background image

eaccm13-2a.pub 

08/10 

14483A

 

ELECTRONIC AIR CLEANER 

LIMITED ONE YEAR WARRANTY 

 

Electronic Air Cleaners, if properly registered by the return of the attached warranty registration to 
General Filters, Inc., are warranted to the consumer against defects in materials and workmanship 
for a period of one year from the date of installation, so long as the product has been installed and 
operated  in  accordance  with  all  appropriate  manuals  and  wiring  diagrams.  Replacement  or 
routinely replaceable parts such as prefilters, are not covered by this limited warranty or any other 
warranties.  Any  other  defective  parts  will  be  repaired  without  charge  except  for  removal, 
reinstallation  and  transportation  costs.  To  obtain  repair  service  under  this  limited  warranty,  the 
consumer must send the defective part to General Filters, Inc. 
 
THERE  ARE  NOT  EXPRESS  WARRANTIES  COVERING  THIS  ELECTRONIC  AIR  CLEANER 
OTHER THAN AS SET FORTH ABOVE. THE IMPLIED WARRANTIES OF MERCHANTABILITY 
AND  FITNESS  FOR  A  PARTICULAR  PURPOSE  ARE  EXPRESSLY  EXCLUDED.  THE 
MANUFACTURER  ASSUMES  NO  LIABILITY  IN  CONNECTION WITH  THE  INSTALLATION  OR 
USE  OF  THIS  PRODUCT,  EXCEPT  AS  STATED  IN  THE  LIMITED  WARRANTY.  THE 
MANUFACTURER  WILL  IN  NO  EVENT  BE  LIABLE  FOR  INCIDENTAL  OR  CONSEQUENTIAL 
DAMAGES. 
 
This limited warranty gives you specific legal rights, and you may also have other rights which vary 
from state to state. Some states do not allow either limitations on implied warranties, or exclusions 
from incidental or consequential damages, so the above exclusion and limitation may not apply to 
you. 
 
Any  questions  pertaining  to  this  limited  warranty  should  be  addressed  to  General  Filters,  Inc. 
General Filters, Inc. has elected not to make available the informal dispute settlement mechanism 
which is specified in the Magnuson-Moss Warranty Act. 

Содержание SSCB-15 SERIES

Страница 1: ...Operation And Maintenance Manual SSCB 15 SERIES CEILING MOUNTED ELECTRONIC AIR CLEANER IMPORTANT PLEASE READ MANUAL BEFORE INSTALLING OPERATING CLEANING OR SERVICING UNIT ...

Страница 2: ...led air HOW IT WORKS This Air Cleaner works on the principle of Electrostatic Precipitation Millions of airborne pollutants are drawn through the intake grill on the bottom of the Air Cleaner and first pass through a Prefilter which removes all large visible particles such as lint Next smaller particles move to a two stage electrostatic Collecting Cell where they are given a powerful positive char...

Страница 3: ...nstallation should be done by a knowledgeable technician 4 After installation check out operation as provided in these instructions Mounting 1 Remove the unit from the box with packing still on the unit and lay it on its back grill side up 2 Release the cover by sliding towards the front of the unit and lifting up 3 Remove the S hook from each chain tilt cover up and release from back 4 Remove the...

Страница 4: ... checked on a regular basis to determine the frequency of cleaning required in each location and a cleaning schedule established Cleaning 1 Turn off the system switch and wait 15 seconds for high voltage to dissipate 2 Open the cover and cell access door and remove collecting cells and prefilters Cell plates are sharp Handle with care 3 Place cells in tub and spray completely with DAX Detergent al...

Страница 5: ...ved check the power board system switch and transformer to make sure that they are functioning correctly 6 If there is voltage present but the performance light does not come on replace the light 7 High voltage can be adjusted with the high voltage potentiometer if required Replacing A Performance Light Before replacing the performance light turn OFF power to the Air Cleaner at the source 1 Lower ...

Страница 6: ...tting Voltage Of Power Board Voltage on the power board may drop below required level when the installation area is too damp too cold or the input power to the unit is low Voltage on power board may be too high when the installation area is too dry or too hot or the input power to the unit is high By adjusting the HV Adj potentiometer the voltage can be set to optimum level A high voltage meter ca...

Страница 7: ...t the bottom of the cell 5 Using needle nose pliers grip the other end of wire near the bottom of the top loop Pull the wire up toward the top finger As you apply tension the bottom finger will give allowing the placement of the loop around the top finger 6 Install cell in Air Cleaner 7 Return power to Air Cleaner 8 Test cell for proper operation Replacing A Fan Motor 1 Turn OFF power to Air Clean...

Страница 8: ...Fig 6 Electrical Schematic With Wired Remote 120 Volt Fig 5 Electrical Schematic 120 Volt 8 ...

Страница 9: ...e indicator light is ON Defective power switch Check power switch for continuity with ohmmeter Replace if defective Defective speed selector switch Check switch for continuity with ohmmeter Replace if defective Defective fan motor Test motor and replace if defective Cell makes loud hissing noise or causes radio interference Internal cell contacts are not touching plates Test contacts and repair Hi...

Страница 10: ...CCM13 06G 7 Collecting Cell EACCM13 07 8 Cell Handle EAC14 16 9 Ionizing Wire EAC20 19 10 Safety Interlock Switch EACCM13 10 11 Red Indicator Light EACCM13 11 12 Power Switch Gray EACCM13 12W Description Part Number 12a Power Switch Black EACCM13 12G 13 3 Position Slide Switch Gray EACCM13 13W 13a 3 Position Slide Switch Black EACCM13 13G 14 Power Board Fibreboard EACCM13 14 15 Power Board EACCM13...

Страница 11: ... in 68 6 cm Height 14 5 in 37 0 cm Weight 95 0 lbs 43 0 kg Input Voltage 120 V 60 Hz Power Consumption max 350 Watts Air Flow High 1300 CFM 2210 m3 hr Medium 1050 CFM 1785 m3 hr Low 750 CFM 1275 m3 hr Motor 1 12 HP Table 2 Technical Data Fig 8 Dimensions ...

Страница 12: ...to General Filters Inc THERE ARE NOT EXPRESS WARRANTIES COVERING THIS ELECTRONIC AIR CLEANER OTHER THAN AS SET FORTH ABOVE THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY EXCLUDED THE MANUFACTURER ASSUMES NO LIABILITY IN CONNECTION WITH THE INSTALLATION OR USE OF THIS PRODUCT EXCEPT AS STATED IN THE LIMITED WARRANTY THE MANUFACTURER WILL IN NO EVENT BE ...