6.  Mount Faucet. Slide open side of Faucet 

Mounting Nut onto reduced diameter (Fig. 
5), un-threaded section of Faucet Stem 
now beneath the sink, and slide the Nut 
upwards to contact the threads. Then 
carefully engage the threads, being careful 
to not cross thread.  Hand tighten as 
necessary to hold the Faucet in place, but

 

do not use tools and do not overtighten. 
Check alignment and position of Faucet, 
and adjust as necessary. (We suggest 
you practice threading the Nut to the 
Stem above the sink, prior to the actual 
installation, to become familiar with the 
method before installing Faucet to sink.)

7.  Connect Inlet and Outlet lines. Connect 

free end of Thermoplastic Connection 
Hose from Faucet Stem to Outlet (center) 
Port on the Pressure Vessel. Tighten 
securely. 

Do not overtighten. Connect 

remaining Hose from fitting on cold water 
supply line to Inlet (outside) Port on top 
of Pressure Vessel. 

Do not overtighten.     

9.  Mount unit on the Residential Bracket 

by placing the V-Clamp over the raised 
section on top of the Bracket (Fig. 9). 

10. Mount unit on the Clip Bracket as shown 

(Fig. 10). A cotter pin or other pin, or wire 
can be inserted in the bracket, above the 
V-clamp to lock in place (see arrow) after 
unit is completely on the bracket.

11. 

Open the X-1F Faucet to allow air to 
exhaust slowly. Open Valve on cold water 
service line. Check for leaks.  Allow water 
to run for several minutes to clear line and 
system of air and any loose materials. 
Please note that for the first few days 
you may see entrapped air bubbles within 
the water. This is perfectly normal and 
will cease after the unit has processed 
several gallons of water. Also, some black 
“fines” from inside of cartridge may flow 
with the first few gallons of water. These 
are harmless, if consumed, or may be 
discarded.   

Inlet Line 

connects 

to cold water 

supply

Outlet Line 

connects to 

the faucet

Figure 

7

8.  Install Residential Mounting Bracket  

(Fig. 7)

 or  Clip Mounting Bracket            

(Fig. 8)

. Position  Mounting Bracket on 

the inside wall of the sink cabinet. Use the 
Self-Tapping Screws to securely install the 
Bracket. Make sure the Bracket location 
permits access to the cold water valve 
location and easy access for Cartridge 
changes.   

Figure 

8

Seagull IV systems are intended to be 
installed in the cold water supply line, 
downstream of and above the cold water 
shut-off valve inside the kitchen sink cabinet 
(see pages 2 and 3). If pressure surges are a 
possibility (municipal water supplies), install 
a Pressure Regulator or Surge Protector on 
the cold water supply line. Be sure to close 
supply valves before installation. The cold 
water supply line should be clean and free 
of construction debris. 
For Seagull IV X-1F system install an owner 
supplied Compression T in the cold water line 
to connect too the inlet port on the system. 
For Seagull IV X-1B connect an owner 
supplied hose from the cold water supply 
line to the inlet port, and a owner supplied 
hose from the outlet port to the existing 
faucet.

General Ecology, Inc. — 5

Inlet Line

Outlet Line

Figure 

9

Figure 

10

insert here

Installation of SEAGULL IV X-1F & X-1B Systems

water flow - in from 

cold water supply

water flow - out

to faucet

Содержание SEAGULL IV X-1F

Страница 1: ...ossibility municipal water supplies install a Pressure Regulator or Surge Protector on the cold water supply line This system is intended to be installed to the cold water supply line downstream of an...

Страница 2: ...tion Cartridge 1 788000 5 X 1 Pressure Vessel 1 N A 6 Gasket Housing Dark Blue 1 710540 7 V Clamp for Housing 1 710534 No Description Qty Part No 8 Wing Nut for V Clamp 1 710032 9 Faucet FP threaded 1...

Страница 3: ...h 1 700060 3 screws RV Marine No Description Qty Part No 4 1 3 2 No Description Qty Part No 5 Gasket Housing Dark Blue 1 710540 6 V Clamp for Housing 1 710534 7 Wing Nut for V Clamp 1 710032 8 Gasket...

Страница 4: ...a d pilot hole upward a hole and then a g hole and finally the hole necessary to mount the faucet For man made and stone products consult counter top manufacturer s guidelines For stainless steel sin...

Страница 5: ...the first few days you may see entrapped air bubbles within the water This is perfectly normal and will cease after the unit has processed several gallons of water Also some black fines from inside of...

Страница 6: ...a large sauce pan or other container remove V Clamp and drain loose water from Pressure Vessel If Pressure Vessel halves remain attached due to set pull apart manually or momentarily allow a small am...

Страница 7: ...ble acting pump for more water with less work Field serviceable pump disassembles for easy cleaning and permits the X 1P water purifier to be used with gravity feed assistance systems Quick Disconnect...

Страница 8: ...mount of a non abrasive liquid detergent and a soft wet cloth Gently rub the soiled surface until the dirt is removed Then rinse clean and wipe with a dry soft cloth to remove water drops and to preve...

Отзывы: