21
Form No. 5500-32 Rev C
Code: +0700092EN REV 3.2 04APR2022
ENG
During the cleaning, the electrodes are powered and water
in the cylinder rises until it touches the high-level sensor or
reaches the high current limit; whichever comes first. After
either of the events is detected, the cylinder is fully discharged
with the electrodes un-powered (the drain pump and the drain
tempering valve are activated for 3 minutes). It is recommended
that two cleanings are performed when starting a new steam
unit. After the cleaning ends, the humidifier begins its regular
function. When starting the unit with a new or empty cylinder,
it may take a significant amount of time (hours) for the unit
to build up enough mineral concentration to reach rated
capacity. This time can be shortened by the addition of a
teaspoon of salt or ¼ of an antacid tablet through the steam
outlet on top of the cylinder.
Resetting the cylinder hour counter:
1. Switch the unit off. While pressing and holding both the
“RESET/SEL”
and
“DRAIN/ENT”
buttons, then switch the
unit on. Continue to hold both buttons until the wrench
symbol starts to blink, and then release both buttons.
2. Press and hold the
“RESET/SEL”
button until the value is
03 as shown on the display.
3. Press “drain” for a minimum of 1 second to confirm. The
hour counter will be reset once the unit resumes normal
operation.
Содержание GeneralAire 5500
Страница 6: ...6...
Страница 37: ...31 Form No 5500 32 Rev C Code 0700092EN REV 3 2 04APR2022 ENG...
Страница 38: ...32 NOTES...
Страница 39: ...33 Form No 5500 32 Rev C Code 0700092EN REV 3 2 04APR2022 ENG...
Страница 41: ...35 Form No 5500 32 Rev C Code 0700092EN REV 3 2 04APR2022 ENG...
Страница 42: ...36...
Страница 43: ...37 Form No 5500 32 Rev C Code 0700092EN REV 3 2 04APR2022 ENG Mode d emploi...
Страница 48: ...42...
Страница 79: ...31 Formulaire no 5500 32 Rev C Code 0700092EN REV 3 2 04APR2022 FRE...
Страница 81: ...33 Formulaire no 5500 32 Rev C Code 0700092EN REV 3 2 04APR2022 FRE NOTES...