control mode. For use
with any DMX controller.
#8 On
DMX512 signal termination; activate this
function dip switch on the last in a series
of DMX units to maintain a clear signal.
7
Service Dip Switches
For general use, do not activate Service dip switches.
TM
Note that Shiva-250R scanner does not have service dip switches.
Service dip switche s ar e aid s to technicia ns worki ng on Shiva-150R/2 0 0R
scanner. They have two functions, both of which are explained below.
Service Dip Switch Diagram
Motor power supply is "off" while lamp is lit.
#1 On
Motor power supply is "on" while lamp is not lit.
#2 On
2
1
N
O
2
1
N
O
2
1
N
O
2
1
N
O
TM
#4 Off
Exterior control mode. For use
with any DMX controller.
Self-test function; scanner runs through
a pre-set pattern of actions.