background image

If unable to locate a dealer, cartridges and other parts may be ordered by mailing this form, or fax to our 24 hour fax order line 
(610) 363-0412 (Please include a daytime phone number.) You may also call 1-800-441-8166 between 8:00 AM - 4:30 PM ET. 
Please supply the information requested below. No P.O. Boxes, please. U.P.S. shipping charges and state taxes will be 
added where applicable.

Order Form

Name: ________________________________________

Address: ______________________________________

City: __________________________________________

State: _______________________  Zip: __________

Phone: ( ______ ) _______________________________ 

Please Print

(Circle One)
Charge my:  VISA        MasterCard        American Express 

  Part No. 

Item 

   Quantity

Send To:

General Ecology, Inc.

151 Sheree Blvd.

Exton, PA 19341 U.S.A.

www.generalecology.com

Expiration Date                

 

 

    Signature

Visit our web site and order online at www.generalecology.com

must be filled in

Beware of imitators’ cartridges that make claims to be as good as the RS-1SG purification 

cartridge. Use only genuine RS-1SG purification cartridges, manufactured by General 

Ecology, Inc. for the highest level of protection against waterborne disease. 

Cartridge Replacement Instructions

All Seagull

®

 IV X-1 units employ a RS-1SG Cartridge. The rated average capacity for the RS-1SG 

Cartridge is 1,000 gallons. Actual capacity will vary depending on operating conditions and the quality 

of the water source. Cartridges should be replaced when the flow rate decreases or when foul tastes or 

odors become apparent, or annually otherwise. Installing a Cartridge is easily accomplished as follows:

A.  Close cold water supply valve. 

 

B.  Open Faucet, and keep it open until new 

Cartridge is installed and operating. 

 

C.  Remove unit from Mounting Bracket, 

place over a large sauce pan or other 
container, remove V-Clamp and drain 
loose water from Pressure Vessel.  (If 
Pressure Vessel halves remain attached 
due to “set,” pull apart manually or 
momentarily allow a small amount of 
water to flow into the unit with the faucet 
closed to separate the halves. If faucet 
is closed, be sure and reopen before 
continuing with next step). 

 

D.  Remove expended Cartridge by placing 

plastic bag over it and turning counter 
clockwise. Close bag and discard. Rinse 
inside of Pressure Vessel with water and 
wipe clean with paper towel. Be sure thick 

Rubber Cartridge Seal is bonded in place 
inside the top of the unit.  

 

E.  Align carefully, and being careful not to 

cross thread, thread new Cartridge into 
place 

UNTIL CONTACT IS FIRST MADE 

WITH DARK BLUE CARTRIDGE GASKET, 
THEN TIGHTEN ONE QUARTER TURN 
ONLY. DO NOT OVERTIGHTEN.
 Please 
refer to Step 2 and Figure 2.  

  Reassemble the two stainless steel 

halves together, making sure the dark 
blue Housing Gasket is in place between 
the two halves. 

IMPORTANT: Make sure 

Gasket is not cut or nicked, and be sure 
housing has not been dropped or dented 
on either of the two mating halves. 

 

F.  Refer to Step 11 to place unit back in 

service. 

H

elpful

 H

ints

If you have difficulty separating the upper and 
lower halves of the pressure vessel, water 
pressure can help. Turn off cold water supply; 
remove the V-clamp and close the pure water 
faucet. With a pan ready to catch water from the 
unit, 

slowly turn on the water supply. Once the 

unit begins to separate, turn off the water supply 
and proceed according to your 

Installation and 

Operations instructions.

You may apply a light coating of petroleum jelly 
to the housing gasket to assure ease of opening 
and closing of the system.

When a new cartridge is put into service, you 
may see air bubbles and black particles in the 
water until the system has stabilized. These are 
harmless and will be purged from the system 
within the first few gallons of water.

General Ecology, Inc. — 6

Содержание SEAGULL IV X-1F

Страница 1: ...ossibility municipal water supplies install a Pressure Regulator or Surge Protector on the cold water supply line This system is intended to be installed to the cold water supply line downstream of an...

Страница 2: ...tion Cartridge 1 788000 5 X 1 Pressure Vessel 1 N A 6 Gasket Housing Dark Blue 1 710540 7 V Clamp for Housing 1 710534 No Description Qty Part No 8 Wing Nut for V Clamp 1 710032 9 Faucet FP threaded 1...

Страница 3: ...h 1 700060 3 screws RV Marine No Description Qty Part No 4 1 3 2 No Description Qty Part No 5 Gasket Housing Dark Blue 1 710540 6 V Clamp for Housing 1 710534 7 Wing Nut for V Clamp 1 710032 8 Gasket...

Страница 4: ...a d pilot hole upward a hole and then a g hole and finally the hole necessary to mount the faucet For man made and stone products consult counter top manufacturer s guidelines For stainless steel sin...

Страница 5: ...the first few days you may see entrapped air bubbles within the water This is perfectly normal and will cease after the unit has processed several gallons of water Also some black fines from inside of...

Страница 6: ...a large sauce pan or other container remove V Clamp and drain loose water from Pressure Vessel If Pressure Vessel halves remain attached due to set pull apart manually or momentarily allow a small am...

Страница 7: ...ble acting pump for more water with less work Field serviceable pump disassembles for easy cleaning and permits the X 1P water purifier to be used with gravity feed assistance systems Quick Disconnect...

Страница 8: ...mount of a non abrasive liquid detergent and a soft wet cloth Gently rub the soiled surface until the dirt is removed Then rinse clean and wipe with a dry soft cloth to remove water drops and to preve...

Отзывы: