MAJOR COMPONENTS 

Description 

The Electronic Air Cleaner is approximately 29½ x 27 

x 14½ inches (75 x 68.6 x 37 cm). The unit is designed to 
be mounted to the ceiling. The steel cover and intake grill 
are  hinged  to  allow  easy  access  to  the  collecting  cells 
and  power  box.  The  unit  is  rated  up  to 1300  CFM  (2210 
m

3

/hr). 

Cabinet 

The  cabinet  is  constructed  of  20  gauge  steel.  The 

external  parts  have  a  tough  powder-coated,  scratch-
resistant  finish.  The  internal  parts  are  galvanized  steel. 
Access to the collecting cells, power box and prefilters is 
made  by  lifting  the  cover,  sliding  towards  the  front  and 
lowering. 

The cover is interlocked to cut power to the unit when 

opened. 

Prefilters

 

The  washable  prefilters  measuring  12½  x  20  inches 

(31.75  x  50.8  cm)  are  constructed  of  multi-layers  of 
aluminum mesh for maximum filtration of large particles. 

Collecting Cells

 

The  dual  voltage  collecting  cells  are  constructed  of 

heavy  gauge  aluminum  to  resist  rust  and  damage.  The 
first  stage,  the  ionizing  section,  is  charged  at 

approximately  7500  VDC.  The  collecting  plates  are 
alternately  grounded  and  charged  at  5000  VDC.  The 
arrow  on  the  cell  indicates  the  direction  of  air  flow  which 
must point up towards the fan motor. 

Motor & Fan Blade

 

The motor is 1/12 HP, 1050 RPM, 3 speed, controlled 

by  a  3-position  slide  switch.  The  motor  is  thermally 
protected.  The  fan  blade  is  aluminum,  18  inches  (45.7 
cm) with a 16

˚ pitch.

 

 

INSTALLATION 

1.  Read  instructions  carefully.  Failure  to  do  so  may 

result in product damage or injury. 

2.  Make sure the sizing is correct for your application. 

3.  Installation  should  be  done  by  a  knowledgeable 

technician. 

4.  After  installation,  check  out  operation  as  provided  in 

these instructions. 

Mounting 

1.  Remove the unit from the box with packing still on the 

unit and lay it on its back, grill side up. 

2.  Release the cover by sliding towards the front of the 

unit and lifting up. 

3.  Remove  the  "S"  hook  from  each  chain,  tilt  cover  up, 

and release from back. 

4.  Remove  the  cells  and  prefilters  from  the  unit  before 

installing. 

5.  Holes  are  provided  in  the  cabinet  to  accommodate 

5/16 inch (8 mm) threaded rod. Threaded rod can be 
attached  to  angle  iron,  laid  across  the  joists,  and 
drilling  holes  through  these  supports.  Pass  threaded 
rod up through the supports and secure with two nuts 
and washers. This will allow adjustment of the unit so 
that it is flush with the underside of the ceiling. 

 

Leave  enough  room  around  the  Air  Cleaner  for 
removal of collecting cells and prefilters.

 

6.  Replace  the  cells,  prefilters  and  cover.  Hook  up  the 

safety chain to the cover. 

Do not hang the unit with chain only. This will not 

Fig. 2 

 Coanda Air Flow 

The 

Air 

Cleaner 

creates  a  circular  air 
flow 

pattern 

which 

never  allows  air  to 
rest at the ceiling. 

 

Blower 

and 

Motor 

are 

hidden  behind  4  directional 
discharge air grills. 
 
 
 
Rear  Hinge  permit  smooth 
release  of  cover  for  easy 
installation. 
 
 
3-Speed  Fan  Control  allows 
adjustment  of  air  flow  to 
activity level in room. 
 
 
Hinged 

Cover 

provides 

convenient  access  to  Grill, 
Prefilters 

and 

Collecting 

Cells.  Safety  interlock  cuts 
power 

when 

cover 

is 

opened. 

Heavy  duty  Collecting  Cells 
( 2 )  

c a p t u r e  

a i r b o r n e 

pollutants  and  simply  wash 
clean. 
 
 
 
 
Washable,  aluminum  mesh 
Prefilters  (2)  catch  lint  and 
large  particles  before  they 
enter collecting cells. 
 
 
 
 
Removable  Intake  Grill  for 
easy cleaning. 
 

Fig. 3 

 Components 

Содержание SSCB-15 SERIES

Страница 1: ...Operation And Maintenance Manual SSCB 15 SERIES CEILING MOUNTED ELECTRONIC AIR CLEANER IMPORTANT PLEASE READ MANUAL BEFORE INSTALLING OPERATING CLEANING OR SERVICING UNIT ...

Страница 2: ...led air HOW IT WORKS This Air Cleaner works on the principle of Electrostatic Precipitation Millions of airborne pollutants are drawn through the intake grill on the bottom of the Air Cleaner and first pass through a Prefilter which removes all large visible particles such as lint Next smaller particles move to a two stage electrostatic Collecting Cell where they are given a powerful positive char...

Страница 3: ...nstallation should be done by a knowledgeable technician 4 After installation check out operation as provided in these instructions Mounting 1 Remove the unit from the box with packing still on the unit and lay it on its back grill side up 2 Release the cover by sliding towards the front of the unit and lifting up 3 Remove the S hook from each chain tilt cover up and release from back 4 Remove the...

Страница 4: ... checked on a regular basis to determine the frequency of cleaning required in each location and a cleaning schedule established Cleaning 1 Turn off the system switch and wait 15 seconds for high voltage to dissipate 2 Open the cover and cell access door and remove collecting cells and prefilters Cell plates are sharp Handle with care 3 Place cells in tub and spray completely with DAX Detergent al...

Страница 5: ...ved check the power board system switch and transformer to make sure that they are functioning correctly 6 If there is voltage present but the performance light does not come on replace the light 7 High voltage can be adjusted with the high voltage potentiometer if required Replacing A Performance Light Before replacing the performance light turn OFF power to the Air Cleaner at the source 1 Lower ...

Страница 6: ...tting Voltage Of Power Board Voltage on the power board may drop below required level when the installation area is too damp too cold or the input power to the unit is low Voltage on power board may be too high when the installation area is too dry or too hot or the input power to the unit is high By adjusting the HV Adj potentiometer the voltage can be set to optimum level A high voltage meter ca...

Страница 7: ...t the bottom of the cell 5 Using needle nose pliers grip the other end of wire near the bottom of the top loop Pull the wire up toward the top finger As you apply tension the bottom finger will give allowing the placement of the loop around the top finger 6 Install cell in Air Cleaner 7 Return power to Air Cleaner 8 Test cell for proper operation Replacing A Fan Motor 1 Turn OFF power to Air Clean...

Страница 8: ...Fig 6 Electrical Schematic With Wired Remote 120 Volt Fig 5 Electrical Schematic 120 Volt 8 ...

Страница 9: ...e indicator light is ON Defective power switch Check power switch for continuity with ohmmeter Replace if defective Defective speed selector switch Check switch for continuity with ohmmeter Replace if defective Defective fan motor Test motor and replace if defective Cell makes loud hissing noise or causes radio interference Internal cell contacts are not touching plates Test contacts and repair Hi...

Страница 10: ...CCM13 06G 7 Collecting Cell EACCM13 07 8 Cell Handle EAC14 16 9 Ionizing Wire EAC20 19 10 Safety Interlock Switch EACCM13 10 11 Red Indicator Light EACCM13 11 12 Power Switch Gray EACCM13 12W Description Part Number 12a Power Switch Black EACCM13 12G 13 3 Position Slide Switch Gray EACCM13 13W 13a 3 Position Slide Switch Black EACCM13 13G 14 Power Board Fibreboard EACCM13 14 15 Power Board EACCM13...

Страница 11: ... in 68 6 cm Height 14 5 in 37 0 cm Weight 95 0 lbs 43 0 kg Input Voltage 120 V 60 Hz Power Consumption max 350 Watts Air Flow High 1300 CFM 2210 m3 hr Medium 1050 CFM 1785 m3 hr Low 750 CFM 1275 m3 hr Motor 1 12 HP Table 2 Technical Data Fig 8 Dimensions ...

Страница 12: ...to General Filters Inc THERE ARE NOT EXPRESS WARRANTIES COVERING THIS ELECTRONIC AIR CLEANER OTHER THAN AS SET FORTH ABOVE THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY EXCLUDED THE MANUFACTURER ASSUMES NO LIABILITY IN CONNECTION WITH THE INSTALLATION OR USE OF THIS PRODUCT EXCEPT AS STATED IN THE LIMITED WARRANTY THE MANUFACTURER WILL IN NO EVENT BE ...