Page 13
9.7 Filtering
On the pump suction line, install one filter as indicated in fig. 6 and fig.6/a.
With a manually activated control valve
With pneumatic control valve
The filter must be installed as close as possible to the pump, should allow easy inspection and have the following
characteristics:
1. Minimum capacity 3 times greater than the pump’s rated flow value.
2. Filter port diameters must not be smaller than the pump inlet ports.
3. Filtration degree ranging between 200 and 360 µm.