Genery hagenuk Скачать руководство пользователя страница 21

38

39

Appendix

Tones

Acoustic signals when calling:

• You can hear the dialling tone when

you press the 

g

key

• The ringing tone is to be heard when

the number dialled is available.

• The engaged tone is to be heard when

the number dialled is unavailable (the
line is busy).

• The call-waiting tone during an inter-

nal call notifies you that an external
call is being received.

Acoustic signals when operating and
programming:

• The positive acknowledgement tone

confirms a correct entry.

• The negative acknowledgement tone

indicates that an error has been made.

6.3 Package Contents

1 Base station
1 Handset
1 Plug-in power supply
1 Telephone connecting cable
1 Shirt clip
1 Instruction manual (with card display-

ing accessories and further Hagenuk
CPS products)

6.4 Condition on Delivery

Your cordless Genery ISDN telephone has
the following factory settings:

Phonebook

No entry

Last number redial

No entry

Ringing tone melody

3 internal/
2 external

Ringing tone volume

5 internal/
5 external

Earphone volume

3 (medium)

Key tones

On

Battery warning

On

Illumination
when key is pressed

On

Incoming call

LED red on

Key lock

Off

Total lock

On

Battery type

Auto

Notebook

No entry

PIN

0 0 0 0

Call list

No entry

Anonymous

No

Phone number (MSN)

No entry

Local area code

No entry

Country

(depending on 
version)

Language

(depending on 
version)

Cost factor

No entry

Exchange code

No entry

Exch. code sent

On

Automatic end of
conversation

On

The supplied handset is registered on
base A as internal subscriber no. 1.

Standard:

Send / receive frequency:

Range:

Power supply:

Batteries:

Operating life
(with fully charged batteries, 
2 x 1200 mAh):

Charging time:
(with empty batteries 1200 mAh)

Recommended environmental
conditions:

Dimensions:

Base station
Handset

Weight:

Base station
Handset

Length of connecting cable:

Connecting plug: phone line

Power cable

Storage temperature:

DECT GAP

1880 – 1900 MHz

up to 300 m / 1000 ft
(in buildings up to 50 m)

base 230 V~ / 50 Hz, 11 VA
(SNG 010 W / SNG 10 WGB plug-in
power supply)

2 x NiCd / NiMH (2AA)
700 – 1200 mAh

in stand-by mode: up to 200 hrs. (typ.)
during call: up to 12 hrs. (typ.)

approx. 9 hrs.

+5° C to +40° C / 20% to 75% rel.
humidity

BxHxD = approx. 131 x 65 x 140 mm
BxHxD = approx. 58 x 160 x 33 mm

approx. 220 g
approx. 160 g (incl. batteries)

power cable for base station 2 m
telephone connecting cable 3 m

Western - Western (ISDN)

plug-in power supply with Euro mains
connector
Miniwestern RJ11 equipment side

0° C to +55° C

6.5 Technical Data

Ringing tone

Busy tone

Positive acknowledgement tone

Negative acknowledgement tone

Call waiting tone

(repeated)

(repeated)

0,5

0,6

0,2

0,2

0,6

0,2

0,2

0,5

0,6

0,5

0,5

0,5

0,5

0,5

0,5

0,5

0,3

0,3

0,3

0,3

0,3

0,3

0,3

0,3

0,3

0,3

3

3,5

0.1 each

4

1

1

Dial tone

Содержание hagenuk

Страница 1: ...GENERY ISDN DECT GAP T E C H N O L O G Y Operating Manual...

Страница 2: ...Key Lock 16 2 5 4 Telephoning with Blocking 16 3 Phone Number Memory 17 3 1 Call List 17 3 1 1 Displaying the Call List 17 3 1 2 Dialling from the Call List 17 3 1 3 Deleting Entries 17 3 2 Phonebook...

Страница 3: ...ing 22 4 3 2 Resetting the Counter 22 4 4 Blocking 23 4 4 1 Switching on 23 4 4 2 Switching off 23 4 5 Direct Call 23 4 5 1 Entering a Phone Number 23 4 5 2 Switching on 23 4 5 3 Switching off 23 4 6...

Страница 4: ...s regarding this please contact your network operator Safety Notes Use only the SNG 10 W SNG 10 WGB plug in power supply provi ded with your equipment When inserting the batteries make sure they are o...

Страница 5: ...essories on a non slip surface so that the plastic feet do not interact with the lacquer coating of the furni ture leaving unsightly marks on the surface The recommended environmental con ditions for...

Страница 6: ...ps see chapter 5 7 3 Finally you have to program your ISDN numbers MSNs see chapter 5 7 4 For operation with a private telecom munications switching system PABX see chapter 5 7 6 For operation with se...

Страница 7: ...n switch to this mode via the softkey DIAL Keypad YES NO The setting only applies to the next out going call dialled 2 1 1 Dialling after line seizure g key Enter a phone number If you wish to seize a...

Страница 8: ...ay internal number g key 2 1 3 Linking Phone Numbers If you are at the pre dialling stage you can combine and or manually change phone numbers from various sources The following example shows the link...

Страница 9: ...e same basic access and programmed to signal the call for the same MSN Accept will accept the waiting call and the existing internal call will be interrupted To terminate an internal call Display Call...

Страница 10: ...ame number will cause a negative acknowledgement signal to sound 2 4 Ending a Call g key After ending a call you have initiated the call time and if available the charges incurred will be shown on the...

Страница 11: ...PTION Menu item Entry modify The same options are available for chan ging entries as described under 3 2 2 3 2 5 Specifying Emergency Numbers Softkey LIST Submenu Phonebook Softkey OK Softkey OPTION M...

Страница 12: ...Softkey EDIT Enter change number as applicable Softkey EDIT Select Save Softkey YES Softkey ON or OFF key approx 2 secs 4 1 3 if no Radio Link key Submenu Call forwarding CF Softkey OK Menu item CF i...

Страница 13: ...Softkey ON or OFF key approx 2 secs Each phone number MSN is assigned to a ringing group At first all registered devices are included in all ringing groups so that they all can receive calls for each...

Страница 14: ...rogramming function will be abor ted and the PIN will not be changed 4 6 Babyphone You can use your handset as a babypho ne A room will then be continuously monitored by the microphone of the handset...

Страница 15: ...er increasing volume or to switch off the ringing tone completely with OFF Even if the ringing tone is switched off all calls will still be shown on the display You can also set optical signalling opt...

Страница 16: ...r automatic call answering Please bear in mind that if the illumina tion is switched on the operating life is shortened due to increased energy con sumption 5 2 2 Setting Earphone Volume Menu Settings...

Страница 17: ...l number in order to initiate a call in the public exchange This trunk code must always be dialled no matter if you dial manually or auto matically from the phonebook or call list So the system s trun...

Страница 18: ...on 5 11 Automatic End of Call Menu Settings Submenu Automatic call end Softkey ON If Automatic call end is activated your handset will switch off automatically after the other party has terminated the...

Страница 19: ...ble capacities choose the next higher setting or Auto The less you replace the handset on the base or a charging station after calls the more chance the system has of achieving optimum charging of the...

Страница 20: ...ed All characters to the right of it will shift to the left Inserting characters New characters can be inserted at the point where the cursor is flashing The character already in this position and tho...

Страница 21: ...Local area code No entry Country depending on version Language depending on version Cost factor No entry Exchange code No entry Exch code sent On Automatic end of conversation On The supplied handset...

Страница 22: ...Incorrect base selection Plug on connecting cord not properly inserted Ringing tone is switched off or set too low Trunk code not entered Remedy Press g Recharge handset or batte ries Insert batterie...

Страница 23: ...28 Volume 14 29 A Accessories 9 Acknowledgement tone 38 Appendix 35 Area code 31 Audio 27 Automatic call answering 13 Automatic Call Back 12 Automatic end of call 33 B Babyphone 24 Batteries inserting...

Страница 24: ...r edit Charge factror in Euro CF with Keypad Remote service Name enter Bat Capacity Auto 700 mAh 1200 mAh Base select Log in Automatic call end LIST CALL LIST PHONEBOOK Entry modify Entry new Entry de...

Страница 25: ...g manual Hagenuk CPS GmbH Genery ISDN Westring 431 Mat Nr 3301 141 D 24118 Kiel Edition 05 03 2001 This equipment satisfies the requirements set forth in the EU directive 1999 05 EG In evidence of thi...