Owner’s Manual for Portable Generator
17
Recoil Start
1. Push and hold decompression down and
slowly pull recoil starter 2 to 3 times. Do
not start engine.
2. Pull decompression lever up. Pull recoil
slowly until resistance is felt. This will
close valves so moisture cannot enter
engine cylinder. Gently release recoil.
Electric Start
1. Push and hold decompression lever down.
2. Push Start/Run/Stop switch to turn the
engine for 2 to 3 seconds. Do not start
engine.
3. Pull decompression lever up. Pull recoil
slowly until resistance is felt. This will
close valves so moisture cannot enter
engine cylinder. Gently release recoil.
4. Completely drain fuel tank or completely
fill fuel tank to proper level.
NOTE:
Always treat diesel fuel for long term
storage. Use the approved fuel additive and
water abatement material. Test stored fuel
every 90 days and provide additional treat-
ment if required. Periodically check and dry
abatement material as necessary.
Change Oil
Change engine oil before storage. See
Return Engine to Service
1. Refer to the
sec-
tion.
2. Start engine and run at no load for 5 to 10
minutes while checking:
– oil pressure
– fuel, engine oil or coolant leaks
– proper operation of indicators/gauges
NOTE:
Avoid prolonged operation at minimum
or maximum engine speeds and loads for the
first hour of operation.
Troubleshooting
PROBLEM
CAUSE
CORRECTION
Engine is running, but
AC output is not
available.
1. Circuit breaker OPEN.
2. Poor connection or defective
cord set.
3. Connected device is bad.
4. Fault in generator.
5. Main breaker switch is OFF.
6. Voltage selector switch is OFF.
7. Generator is overloaded.
8. GFCI outlet has tripped.
1. Reset circuit breaker.
2. Check and repair.
3. Connect another device that is
in good condition.
4. Contact Authorized Service
Dealer.
5. Switch main breaker ON.
6. Switch voltage selector switch
to desired voltage output.
7. See
8. Correct ground fault in circuit
and reset GFCI.
Engine runs well at
no-load, but bogs when
load is applied.
1. Short circuit in a connected
load.
2. Generator is overloaded.
3. Engine speed is too slow.
4. Shorted generator circuit.
1. Disconnect shorted electrical
load.
2. See
3. Contact Authorized Service
Dealer.
4. Contact Authorized Service
Dealer.
Содержание XD5000E
Страница 21: ...Owner s Manual for Portable Generator 19 Notes ...
Страница 22: ...20 Owner s Manual for Portable Generator ...
Страница 23: ......
Страница 46: ...Manual del propietario del generador portátil 20 Notas ...
Страница 47: ...Manual del propietario para generador portátil 21 Notas ...
Страница 48: ...Manual del propietario para generador portátil 22 Notas ...
Страница 49: ......
Страница 72: ...Manuel de l utilisateur de la génératrice portable 20 Remarques ...
Страница 73: ...Manuel de l utilisateur de la génératrice portable 21 Remarques ...
Страница 74: ...22 Manuel de l utilisateur de la génératrice portable Remarques ...
Страница 75: ......