background image

CONTENTS 

Certified for shock and electrical fire hazard only. 

SAFETY CONSIDERATIONS 

Read and follow instructions carefully. Follow all local 

electrical  codes  during  installation.  All  wiring  must 
conform  to  local  and  national  electrical  codes.  Improper 
wiring or installation may damage the Air Cleaner. 

Understand  the  signal  words  WARNING  and 

CAUTION which are present in the Installation, Operation 
& Service Instructions. 

WARNING  and  CAUTION  signifies  a  hazard  which 

could result in property damage, personal injury or death. 

Installation  and  servicing  of  Electronic  Air  Cleaners 
can be hazardous. Only trained and qualified service 
personnel should install, repair, or service Electronic 
Air Cleaners. 

Untrained 

personnel 

can 

perform 

the 

basic 

maintenance  functions  of  cleaning  and  replacing 
filters. 

When  working  on  air  cleaning  equipment,  observe 
precautions in the manual, labels attached to the unit, 
and  other  safety  precautions  that  may  apply.  Follow 
all  safety  codes.  Wear  safety  glasses  and  work 
gloves. 

 

WHAT THE ELECTRONIC AIR CLEANER DOES 

Your  High  Efficiency  Electronic  Air  Cleaner  has  been 

designed  to  remove  tobacco  smoke  particles,  cooking 
smoke  and  grease,  atmospheric  dust,  coal  dust, 
insecticide  dust,  mites,  pollen,  mold  spores,  fungi, 
bacteria,  viruses  and  more  down  to  0.01  micron  (0.01 
micron = 1/2,540,000 of an inch). 

BENEFITS 

Helps  clear  up  a  smokey  environment  quickly,  so 
customers can dine more comfortably. 
Helps employees reduce suffering from irritated eyes, 
nasal  congestion  and  respiratory  problems  that  lead 
to absenteeism. 
Helps  prevent  damaging  black  and  greasy  particles 
from staining ceilings, walls and furnishings, reducing 
the amount of housekeeping and redecorating costs. 
Helps to lower energy bills by recycling air rather than 
exhausting expensive heated or cooled air. 

HOW IT WORKS

 

This  Air  Cleaner  works  on  the  principle  of 

"Electrostatic Precipitation". Millions of airborne pollutants 
are drawn through the intake grill on the bottom of the Air 
Cleaner  and  first  pass  through  a  Prefilter  which  removes 
all  large  visible  particles  such  as  lint.  Next,  smaller 
particles move to a two-stage electrostatic Collecting Cell 
where  they  are  given  a  powerful  positive  charge  by  the 
ionizing  wires.  Charged  particles  then  move  into  the 
collecting  area  where  they  are  attracted  to  a  series  of 
grounded plates. Pollutants are held in this section like a 
magnet  until  washed  away  during  cleaning.  Clean  air  is 
then  dispersed  from  the  side  grills  in  four  directions 
allowing superior air flow circulation. 

 

IMPORTANT:

 Please read entire instructions before 

installing the Electronic Air Cleaner. 

WARNING  

Before  beginning  any  installation  or  modification,  be 
certain that the main line electrical disconnect switch is 
in 

OFF

  position.  Electric  shock  could  result.  Tag 

disconnect switch with suitable warning labels.  

SAFETY CONSIDERATIONS   

WHAT THE ELECTRONIC AIR CLEANER DOES 

BENEFITS 

HOW IT WORKS  

MAJOR COMPONENTS  

INSTALLATION 

3-4 

Mounting  

Wiring  

OPERATION & MAINTENANCE 

Operation Check  

Maintenance Schedule  

Cleaning 

SERVICE  

5-7 

Testing For High Voltage At Power Board 

Measuring High Voltage At Power Board 

Replacing A Performance Light 

Replacing A Power Board 

Testing The 24 V Transformer 

Replacing The 24 V Transformer 

Setting Voltage Of Power Board 

Setting Approximate Voltage Without High Voltage Meter 

Testing For Voltage at The Cell 

Testing Cell For Bad Contacts 

Testing Cell With An Ohmmeter 

Replacing A Tungsten Wire 

Replacing A Fan Motor 

REMOTE SWITCH CONTROL 

Electrical Schematic 

TROUBLESHOOTING GUIDE 

Exploded View  

10 

Parts List 

10 

Technical Data and Dimensions 

11 

WARRANTY  

12 

Fig. 1 

 Electrostatic Precipitation 

1 Dirty Air 

 

 

 

 

2 Prefilter 

 

 

3 Charging  

Section 

 
4 Collecting Cell 
Plates 
 

 
 

5 Clean Air 

 

Содержание SSCB-15 SERIES

Страница 1: ...Operation And Maintenance Manual SSCB 15 SERIES CEILING MOUNTED ELECTRONIC AIR CLEANER IMPORTANT PLEASE READ MANUAL BEFORE INSTALLING OPERATING CLEANING OR SERVICING UNIT ...

Страница 2: ...led air HOW IT WORKS This Air Cleaner works on the principle of Electrostatic Precipitation Millions of airborne pollutants are drawn through the intake grill on the bottom of the Air Cleaner and first pass through a Prefilter which removes all large visible particles such as lint Next smaller particles move to a two stage electrostatic Collecting Cell where they are given a powerful positive char...

Страница 3: ...nstallation should be done by a knowledgeable technician 4 After installation check out operation as provided in these instructions Mounting 1 Remove the unit from the box with packing still on the unit and lay it on its back grill side up 2 Release the cover by sliding towards the front of the unit and lifting up 3 Remove the S hook from each chain tilt cover up and release from back 4 Remove the...

Страница 4: ... checked on a regular basis to determine the frequency of cleaning required in each location and a cleaning schedule established Cleaning 1 Turn off the system switch and wait 15 seconds for high voltage to dissipate 2 Open the cover and cell access door and remove collecting cells and prefilters Cell plates are sharp Handle with care 3 Place cells in tub and spray completely with DAX Detergent al...

Страница 5: ...ved check the power board system switch and transformer to make sure that they are functioning correctly 6 If there is voltage present but the performance light does not come on replace the light 7 High voltage can be adjusted with the high voltage potentiometer if required Replacing A Performance Light Before replacing the performance light turn OFF power to the Air Cleaner at the source 1 Lower ...

Страница 6: ...tting Voltage Of Power Board Voltage on the power board may drop below required level when the installation area is too damp too cold or the input power to the unit is low Voltage on power board may be too high when the installation area is too dry or too hot or the input power to the unit is high By adjusting the HV Adj potentiometer the voltage can be set to optimum level A high voltage meter ca...

Страница 7: ...t the bottom of the cell 5 Using needle nose pliers grip the other end of wire near the bottom of the top loop Pull the wire up toward the top finger As you apply tension the bottom finger will give allowing the placement of the loop around the top finger 6 Install cell in Air Cleaner 7 Return power to Air Cleaner 8 Test cell for proper operation Replacing A Fan Motor 1 Turn OFF power to Air Clean...

Страница 8: ...Fig 6 Electrical Schematic With Wired Remote 120 Volt Fig 5 Electrical Schematic 120 Volt 8 ...

Страница 9: ...e indicator light is ON Defective power switch Check power switch for continuity with ohmmeter Replace if defective Defective speed selector switch Check switch for continuity with ohmmeter Replace if defective Defective fan motor Test motor and replace if defective Cell makes loud hissing noise or causes radio interference Internal cell contacts are not touching plates Test contacts and repair Hi...

Страница 10: ...CCM13 06G 7 Collecting Cell EACCM13 07 8 Cell Handle EAC14 16 9 Ionizing Wire EAC20 19 10 Safety Interlock Switch EACCM13 10 11 Red Indicator Light EACCM13 11 12 Power Switch Gray EACCM13 12W Description Part Number 12a Power Switch Black EACCM13 12G 13 3 Position Slide Switch Gray EACCM13 13W 13a 3 Position Slide Switch Black EACCM13 13G 14 Power Board Fibreboard EACCM13 14 15 Power Board EACCM13...

Страница 11: ... in 68 6 cm Height 14 5 in 37 0 cm Weight 95 0 lbs 43 0 kg Input Voltage 120 V 60 Hz Power Consumption max 350 Watts Air Flow High 1300 CFM 2210 m3 hr Medium 1050 CFM 1785 m3 hr Low 750 CFM 1275 m3 hr Motor 1 12 HP Table 2 Technical Data Fig 8 Dimensions ...

Страница 12: ...to General Filters Inc THERE ARE NOT EXPRESS WARRANTIES COVERING THIS ELECTRONIC AIR CLEANER OTHER THAN AS SET FORTH ABOVE THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY EXCLUDED THE MANUFACTURER ASSUMES NO LIABILITY IN CONNECTION WITH THE INSTALLATION OR USE OF THIS PRODUCT EXCEPT AS STATED IN THE LIMITED WARRANTY THE MANUFACTURER WILL IN NO EVENT BE ...