• All bearings are sealed and permanently lubricated. No further lubrication is needed.
• Periodically inspect all hardware, fittings and fasteners that may have loosened due to vibration - re-tighten as
needed.
• To minimize airborne dust particles periodically inspect all dust collection fittings - re-tighten as needed.
• Keep the outside of the unit clean and wipe off excessive dust or dirt with a dry rag.
• Clean filters
(bags on 10-510 or canisters on 10-510CF)
on a regular basis and replace as needed.
• Periodically inspect inside of all pipes, fittings, hoses, blast gates, and connectors for accumulated dust build-
up or other obstructions and clean as needed. Remove sections and vacuum or manually remove debris as
needed.
• Check and if necessary replace all damaged parts or components.
• Do not operate with a damaged filter bag or cartridge - replace a damaged filter immediately.
• Periodically inspect the power cord and plug for damage. If necessary replace the power cord and the POWER
RECEPTACLE at the first signs of visible damage.
• Use only recommended parts and accessories. The use of parts or accessories
NOT
recommended by
GENERAL® INTERNATIONAL
may result in a risk of injury or damage to the machine.
Turn the switch to the “OFF” position and unplug the unit from the power source before cleaning or
replacing filter bags or before performing any maintenance
Tip/Hint: To avoid potentially costly down-time, consider keeping a spare filter bag on-hand and nearby for use if
needed.
After a period of time depending on the frequency of use, the filter bags may become clogged and affect airflow
as well the overall efficiency of the unit. Should you notice a drop in the efficiency or performance of the unit, it
may be a sign that it is time to clean the filters bags. If so, proceed as follows:
1. Turn off and unplug the machine.
2. Unclip the belt clamp and remove the bag from the machine.
3. Clean the dust from inside the filter bag using a vacuum.
4. For extreme cases, after the initial cleaning with a vacuum, turn filter bag inside out and vacuum a second time,
laying the bag on flat hard surface (such as a table or workbench) and slowly passing the vacuum nozzle over
the entire surface area.
5. Re-install the bag and re-attach the clamp.
Note: Filter bags can also be machined washed (gentle cycle only) in cold or warm water. (Do not use hot water)
Do not use detergent. Make sure the bag has completely dried before re-installing on the machine.
For machine washing, make sure to remove the belt clamp from the bag before washing!
CLEANING OR REPLACING THE FILTER BAGS (10-510 only):
14