Read instructions completely
before starting.
Follow steps
1 through 11 for system
installation. Steps
A through F on page 6 are
the RS-1SG purification cartridge replacement
instructions. An order form is included for
assistance in obtaining replacement RS-1SG
purification cartridges, and system parts.
Configuration dimensions are shown on page
8 at the end of this guide.
supersedes 200712D
General Ecology, Inc.
Seagull IV X-1F and Seagull IV X-1B drinking
water purification systems are designed
to operate at pressures ranging from 25 to
125 psi. If pressure surges are a possibility
(municipal water supplies), install a Pressure
Regulator or Surge Protector on the cold
water supply line. This system is intended
to be installed to the cold water supply line,
downstream of and above the cold water
shut-off valve inside the kitchen sink cabinet.
(see illustration on pages 2 and 3)
Be sure to close water supply valves before
installation. The Connector Hose will fit an
Owner Supplied Connector T or optional
stainless steel Compression T (part number
714358) shown on page 2. Connector branch
of
Owner Supplied Connector T must have
a
” male Compression thread (
h
” - 24
thread). The cold water supply line should be
clean and free of construction debris. A
p
” to
1
½
” diameter hole is necessary for mounting
the easily installed FP Faucet furnished with
this unit.