CHAPTER 2 SPECIFICATIONS

1.Vout voltage programming
2.Iout voltage programming (*13)
3.Vout resistor programming
4.Iout resistor programming (*13
5.On/off control
6.Output current monitor (*13)
7.Output voltage monitor
8.Power supply OK signal
9.Parallel operation
10.Series operation
11.CV/CC indicator
12.Enable/Disable
13.Local/Remote analog control
14.Local/Remote analog indicator

)

2.5 ANALOG PROGRAMMING AND MONITORING

---

---

---

---
---

---

---
---
---

---
---
---
---
---

0~100%, 0~5V or 0~10V, user selectable. Accuracy and linearity: +/-0.5% of rated Vout.
0~100%, 0~5V or 0~10V, user selectable. Accuracy and linearity: +/-1% of rated Iout.
0~100%, 0~5/10Kohm full scale, user selectable. Accuracy and linearity: +/-1% of rated Vout.
0~100%, 0~5/10Kohm full scale, user selectable. Accuracy and linearity: +/-1.5% of rated Iout.
By electrical Voltage: 0~0.6V/2~15V or dry contact, user selectable logic.
0~5V or 0~10V, user selectable. Accuracy: +/-1%.
0~5V or 0~10V, user selectable. Accuracy : +/-1%.
4~5V-OK, 0V-Fail. 500ohm series resistance.
Possible , up to 4 units in master/slave mode with two wires current balance connection.
Possible (with external diodes), up to 2 units.
Open collector. CC mode: On, CV mode: Off. Maximum voltage: 30V, maximum sink current: 10mA.
Dry contact. Open: Off, Short: On. Max. voltage at Enable/Disable in: 6V.
By electrical signal or Open/Short: 0~0.6V or short: Remote, 2~15V or open: Local.
Open collector. Local: Open, Remote: On. Maximum voltage: 30V, maximum sink current: 10mA.

2.1 OUTPUT RATING

1.Rated output voltage(1*)
2.Rated output current (*2)
3.Rated output power

V
A

W

MODEL

GEN 8-400

8

400

3200

10-330

10

330

3300

15-220

15

220

3300

20-165

20

165

3300

30-110

30

110

3300

40-85

40
85

3400

60-55

60
55

3300

80-42

80
42

3360

100-33

100

33

3300

150-22

150

22

3300

200-16.5

200

16.5

3300

300-11

300

11

3300

600-5.5

600

5.5

3300

9

2.2 INPUT CHARACTERISTICS

Single Phase models:
3-Phase, 200V models:
3-Phase, 400V models:

---

---

%

Single Phase models: 170~265V, 47~63Hz

Single Phase models: 0.99@200Vac, rated output power. 3-Phase models: 0.95@200/380Vac, rated output power.

3-Phase, 200V models: 170~265Vac, 47~63Hz
3-Phase, 400V models: 342~460Vac, 47~63Hz

Single-Phase and 3-Phase 200V models: Less than 50A
3-Phase 400V models: Less than 20A

V

8

10

15

20

30

60

40

150

100

80

600

200

300

24.0
14.5

7.2

24.0
14.5

7.2

24.0
14.5

7.2

24.0
14.5

7.2

23.0
14.0

7.0

24.0
14.5

7.2

23.0
13.6

6.8

23.5
14.0

7.0

23.0
13.7

6.8

23.0
13.7

6.8

23.0
13.7
6.8

23.0
13.9

7.0

23.0
13.8

6.9

3.Power Factor (Typ)
4.Ef

ficiency

(*4)

5.Inrush current (*5)

2.Maximum

Input current

at 100% load

1.Input voltage/freg. (*3)

---

A

82

83

83

83

86

86

87

88

88

88

87

87

87

8

10

15

30

20

40

60

80

150

100

200

300

600

2.3 CONSTANT VOLTAGE MODE

1.Max. Line regulation (*6)
2.Max. Load regulation (*7)
3.Ripple and noise (p-p , 20MHz) (*8)
4.Ripple r.m.s., 5Hz~1MHz
5.Temperature coef

ficient

6.Temperature stability
7.Warm-up drift
8.Remote sense compensation/wire
9.

11.Transient response time

12.Hold-up time (Typ)

Up-prog. response time, 0~Vomax.(*9)

10.Down-prog. response time

Full load(*9)

No load(*10)

V

---
---

mV
mV

---
---

V

mS

PPM/ C

o

mS

mS

mS

0.01% of rated output v2mV

0.015% of rated output v5mV

60

8

60

8

60

8

60

8

60

8

80
25

100

25

500
120

60

8

60

8

100

25

275

75

300
100

100PPM/ C from rated output voltage, following 30 minutes warm-up.

O

0.05% of rated Vout over 8 hrs interval following 30 minutes warm-up. Constant line, load & temp.

Less than 0.05% of rated output v2mV over 30 minutes following power on.

2

2

2

2

5

5

5

5

5

5

5

5

200

5

80

250

20

100

500

600

700

800

160

900

1000

300

150

1100

1200

1500

2000

500

3000

3000

4000

Time for output voltage to recover within 0.5% of its rated output for a load change 10~90% of rated output
current. Output set-point: 10~100%, Local sense.
Less than 1mS, for models up to and including 100V. 2mS, for models above 100V.
10mSec for Single-Phase and 3-Phase 200V models, 6mSec for 3-Phase 400V models. Rated output power.

V

8

10

15

20

40

30

60

80

100

150

200

600

300

2.4 CONSTANT CURRENT MODE

1.Max. Line regulation (*6)
2.Max. Load regulation (*11)
3.Load regulation thermal drift
4.Ripple r.m.s. 5Hz~1MHz (*12)
5.Temperature coef

ficient

6.Temperature stability
7.Warm-up drift

---

---

---

---

---

mA

PPM/ C

o

0.01% of rated output c2mA

0.02% of rated output c5mA

100PPM/ C from rated output current, following 30 minutes warm-up.
0.05% of rated Iout over 8hrs interval following 30 minutes warm-up. Constant line, load & temperature.

O

Less than 0.1% of rated output current over 30 minutes following load change.

1200

880

660

1300

200

300

60

70

100

80

40

20

10

8~20V model: Less than +/-0.5% of rated output current over 30 minutes following power on.

30V~600V model: Less than +/-0.25% of rated output current over 30 minutes following power on.

9

Содержание GEN10-330

Страница 1: ...Programmable DC Power Supplies 3 3kW in 2U Built in RS 232 RS 485 Interface Advanced Parallel Operation Optional Interface Compliant LAN IEEE488 2 SCPI GPIB Multi Drop Isolated Analog Programming...

Страница 2: ...v H GENESYSTM GEN 3 3kW SERIES POWER SUPPLIES USER MANUAL This Manual Covers Models GEN8 400 GEN10 330 GEN15 220 GEN20 165 GEN30 110 GEN40 85 GEN60 55 GEN80 42 GEN100 33 GEN150 22 GEN200 16 5 GEN300 1...

Страница 3: ...This page intentionally left blank...

Страница 4: ......

Страница 5: ...us Substances Notes Concentration Values of Toxic and Hazardous Substances Elements wt Subpart Name This information sheet was prepared based on People s Republic of China Management Methods for Contr...

Страница 6: ...RISTICS 2 13 OUTLINE DRAWINGS 3 1 GENERAL 3 2 PREPARATION FOR USE 3 3 INITIAL INSPECTION 3 4 RACK MOUNTING 3 4 1 To install the power supply in a rack 3 4 2 Rack mount slides 3 5 LOCATION MOUNTING AND...

Страница 7: ...5 3 2 Activated OVP protection indications 5 3 3 Resetting the OVP circuit 5 4 UNDER VOLTAGE LIMIT UVL 5 4 1 Setting the UVL level 5 5 FOLDBACK PROTECTION 5 5 1 Setting the Foldback protection 5 5 2...

Страница 8: ...General guides 7 7 2 Command set categories 7 7 3 Initialization control commands 7 7 4 ID control commands 7 7 5 Output control commands 7 7 6 Global output commands 7 7 7 Status control commands 7...

Страница 9: ...This page intentionally left blank...

Страница 10: ...e occurring as a result ofthe buyer s circuitry or the buyer s supplied products No other warranty is expressed or implied WARRANTY SERVICE This product must be returned to an authorized Nemic Lambda...

Страница 11: ...S UK TM NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protec...

Страница 12: ...ch case the user will be required to correct the interference at his own expense Instruction manual symbol The instrument will be marked with this symbol when it is necessary for the user to refer to...

Страница 13: ...N PE und das 3 phasige Ger t mit 4 Leitern L L2 L3 PE angeschlossen werden Der PE Anschluss ist an einen festen Erder anzuschliessen Bei Festverdrahtung des Ger tes ist sicherzustellen dass der PE An...

Страница 14: ...nnung AC Dieses Warnaufschrift weist auf eine Gefahr hin die eine berpr funganweisung nach sich zieht Nichteinhaltung kann zu Personensch den f hren Dieser Warnhinweis darf nicht bersprungen werden un...

Страница 15: ...The rear panel includes the necessary connectors to control and monitor the power supply operation by remote analog signals or by the built in serial communication RS232 485 GPIB programming and Isol...

Страница 16: ...ply The output voltage and the current limit can be programmed by analog voltage or by resistor and can be monitored by analog voltage The power supply output can be remotely set to On or Off and anal...

Страница 17: ...B25 plug kit AMP 749809 9 Strain relief forAC cord Output terminal shield Plastic legs for bench mounting AC cables are not provided with the power supply Refer to Table1 2 for recommended AC input ca...

Страница 18: ...7 2 24 0 14 5 7 2 24 0 14 5 7 2 24 0 14 5 7 2 23 0 14 0 7 0 24 0 14 5 7 2 23 0 13 6 6 8 23 5 14 0 7 0 23 0 13 7 6 8 23 0 13 7 6 8 23 0 13 7 6 8 23 0 13 9 7 0 23 0 13 8 6 9 3 Power Factor Typ 4 Ef cie...

Страница 19: ...ature 2 Storage temperature 3 Operating humidity 4 Storage humidity 5 Altitude 0 50 C 100 load 20 85 C 20 90 RH no condensation 10 95 RH no condensation Maximum 3000m Derate output current by 2 100m a...

Страница 20: ...ated output voltage 11 For load voltage change equal to the unit voltage rating constant input voltage 12 For 8V 15V models the ripple is measured at 2V rated output voltage and rated output current F...

Страница 21: ...phase shown 5 Chassis slides GENERAL DEVICES P N CC3001 00 S160 or equivalent mounting holes 10 32 marked A 6 Bus Bars enclosure for 60V to 600V 7 Mounting holes for 19 rack Use M6x16 screws to x the...

Страница 22: ...re not scratched or cracked Keep all packing material until the inspection has been completed If damage is detected file a claim with carrier immediately and notify the Lambda sales or service facilit...

Страница 23: ...single or three phase 47 63Hz or from a nominal 380V to 415V three phase 47 63Hz The input voltage range and current required for each model is speci ed in Chapter 2 Ensure that under heavy load the...

Страница 24: ...ipped wires through the strain relief WARNING AC input cord is not provided with power supply WARNING Some components inside the power supply are at AC voltage even when the On Off switch is in the Of...

Страница 25: ...oming inspection check Refer to Fig 4 1 and Fig 4 2 for the location of the controls indicated in the procedure 1 Ensure that the power supply is configured to the default setting AC On Off switch at...

Страница 26: ...y Ensure that the front panel CURRENTLED is on 6 Turn off the front panelAC power switch 7 Remove the shunt from the power supply output terminals Refer to Section 5 3 for explanation of the OVPfuncti...

Страница 27: ...Baud Rate 2 Using The CURRENT adjust encoder check that the Baud Rate can be set to 1200 2400 4800 9600 and 19200 3 8 8 Address Setting 3 8 9 Baud Rate Setting 3 9 CONNECTING THE LOAD 18 Shorting the...

Страница 28: ...2 10 8 6 4 2 0 2 526 1 589 0 9994 0 6285 0 3953 0 2486 0 1564 0 0983 10A 40 60 100 160 250 400 600 1000 20A 20 30 50 80 125 200 300 500 50A 8 12 20 32 50 80 125 200 100A 4 6 10 15 25 40 60 100 200A 2...

Страница 29: ...y be harmful to the power supply Adiode should be connected across the output The diode voltage and current rating should be greater than the power supply maximum output voltage and current rating Con...

Страница 30: ...5 screw 2 places Hex Nut 2 places Flat washer 2 places Spring washer 2 places Wire terminal lug 2 places Flat washer 2 places Screws tightening torque 290 310 Lb inch Output Load Wires No Conductor Pr...

Страница 31: ...n the shutter to secure load wires in place and tighten screws B Fig 3 10 Enclosure assembly Load wires Negative Output Return Positive output Shutters Enclosure bottom cover Enclosure top cover B A1...

Страница 32: ...inimize noise pick up If shielded wires are used the shield should be connected to the ground at one point either at the power supply chassis or the load ground The optimal point for the shield ground...

Страница 33: ...wires Each load should be separately connected to the remote distribution terminals see Fig 3 14 If remote sensing is required the sensing wires should be connected to the distribution terminals or a...

Страница 34: ...the maximum output voltage of the power supply Ensure that the connections at the load end are shielded to prevent accidental contact with hazardous voltages 3 10 2 Local sensing The power supply is s...

Страница 35: ...t the J2 mating connector is plugged securely into the rear panel sense connector J2 4 Turn On the power supply 1 If the power supply is operating in remote sense and either the positive or negative l...

Страница 36: ...4 3 Rear panel controls and connectors See Fig 4 1 to review the controls indicators and meters located on the power supply front panel TM 27 1 Number Control Indicator Description Section High resol...

Страница 37: ...play shows OUP Press again to set the UVLusing VOLTAGE encoder the current display shows UUL Main function Auxiliary function Go to local Press REM LOC to put the unit into Local REM LOC button is dis...

Страница 38: ...rear panel Refer to Table 4 2 for explanations about the rear panel connections and controls Fig 4 2 Rear panel connections and controls 1 Number Item Description Section AC input connector 2 DC outpu...

Страница 39: ...r RS232 485 mode when IEEE option is installed Number Item Description Section 4 5 Connector for making remote sensing connections to the load for regulation of the load voltage and compensation of lo...

Страница 40: ...31...

Страница 41: ...alent Manual Pistol grip tool Handle AMP P N 58074 1 Head AMP P N 58063 2 Before making any connection turn the AC On Off switch to the Off position and wait until the front panel display has turned O...

Страница 42: ...33...

Страница 43: ...oltage When the output is disabled press the PREV button and then rotate the VOLTAGE encoder knob The VOLTAGE meter will show the programmed output voltage for 5 seconds after the adjustment has been...

Страница 44: ...VOLTAGE encoder knob to adjust the OVP level The display will show OUP and the setting value for 5 seconds after the adjustment has been completed and then will return to it s previous state The minim...

Страница 45: ...ncel the Foldback protection The power supply output will be disabled and the VOLTAGE display will show OFF Press the OUTbutton to enable the power supply output 3 Turn the power supply output Off and...

Страница 46: ...n collector output with a 30V parallel zener at J1 13 referenced to the COM potential at J1 12 connected internally to the negative sense potential When the power supply operates in Constant Voltage m...

Страница 47: ...shows O7P and the ALARM LED blinks Resetting the OTP circuit can be automatic non latched or manual latched depending on the Safe orAutomatic restart mode In Safe start mode the power supply stays of...

Страница 48: ...of the units shuts down Each diode should be rated to at least the power supply rated output voltage and output current Refer to Fig 5 1 and 5 2 for series operation with local and remote sensing S S...

Страница 49: ...4 Programming via the Serial Communication port RS232 RS485 5 14 2 Series connection for positive and negative output voltage In this mode two units are configured as a positive and negative output S...

Страница 50: ...he number of parallel units During operation the master unit operates in CV mode regulating the load voltage at the programmed output voltage Connect the sensing circuit to local or remote sensing as...

Страница 51: ...tting change refer to Sec 7 2 7 for details b The Slave units parameters will automatically set the following Output voltage to approximate 102 of rated output voltage Programmed Current to zero UVL t...

Страница 52: ...J1 16 J1 15 PS_OK POWER SUPPLY 2 J1 2 3 J1 15 PS_OK SO POWER SUPPLY 3 J1 2 3 J1 15 PS_OK SO SO IF_COM IF_COM IF_COM 5 17 FRONT PANEL LOCKING The front panel controls can be locked to protect from acci...

Страница 53: ...tput voltage and current limit can be programmed via the front panel VOLTAGE and CURRENT encoders or via the RS232 485 port In Remote Analog mode the output voltage and current limit can be programmed...

Страница 54: ...SW1 2 to its UP position for Output Current limit external programming 3 Set SW1 position 3 to select programming voltage range according to Table 6 3 4 Ensure that SW1 positions 7 and 8 are at their...

Страница 55: ...resistors to the mating plug of J1 as shown in Fig 6 2 7 Set the programming resistors to the desired resistance and turn the power supply ON Adjust the resistors to change the power supply output 1 S...

Страница 56: ...nitor Iout monitor Vout monitor Iout monitor Signal J1 11 J1 24 J1 11 J1 24 J1 12 J1 12 0 5V 0 10V Down Up Range SW1 4 Return J1 connection Table 6 5 Monitoring signals setting FCC requirements for ra...

Страница 57: ...REM LOC button to put the unit into Local mode 2 Press and hold for approximately 3sec the REM LOC button The VOLTAGE display will indicate the communication port address 3 Using the VOLTAGE adjust e...

Страница 58: ...o set the status registers and read them while the unit is in Local mode If the Enable registers are set refer to section 7 8 the power supply will transmit SRQ s while in Local Front panel control in...

Страница 59: ...50...

Страница 60: ...bit The Address is sent separately from the command It is recommended to add a 100 msec software delay between query or sent command to next unit addressing Refer to section 7 7 3 for details The end...

Страница 61: ...s a numeric value the value may be up to 12 characters long 4 Carriage Return If the CR character ASCII 13 is received by itself the power supply will respond with OK and CR The Genesys 3300W series c...

Страница 62: ...7 5 Output control commands 7 7 4 ID control commands Command Description Returns the power supply model identification as an string Returns the software version as an ASCII string Returns the unit s...

Страница 63: ...ting level is shown in Table 5 1 Attempting to program the OVP below this level will result in execution error response E04 The OVP setting stays unchanged 15 OVP n Returns the power supply operation...

Страница 64: ...The conditional register FLT and STAT are updated Other registers are not changed Non Latching faults FB OVP SO are cleared OUT fault stays Sets the output voltage value in volts The range of voltage...

Страница 65: ...easured current PC programmed set current SR status register 2 digit hex FR fault register 2 digit hex Example response MV 45 201 PV 45 MC 4 3257 PC 10 SR 30 FR 00 Reads Fault Conditional Register Ret...

Страница 66: ...mand or query received One SRQ when SEVE goes from all zeroes to any bit set Setting more SEVE bits does not cause more SRQs Positive Logic 0 No Event 1 Event Occured 7 8 STATUS ERROR AND SRQ REGISTER...

Страница 67: ...own has occurred The supply output is turned On by front panel button or OUT 1 command The supply output is turned On by front panel button or OUT 1 command The supply output is turned On by front pan...

Страница 68: ...OFF ENA Bit Set condition Bit reset condition User command FENA nn where nn is hexadecimal User command FENA nn where nn is hexadecimal if nn 00 no fault SRQs will be generated Table 7 10 Fault Event...

Страница 69: ...ommand to read the register CLS and power up also clear the Status Event Register The Fault Event Register is not cleared by RST BIT Status name Status symbol Bit Set condition Bit reset condition Cha...

Страница 70: ...ds with line feed On some PC systems pressing the number keypad Enter will distort displayed messages Use the alphabetic Enter instead Bits per second 9600 Data bits 8 Parity None Stop bits 1 Flow con...

Страница 71: ...e programming temperature coefficient Output current programming temperature coefficient Input impedance Absolute maximum voltage Max voltage between program inputs and supply outputs Output voltage m...

Страница 72: ...ption Chassis ground Chassis ground SHLD 1 Output voltage programming input Output current programming input 2 IPROG_ISO 3 Ground for programming signals Ground for programming signals Output voltage...

Страница 73: ...he voltage source 8 Set the programming sources to the desired levels and turn the power supply ON Perform the following procedure to configure the power supply 1 Turn the power supplyAC power switch...

Страница 74: ...ade only by the manufacturer or by authorized service facilities no parts replacement information is provided in the manual In case of failure unusual or erratic operation of the unit contact a Lambda...

Страница 75: ...g equipment Check Foldback setting and load current Connect the sense wires according to User s manual instructions Turn Off the AC power and wait until the display turns off Turn on the AC power and...

Страница 76: ...ing power supplies line feed local operation local sensing lock front panel maintenance otp outline over voltage parallel operation parity ps_ok preview rack mounting rear panel remote sensing remote...

Страница 77: ...NOTES 68...

Страница 78: ...NOTES 69...

Страница 79: ...NOTES 70...

Страница 80: ...NOTES 71...

Страница 81: ...NOTES 72...

Страница 82: ...4 Menara Merais No 1 Jalan 19 3 Section 19 3 46300 Petaling Jaya Selangor Darul Ehsan Malaysia Tel 60 3 7957 8800 Fax 60 3 7958 2400 www tdk lambda com NORTH AMERICA TDK Lambda Americas Inc 405 Essex...

Отзывы: