Checkweigher user’s manual
27
“
Decimal places
”
Decimal places of the system.
“
OI DTM time
”
Photoelectronic switch input determination time. When the photoelectric switch
sense the item for time longer than this value, it takes that there is one item pass the
photoelectric switch. Its unit is ms.
“
Stable range
”,
“
Stable time
”
When the system weight change in a small range in certain time
,
the system
consider the weight is stable, the range is stable range and the time is stable time.
“
Time
”
Set system time in accordance with local time.
Fig 6-24 System parameter 2
“
ZT range
”,
“
ZT time
”
Zero-tracking range and zero-tracking time. When the system weight change in a
small range in certain time
,
the system will zero automatically, the range is
zero-tracking range, and the time is zero-tracking time.
“
Rejector
”
If the checkweigher need to use rejector, choose ‘yes’ and there will be rejector
parameter (product parameter 3) in Product parameter. If it needn’t to use rejector,
choose ‘no’ and the rejector parameter will not appear in product parameter.
“
Reset
”
This is used to initialize all the parameter, please don’t try to use this function
unless under guidance.
“
Rejector
”
If it need to conduct dynamic study, choose ‘yes’ and there will be dynamic study
interface (product parameter 4) in Product parameter. If it needn’t to, choose ‘no’ and
the rejector parameter will not appear in product parameter.
<
Savebest
> and <
Rebest
>
These two keys are used together. When you change the system parameters and